Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-7788

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-18 Jul, 2025 | 15:02
Updated At-18 Jul, 2025 | 16:57
Rejected At-
Credits

Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:18 Jul, 2025 | 15:02
Updated At:18 Jul, 2025 | 16:57
Rejected At:
▼CVE Numbering Authority (CNA)
Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Affected Products
Vendor
Xuxueli
Product
xxl-job
Versions
Affected
  • 3.1.0
  • 3.1.1
Problem Types
TypeCWE IDDescription
CWECWE-78OS Command Injection
CWECWE-77Command Injection
Type: CWE
CWE ID: CWE-78
Description: OS Command Injection
Type: CWE
CWE ID: CWE-77
Description: Command Injection
Metrics
VersionBase scoreBase severityVector
4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
2.06.5N/A
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 2.0
Base score: 6.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
ZAST.AI (VulDB User)
Timeline
EventDate
Advisory disclosed2025-07-18 00:00:00
VulDB entry created2025-07-18 02:00:00
VulDB entry last update2025-07-18 09:38:54
Event: Advisory disclosed
Date: 2025-07-18 00:00:00
Event: VulDB entry created
Date: 2025-07-18 02:00:00
Event: VulDB entry last update
Date: 2025-07-18 09:38:54
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.316849
vdb-entry
technical-description
https://vuldb.com/?ctiid.316849
signature
permissions-required
https://vuldb.com/?submit.615758
third-party-advisory
https://github.com/xuxueli/xxl-job/issues/3750
exploit
issue-tracking
Hyperlink: https://vuldb.com/?id.316849
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.316849
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.615758
Resource:
third-party-advisory
Hyperlink: https://github.com/xuxueli/xxl-job/issues/3750
Resource:
exploit
issue-tracking
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:18 Jul, 2025 | 15:15
Updated At:22 Jul, 2025 | 13:06

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Secondary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Secondary
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-77Primarycna@vuldb.com
CWE-78Primarycna@vuldb.com
CWE ID: CWE-77
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/xuxueli/xxl-job/issues/3750cna@vuldb.com
N/A
https://vuldb.com/?ctiid.316849cna@vuldb.com
N/A
https://vuldb.com/?id.316849cna@vuldb.com
N/A
https://vuldb.com/?submit.615758cna@vuldb.com
N/A
Hyperlink: https://github.com/xuxueli/xxl-job/issues/3750
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?ctiid.316849
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?id.316849
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?submit.615758
Source: cna@vuldb.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

672Records found

CVE-2025-7787
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.04% / 12.20%
||
7 Day CHG~0.00%
Published-18 Jul, 2025 | 14:14
Updated-22 Jul, 2025 | 13:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Xuxueli xxl-job SampleXxlJob.java httpJobHandler server-side request forgery

A vulnerability, which was classified as critical, was found in Xuxueli xxl-job up to 3.1.1. Affected is the function httpJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to server-side request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Xuxueli
Product-xxl-job
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2025-7932
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.04% / 76.46%
||
7 Day CHG+0.20%
Published-21 Jul, 2025 | 17:02
Updated-22 Jul, 2025 | 13:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑817L ssdpcgi lxmldbc_system command injection

A vulnerability classified as critical has been found in D-Link DIR‑817L up to 1.04B01. This affects the function lxmldbc_system of the file ssdpcgi. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR‑817L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8818
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-12 Aug, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8827
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9090
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-9.02% / 92.29%
||
7 Day CHG-5.27%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-1468
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-0.67% / 70.41%
||
7 Day CHG~0.00%
Published-08 Aug, 2016 | 00:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The administrative web interface in Cisco TelePresence Video Communication Server Expressway X8.5.2 allows remote authenticated users to execute arbitrary commands via crafted fields, aka Bug ID CSCuv12531.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-telepresence_video_communication_servern/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2011-3178
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
ShareView Details
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
CVSS Score-8.1||HIGH
EPSS-0.33% / 55.48%
||
7 Day CHG~0.00%
Published-20 Mar, 2018 | 18:00
Updated-16 Sep, 2024 | 20:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
openbuildservice webui code injection

In the web ui of the openbuildservice before 2.3.0 a code injection of the project rebuildtimes statistics could be used by authorized attackers to execute shellcode.

