Vulnerability Details :

CVE-2025-7350

Summary
Assigner-Rockwell
Assigner Org ID-b73dd486-f505-4403-b634-40b078b177f0
Published At-09 Sep, 2025 | 12:53
Updated At-09 Sep, 2025 | 13:21
Rejected At-
Credits

Rockwell Automation Stratix® IOS Cross-Site Request Forgery to Code Execution Vulnerability

A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:Rockwell
Assigner Org ID:b73dd486-f505-4403-b634-40b078b177f0
Published At:09 Sep, 2025 | 12:53
Updated At:09 Sep, 2025 | 13:21
Rejected At:
▼CVE Numbering Authority (CNA)
Rockwell Automation Stratix® IOS Cross-Site Request Forgery to Code Execution Vulnerability

A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.

Affected Products
Vendor
Rockwell Automation, Inc.Rockwell Automation
Product
Stratix IOS
Default Status
unaffected
Versions
Affected
  • 15.2(8)E5 and below
Problem Types
TypeCWE IDDescription
CWECWE-74CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Type: CWE
CWE ID: CWE-74
Description: CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Metrics
VersionBase scoreBase severityVector
4.08.6HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 4.0
Base score: 8.6
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1745.html
N/A
Hyperlink: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1745.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:PSIRT@rockwellautomation.com
Published At:09 Sep, 2025 | 13:15
Updated At:09 Sep, 2025 | 16:28

A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.6HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 4.0
Base score: 8.6
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-74SecondaryPSIRT@rockwellautomation.com
CWE ID: CWE-74
Type: Secondary
Source: PSIRT@rockwellautomation.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1745.htmlPSIRT@rockwellautomation.com
N/A
Hyperlink: https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1745.html
Source: PSIRT@rockwellautomation.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1Records found

CVE-2017-6015
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.05% / 17.12%
||
7 Day CHG~0.00%
Published-11 May, 2018 | 13:00
Updated-16 Sep, 2024 | 21:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

Action-Not Available
Vendor-Rockwell Automation, Inc.
Product-factorytalk_activationFactoryTalk Activation
CWE ID-CWE-428
Unquoted Search Path or Element
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Details not found