Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-7416

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-10 Jul, 2025 | 21:32
Updated At-11 Jul, 2025 | 16:49
Rejected At-
Credits

Tenda O3V2 httpd setSysTimeInfo fromSysToolTime stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:10 Jul, 2025 | 21:32
Updated At:11 Jul, 2025 | 16:49
Rejected At:
▼CVE Numbering Authority (CNA)
Tenda O3V2 httpd setSysTimeInfo fromSysToolTime stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
O3V2
Modules
  • httpd
Versions
Affected
  • 1.0.0.12(3880)
Problem Types
TypeCWE IDDescription
CWECWE-121Stack-based Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-121
Description: Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
pjq123 (VulDB User)
Timeline
EventDate
Advisory disclosed2025-07-10 00:00:00
VulDB entry created2025-07-10 02:00:00
VulDB entry last update2025-07-10 09:54:07
Event: Advisory disclosed
Date: 2025-07-10 00:00:00
Event: VulDB entry created
Date: 2025-07-10 02:00:00
Event: VulDB entry last update
Date: 2025-07-10 09:54:07
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.315876
vdb-entry
technical-description
https://vuldb.com/?ctiid.315876
signature
permissions-required
https://vuldb.com/?submit.608857
third-party-advisory
https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md
related
https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md#poc
exploit
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.315876
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.315876
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.608857
Resource:
third-party-advisory
Hyperlink: https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md
Resource:
related
Hyperlink: https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md#poc
Resource:
exploit
Hyperlink: https://www.tenda.com.cn/
Resource:
product
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:10 Jul, 2025 | 22:15
Updated At:16 Jul, 2025 | 15:00

A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>o3_firmware>>1.0.0.12\(3880\)
cpe:2.3:o:tenda:o3_firmware:1.0.0.12\(3880\):*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>o3>>2.0
cpe:2.3:h:tenda:o3:2.0:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-121Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-121
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.mdcna@vuldb.com
Exploit
Third Party Advisory
https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md#poccna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.315876cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.315876cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.608857cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
Hyperlink: https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://github.com/wudipjq/my_vuln/blob/main/Tenda3/vuln_49/49.md#poc
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.315876
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.315876
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.608857
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

1735Records found

CVE-2024-2852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.13% / 32.44%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 04:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2708
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.37%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:31
Updated-12 Dec, 2024 | 17:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U execCommand formexeCommand stack-based overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2987
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 63.81%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 GetParentControlInfo stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.49% / 65.73%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:00
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5080
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.18% / 78.93%
||
7 Day CHG~0.00%
Published-22 May, 2025 | 15:00
Updated-20 Jun, 2025 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 webExcptypemanFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451_firmwarefh451FH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6111
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 07:00
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4168
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.47% / 64.89%
||
7 Day CHG+0.12%
Published-25 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 14:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_4260F0 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6113
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 08:00
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 AdvSetLanip fromadvsetlanip buffer overflow

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. Affected is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-6112
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 07:31
Updated-18 Jul, 2025 | 12:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 AdvSetLanip fromadvsetlanip buffer overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7. This issue affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205fh1205_firmwareFH1205
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-2140
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.04% / 12.21%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 07:02
Updated-23 Feb, 2026 | 09:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 setMacFilterCfg sub_4223E0 buffer overflow

A vulnerability was identified in Tenda TX9 up to 22.03.02.10_multi. Affected by this issue is the function sub_4223E0 of the file /goform/setMacFilterCfg. Such manipulation of the argument deviceList leads to buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_firmwaretx9TX9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4354
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.42% / 80.82%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 12:31
Updated-13 May, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda DAP-1520 storage check_dws_cookie stack-based overflow

A vulnerability was found in Tenda DAP-1520 1.10B04_BETA02 and classified as critical. Affected by this issue is the function check_dws_cookie of the file /storage. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.D-Link Corporation
Product-dap-1520_firmwaredap-1520DAP-1520
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-6110
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.90% / 75.84%
||
7 Day CHG~0.00%
Published-16 Jun, 2025 | 06:31
Updated-17 Jun, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SafeMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201fh1201_firmwareFH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2808
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.77% / 73.71%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:00
Updated-12 Aug, 2024 | 13:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 QuickIndex formQuickIndex stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4125
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.73%
||
7 Day CHG+0.11%
Published-24 Apr, 2024 | 19:00
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E setStaticRoute formSetStaticRoute stack-based overflow

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4238
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.58%
||
7 Day CHG+0.02%
Published-26 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1806 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ax1806_firmwareax1806AX1806
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2807
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.77% / 73.71%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-10 Apr, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 expandDlnaFile formExpandDlnaFile stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2810
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.57%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiWpsOOB formWifiWpsOOB stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2806
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.81%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 04:31
Updated-21 Aug, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 addWifiMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4118
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.04%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 16:31
Updated-15 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E addIpMacBind formIPMacBindAdd stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4236
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-2.02% / 83.95%
||
7 Day CHG+0.12%
Published-26 Apr, 2024 | 17:31
Updated-01 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AX1803ax1803
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4124
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.16% / 36.45%
||
7 Day CHG~0.00%
Published-24 Apr, 2024 | 18:31
Updated-15 Jan, 2025 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4170
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 58.31%
||
7 Day CHG~0.00%
Published-25 Apr, 2024 | 13:00
Updated-21 Jan, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda 4G300 sub_429A30 stack-based overflow