Action-Not Available
Vendor-openSUSE
Product-open_build_serviceopenbuildservice
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2025-9387
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.86% / 74.03%
||
7 Day CHG~0.00%
Published-24 Aug, 2025 | 12:02
Updated-25 Aug, 2025 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DCN DCME-720 Web Management Backend ip_block.php os command injection

A vulnerability was found in DCN DCME-720 9.1.5.11. This affects an unknown function of the file /usr/local/www/function/audit/newstatistics/ip_block.php of the component Web Management Backend. Performing manipulation of the argument ip results in os command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used. Other products might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-DCN
Product-DCME-720
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 26.27%
||
7 Day CHG+0.02%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-9086
Matching Score-4
Assigner-Lenovo Group Ltd.
ShareView Details
Matching Score-4
Assigner-Lenovo Group Ltd.
CVSS Score-7.2||HIGH
EPSS-2.09% / 83.31%
||
7 Day CHG~0.00%
Published-16 Nov, 2018 | 14:00
Updated-05 Aug, 2024 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Legacy Server BMC Remote Command Injection

In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a privileged user to download and execute arbitrary code inside the BMC. This can only be exploited by authorized privileged users.

Action-Not Available
Vendor-Lenovo Group Limited
Product-thinkserver_rd340thinkserver_rd640_firmwarethinkserver_rd440thinkserver_td340_firmwarethinkserver_rd640thinkserver_rd340_firmwarethinkserver_rd440_firmwarethinkserver_td340ThinkServer BMC
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9149
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.87%
||
7 Day CHG~0.00%
Published-19 Aug, 2025 | 17:32
Updated-20 Aug, 2025 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-NU516U1 wireless.cgi sub_4032E4 command injection

A vulnerability was determined in Wavlink WL-NU516U1 M16U1_V240425. This impacts the function sub_4032E4 of the file /cgi-bin/wireless.cgi. This manipulation of the argument Guest_ssid causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-WL-NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8937
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.18% / 88.25%
||
7 Day CHG+1.01%
Published-14 Aug, 2025 | 04:32
Updated-15 Aug, 2025 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N350R formSysCmd command injection

A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-N350R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8823
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 01:05
Updated-12 Aug, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setDeviceName os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8829
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:02
Updated-12 Aug, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2812
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-6.18% / 90.46%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WriteFacMac formWriteFacMac os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38470
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.1||CRITICAL
EPSS-0.37% / 58.00%
||
7 Day CHG~0.00%
Published-19 Oct, 2021 | 12:10
Updated-17 Sep, 2024 | 00:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
InHand Networks IR615 Router

InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a ping tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir615_firmwareir615IR615 Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-38520
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.6||MEDIUM
EPSS-0.26% / 49.20%
||
7 Day CHG-0.10%
Published-11 Aug, 2021 | 00:02
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R6400 before 1.0.1.52, R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, and R7000P before 1.3.2.124.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6900_firmwarer6700r6400r6400_firmwarer6700_firmwarer6900r7000pr7000p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38478
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.1||CRITICAL
EPSS-0.37% / 58.00%
||
7 Day CHG~0.00%
Published-19 Oct, 2021 | 12:11
Updated-17 Sep, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
InHand Networks IR615 Router

InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a traceroute tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir615_firmwareir615IR615 Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-7826
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 76.63%
||
7 Day CHG-0.06%
Published-22 May, 2019 | 19:33
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8665
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.87%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 17:02
Updated-06 Aug, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agno-agi agno Model Context Protocol mcp.py MultiMCPTools os command injection

A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-agno-agi
Product-agno
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-2056
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-60.26% / 98.20%
||
7 Day CHG~0.00%
Published-13 Apr, 2016 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

xymond in Xymon 4.1.x, 4.2.x, and 4.3.x before 4.3.25 allow remote authenticated users to execute arbitrary commands via shell metacharacters in the adduser_name argument in (1) web/useradm.c or (2) web/chpasswd.c.

