Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-65220

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-20 Nov, 2025 | 00:00
Updated At-20 Nov, 2025 | 15:27
Rejected At-
Credits

Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:20 Nov, 2025 | 00:00
Updated At:20 Nov, 2025 | 15:27
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.md
N/A
Hyperlink: https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.md
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.14.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:20 Nov, 2025 | 15:17
Updated At:21 Nov, 2025 | 17:26

Tenda AC21 V16.03.08.16 is vulnerable to Buffer Overflow in: /goform/SetVirtualServerCfg via the list parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.14.3MEDIUM
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Type: Secondary
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>ac21_firmware>>16.03.08.16
cpe:2.3:o:tenda:ac21_firmware:16.03.08.16:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>ac21>>-
cpe:2.3:h:tenda:ac21:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-121Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-121
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.mdcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN1.md
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

595Records found

CVE-2023-45481
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.24% / 47.33%
||
7 Day CHG~0.00%
Published-29 Nov, 2023 | 00:00
Updated-05 Jun, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10_firmwareac10n/aac10
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2813
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.95%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-23 Aug, 2024 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-44018
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.55% / 88.96%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-44013
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.65%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-44015
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.22%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-44014
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.22%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-44017
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.65%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-44019
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.22%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 01:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10uac10u_firmwaren/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2025-29100
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.18% / 39.30%
||
7 Day CHG~0.00%
Published-24 Mar, 2025 | 00:00
Updated-01 Apr, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8ac8_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-44390
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-0.11% / 28.87%
||
7 Day CHG~0.00%
Published-23 Aug, 2024 | 00:00
Updated-13 Dec, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206n/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-44553
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.22% / 44.72%
||
7 Day CHG~0.00%
Published-26 Aug, 2024 | 00:00
Updated-27 Aug, 2024 | 14:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formGetIptv.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-44551
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.22% / 44.72%
||
7 Day CHG~0.00%
Published-26 Aug, 2024 | 00:00
Updated-26 Mar, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formGetIptv.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0994
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.10% / 26.53%
||
7 Day CHG~0.00%
Published-29 Jan, 2024 | 01:31
Updated-12 Nov, 2024 | 21:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6 httpd setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6w6_firmwareW6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0538
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.41%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:00
Updated-23 Oct, 2024 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd formQosManage_auto stack-based overflow

A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9w9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0531
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.13% / 33.27%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 02:00
Updated-03 Jun, 2025 | 14:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A15 Web-based Management Interface setBlackRule stack-based overflow

A vulnerability was found in Tenda A15 15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/setBlackRule of the component Web-based Management Interface. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250701 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a15a15_firmwareA15
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0536
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.41%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 03:31
Updated-17 Jun, 2025 | 21:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlAccessList stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2806
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.28%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-42985
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.31% / 53.81%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206n/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4251
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.19%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 13:00
Updated-27 Jan, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42955
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.15% / 36.24%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42968
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.15% / 36.24%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-15 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-42949
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.15% / 36.24%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-16 Aug, 2024 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-42944
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.37%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 00:00
Updated-15 Aug, 2024 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4168
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 68.19%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4164
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.41% / 60.82%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 10:31
Updated-01 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G3 ModifyPppAuthWhiteMac formModifyPppAuthWhiteMac stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-G3g3
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4115
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.15% / 35.40%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 15:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E AddDnsForward formAddDnsForward stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15E
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4171
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.50% / 65.44%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:31
Updated-15 Jul, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E WizardHandle fromWizardHandle stack-based overflow

A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4169
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.80%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 12:31
Updated-21 Jan, 2025 | 14:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4279CC stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-41465
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.31% / 53.81%
||
7 Day CHG~0.00%
Published-24 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201n/afh1201_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-41492
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.19% / 41.11%
||
7 Day CHG~0.00%
Published-19 Jul, 2024 | 00:00
Updated-07 Apr, 2025 | 17:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack overflow in Tenda AX1806 v1.0.0.1 allows attackers to cause a Denial of Service (DoS) via a crafted input.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1806_firmwaren/aax1806_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3881
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.67%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 19:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3905
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.99% / 76.51%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3910
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3909
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.46%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:31
Updated-07 Feb, 2025 | 01:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 execCommand formexeCommand stack-based overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-34942
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.52% / 66.49%
||
7 Day CHG~0.00%
Published-10 May, 2024 | 12:52
Updated-04 Apr, 2025 | 14:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206fh1206_firmwaren/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32312
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.7||MEDIUM
EPSS-0.07% / 21.56%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1203f1203_firmwaren/af1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32315
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.7||MEDIUM
EPSS-0.11% / 30.42%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-02 Aug, 2024 | 02:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32317
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.25% / 48.33%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/aac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32307
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.24% / 46.24%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205fh1205_firmwaren/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30628
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.37% / 58.32%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-14 Mar, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205n/afh1205
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30636
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.12% / 31.58%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1202_firmwaref1202n/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3012
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.31%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3008
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 63.22%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:00
Updated-08 Apr, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 execCommand formexeCommand stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2976
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.67%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2979
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.75%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 14:00
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203f1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2977
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.52% / 66.45%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 13:31
Updated-15 Jan, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1203f1203_firmwareF1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2814
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.06%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 07:00
Updated-08 Aug, 2024 | 20:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2900
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.95% / 76.00%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 19:31
Updated-22 Jan, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveParentControlInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2903
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-1.01% / 76.78%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 20:31
Updated-22 Jan, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2893
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.26% / 49.26%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 16:31
Updated-22 Jan, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7ac7_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • ...
  • 10
  • 11
  • 12
  • Next
Details not found