A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-4g300_firmware4g3004G3004g300_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4126
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.73%
||
7 Day CHG+0.11%
Published-24 Apr, 2024 | 19:31
Updated-15 Jan, 2025 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W15E SetSysTimeCfg formSetSysTime stack-based overflow

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w15e_firmwarew15eW15Ew15e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4171
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.11%
||
7 Day CHG+0.02%
Published-25 Apr, 2024 | 13:31
Updated-15 Jul, 2025 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E WizardHandle fromWizardHandle stack-based overflow

A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30E
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-4111
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.21% / 42.75%
||
7 Day CHG+0.01%
Published-24 Apr, 2024 | 14:00
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetLEDCfg sub_42BD7C stack-based overflow

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2488
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.04%
||
7 Day CHG~0.00%
Published-15 Mar, 2024 | 09:00
Updated-14 Jan, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetPptpServerCfg formSetPPTPServer stack-based overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18ac18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4065
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.48% / 65.19%
||
7 Day CHG+0.13%
Published-23 Apr, 2024 | 20:00
Updated-21 Jan, 2025 | 19:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4066
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.49% / 65.64%
||
7 Day CHG+0.13%
Published-23 Apr, 2024 | 21:00
Updated-21 Jan, 2025 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4064
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.51% / 66.48%
||
7 Day CHG+0.13%
Published-23 Apr, 2024 | 20:00
Updated-21 Jan, 2025 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4112
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.70%
||
7 Day CHG+0.02%
Published-24 Apr, 2024 | 14:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda TX9 SetVirtualServerCfg sub_42CB94 stack-based overflow

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-tx9_pro_firmwaretx9_proTX9tx9_pro_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3909
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.58%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:31
Updated-07 Feb, 2025 | 01:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 execCommand formexeCommand stack-based overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3876
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 58.31%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3910
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.46% / 64.50%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:00
Updated-21 Jan, 2025 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3882
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 57.16%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 20:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E fromRouteStatic stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3877
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.47% / 64.89%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 18:31
Updated-21 Jan, 2025 | 16:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 fromqossetting stack-based overflow

A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3905
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 68.97%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3875
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.46% / 64.50%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 18:00
Updated-21 Jan, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 Natlimit fromNatlimit stack-based overflow

A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3907
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.36% / 58.31%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:00
Updated-17 Jan, 2025 | 21:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3881
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.34% / 57.16%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 19:31
Updated-27 Jan, 2025 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow

A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3879
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.58%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E setcfm formSetCfm stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3906
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.35% / 57.81%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 10:31
Updated-21 Jan, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500ac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3874
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.19% / 41.14%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 15:31
Updated-01 Aug, 2024 | 20:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-W20Ew20e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3878
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.42% / 62.31%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 18:31
Updated-21 Jan, 2025 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f1202f1202_firmwareF1202f1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-0537
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.14% / 32.89%
||
7 Day CHG~0.00%
Published-15 Jan, 2024 | 04:00
Updated-27 Aug, 2024 | 20:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W9 httpd setWrlBasicInfo stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w9_firmwarew9W9w9_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5978
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.55% / 81.63%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 20:31
Updated-20 Jun, 2025 | 14:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 VirtualSer fromVirtualSer stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14. It has been classified as critical. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5847
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.66% / 71.40%
||
7 Day CHG~0.00%
Published-08 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 HTTP POST Request SetRemoteWebCfg formSetSafeWanWebMan stack-based overflow

A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5852
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 00:00
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 setPptpUserList formSetPPTPUserList buffer overflow

A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-5848
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-08 Jun, 2025 | 22:00
Updated-09 Jun, 2025 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 HTTP POST Request setPptpUserList formSetPPTPUserList buffer overflow

A vulnerability was found in Tenda AC15 15.03.05.19_multi and classified as critical. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-5839
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.30%
||
7 Day CHG~0.00%
Published-07 Jun, 2025 | 17:31
Updated-09 Jun, 2025 | 19:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 POST Request AdvSetLanip fromadvsetlanip buffer overflow

A vulnerability, which was classified as critical, has been found in Tenda AC9 15.03.02.13. Affected by this issue is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Handler. The manipulation of the argument lanMask leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-5862
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.89% / 75.67%
||
7 Day CHG~0.00%
Published-09 Jun, 2025 | 05:00
Updated-09 Jun, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
  • Previous
  • 1
  • 2
  • ...
  • 8
  • 9
  • 10
  • ...
  • 34
  • 35
  • Next
Details not found