Action-Not Available
Vendor-xymonn/aDebian GNU/Linux
Product-debian_linuxxymonn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8828
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:32
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 ipv6cmd os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.87%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 19:32
Updated-22 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaticRoute os command injection

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE9000RE6250RE6350RE6300RE6500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2010-3752
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.65% / 69.85%
||
7 Day CHG~0.00%
Published-05 Oct, 2010 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

programs/pluto/xauth.c in the client in Openswan 2.6.25 through 2.6.28 allows remote authenticated gateways to execute arbitrary commands via shell metacharacters in (1) cisco_dns_info or (2) cisco_domain_info data in a packet, a different vulnerability than CVE-2010-3302.

Action-Not Available
Vendor-xelerancen/a
Product-openswann/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-11022
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.73% / 87.52%
||
7 Day CHG~0.00%
Published-23 Mar, 2020 | 14:17
Updated-06 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR Prosafe WC9500 5.1.0.17, WC7600 5.1.0.17, and WC7520 2.5.0.35 devices allow a remote attacker to execute code with root privileges via shell metacharacters in the reqMethod parameter to login_handler.php.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-prosafe_wc7600_firmwareprosafe_wc7520_firmwareprosafe_wc9500prosafe_wc7600prosafe_wc9500_firmwareprosafe_wc7520n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8697
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.87%
||
7 Day CHG~0.00%
Published-07 Aug, 2025 | 19:02
Updated-07 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agentUniverse MCPSessionManager/MCPTool/MCPToolkit StdioServerParameters os command injection

A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/a
Product-agentUniverse
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8830
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:32
Updated-11 Aug, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setWan sub_3517C os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE6250RE7000RE6500RE9000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-6021
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.55% / 67.07%
||
7 Day CHG~0.00%
Published-09 May, 2018 | 21:00
Updated-16 Sep, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Silex SD-320AN version 2.01 and prior and GE MobileLink(GEH-SD-320AN) version GEH-1.1 and prior have a system call parameter that is not properly sanitized, which may allow remote code execution.

Action-Not Available
Vendor-silextechnologyn/a
Product-geh-sd-320an_firmwaregeh-sd-320ansd-320an_firmwaresd-320ann/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8825
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 02:02
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8821
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.33%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 00:02
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasic os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7525
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.02% / 86.08%
||
7 Day CHG~0.00%
Published-13 Jul, 2025 | 09:32
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setTracerouteCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-1141
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-4.7||MEDIUM
EPSS-0.54% / 66.55%
||
7 Day CHG~0.00%
Published-30 Jan, 2016 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

KDDI HOME SPOT CUBE devices before 2 allow remote authenticated users to execute arbitrary OS commands via unspecified vectors.

Action-Not Available
Vendor-kddin/a
Product-home_spot_cubehome_spot_cube_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7836
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.04% / 76.46%
||
7 Day CHG+0.20%
Published-19 Jul, 2025 | 16:44
Updated-22 Jul, 2025 | 13:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816L Environment Variable cgibin lxmldbc_system command injection

A vulnerability has been found in D-Link DIR-816L up to 2.06B01 and classified as critical. Affected by this vulnerability is the function lxmldbc_system of the file /htdocs/cgibin of the component Environment Variable Handler. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-816L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.55%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-0646
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.77% / 72.44%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 13:26
Updated-25 Nov, 2024 | 16:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
dst-admin cavesConsole command injection

A vulnerability classified as critical was found in dst-admin 1.5.0. Affected by this vulnerability is an unknown functionality of the file /home/cavesConsole. The manipulation of the argument command leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-220033 was assigned to this vulnerability.

Action-Not Available
Vendor-dst-admin_projectn/a
Product-dst-admindst-admin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.19%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-0647
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.77% / 72.44%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 13:27
Updated-02 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
dst-admin kickPlayer command injection

A vulnerability, which was classified as critical, has been found in dst-admin 1.5.0. Affected by this issue is some unknown functionality of the file /home/kickPlayer. The manipulation of the argument userId leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-220034 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-dst-admin_projectn/a
Product-dst-admindst-admin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7192
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.83%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 19:32
Updated-14 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-645 ssdpcgi cgibin ssdpcgi_main command injection

A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-645_firmwaredir-645DIR-645
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0649
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.77% / 72.44%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 13:33
Updated-26 Mar, 2025 | 14:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
dst-admin sendBroadcast command injection

A vulnerability has been found in dst-admin 1.5.0 and classified as critical. This vulnerability affects unknown code of the file /home/sendBroadcast. The manipulation of the argument message leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220036.

Action-Not Available
Vendor-dst-admin_projectn/a
Product-dst-admindst-admin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0648
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.77% / 72.44%
||
7 Day CHG~0.00%
Published-02 Feb, 2023 | 13:29
Updated-02 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
dst-admin masterConsole command injection

A vulnerability, which was classified as critical, was found in dst-admin 1.5.0. This affects an unknown part of the file /home/masterConsole. The manipulation of the argument command leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-220035.

Action-Not Available
Vendor-dst-admin_projectn/a
Product-dst-admindst-admin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-10322
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-10 Apr, 2017 | 18:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Synology Photo Station before 6.3-2958 allows remote authenticated guest users to execute arbitrary commands via shell metacharacters in the X-Forwarded-For HTTP header to photo/login.php.

Action-Not Available
Vendor-n/aSynology, Inc.
Product-photo_stationn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8667
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.87%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 18:02
Updated-06 Aug, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SkyworkAI DeepResearchAgent tools.py from_mcp os command injection

A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-SkyworkAI
Product-DeepResearchAgent
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-1000
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.82% / 73.43%
||
7 Day CHG~0.00%
Published-27 Apr, 2024 | 09:00
Updated-02 Aug, 2024 | 05:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
cyanomiko dcnnt-py Notification notifications.py main command injection

A vulnerability was found in cyanomiko dcnnt-py up to 0.9.0. It has been classified as critical. Affected is the function main of the file dcnnt/plugins/notifications.py of the component Notification Handler. The manipulation leads to command injection. It is possible to launch the attack remotely. Upgrading to version 0.9.1 is able to address this issue. The patch is identified as b4021d784a97e25151a5353aa763a741e9a148f5. It is recommended to upgrade the affected component. VDB-262230 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-cyanomiko
Product-dcnnt-py
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 70.83%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 13:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formSetWanStatic os command injection

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-4021
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-86.45% / 99.37%
||
7 Day CHG~0.00%
Published-03 Dec, 2018 | 22:00
Updated-17 Sep, 2024 | 03:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_battery_mode` POST parameter.

Action-Not Available
Vendor-netgateNetgate
Product-pfsenseNetgate pfSense
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-7825
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 76.63%
||
7 Day CHG-0.06%
Published-22 May, 2019 | 19:32
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7415
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.55%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 21:02
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd getTraceroute fromTraceroutGet command injection

A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-0830
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-38.96% / 97.16%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 16:13
Updated-01 May, 2025 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EasyNAS backup.pl system os command injection

A vulnerability classified as critical has been found in EasyNAS 1.1.0. Affected is the function system of the file /backup.pl. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component.

Action-Not Available
Vendor-easynasn/a
Product-easynasEasyNAS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-0935
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.87% / 74.25%
||
7 Day CHG~0.00%
Published-21 Feb, 2023 | 09:19
Updated-12 Mar, 2025 | 13:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DolphinPHP Incomplete Fix CVE-2021-46097 common.php os command injection

A vulnerability was found in DolphinPHP up to 1.5.1. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file common.php of the component Incomplete Fix CVE-2021-46097. The manipulation of the argument id leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-221551.

Action-Not Available
Vendor-dolphinphp_projectn/a
Product-dolphinphpDolphinPHP
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-4020
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-85.97% / 99.34%
||
7 Day CHG~0.00%
Published-03 Dec, 2018 | 22:00
Updated-16 Sep, 2024 | 21:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_ac_mode` POST parameter parameter.

Action-Not Available
Vendor-netgateNetgate
Product-pfsenseNetgate pfSense
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 13
  • 14
  • Next
Details not found