A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in TOTOLINK X15 1.0.0-B20230714.1105 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formFilter of the component HTTP POST Request Handler. The manipulation of the argument ip6addr/url/vpnPassword/vpnUser leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DIR-513 1.0. It has been rated as critical. Affected by this issue is the function sprintf of the file /goform/formLanSetupRouterSettings of the component Boa Webserver. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in Shenzhen Libituo Technology LBT-T300-T310 2.2.3.6. It has been rated as critical. Affected by this issue is the function sub_40B6F0 of the file at/appy.cgi. The manipulation of the argument wan_proto leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this vulnerability is the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in D-Link DI-8100 1.0. This vulnerability affects the function sprintf of the file /upnp_ctrl.asp of the component jhttpd. The manipulation of the argument remove_ext_proto/remove_ext_port leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this issue is the function fromPingResultGet of the file /goform/setPing of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. Affected is the function updateWifiInfo of the component MQTT Service. The manipulation of the argument serverIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH1201 1.2.0.14. It has been declared as critical. This vulnerability affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP POST Request Handler. The manipulation of the argument mit_ssid leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC6 15.03.06.50 and classified as critical. Affected by this vulnerability is the function setparentcontrolinfo of the component httpd. The manipulation leads to buffer overflow. The attack can be launched remotely.
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been classified as critical. This affects an unknown part of the file /menu_nat.asp of the component HTTP Request Handler. The manipulation of the argument out_addr/in_addr/out_port/proto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH451 1.0.0.9. It has been rated as critical. This issue affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
A vulnerability was found in Tenda AC1206 15.03.06.23. It has been rated as critical. This issue affects the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been rated as critical. Affected by this issue is some unknown functionality of the file /boafrm/formRoute of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in UTT HiPER 840G up to 3.1.1-190328. This affects an unknown part of the file /goform/aspApBasicConfigUrcp. The manipulation of the argument Username leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748_B20211015. This vulnerability affects the function tcpcheck_net of the file /router/meshSlaveDlfw of the component MQTT Packet Handler. The manipulation of the argument serverIp leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK A702R 4.0.0-B20230721.1521. It has been declared as critical. This vulnerability affects unknown code of the file /boafrm/formWlanMultipleAP of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda FH451 up to 1.0.0.9 and classified as critical. Affected by this issue is the function fromAddressNat of the file /goform/addressNat of the component POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). Affected by this vulnerability is the function formWifiMacFilterSet of the file /goform/setWrlFilterList of the component httpd. The manipulation of the argument macList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in TOTOLINK A702R 4.0.0-B20230721.1521. Affected is an unknown function of the file /boafrm/formFilter of the component HTTP POST Request Handler. The manipulation of the argument ip6addr leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). Affected by this issue is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument Username leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. Affected is the function formWlanMP of the file /goform/formWlanMP of the component webs. The manipulation of the argument ateFunc/ateGain/ateTxCount/ateChan/ateRate/ateMacID/e2pTxPower1/e2pTxPower2/e2pTxPower3/e2pTxPower4/e2pTxPower5/e2pTxPower6/e2pTxPower7/e2pTx2Power1/e2pTx2Power2/e2pTx2Power3/e2pTx2Power4/e2pTx2Power5/e2pTx2Power6/e2pTx2Power7/ateTxFreqOffset/ateMode/ateBW/ateAntenna/e2pTxFreqOffset/e2pTxPwDeltaB/e2pTxPwDeltaG/e2pTxPwDeltaMix/e2pTxPwDeltaN/readE2P leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in Belkin F9K1122 1.00.33. Affected by this issue is the function formConnectionSetting of the file /goform/formConnectionSetting of the component webs. The manipulation of the argument max_Conn/timeOut leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Belkin F9K1122 1.00.33. It has been rated as critical. This issue affects the function formiNICWpsStart of the file /goform/formiNICWpsStart of the component webs. The manipulation of the argument pinCode leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Stack-based buffer overflow in NWFTPD.NLM before 5.10.02 in the FTP server in Novell NetWare allows remote authenticated users to execute arbitrary code or cause a denial of service (abend) via a long DELE command, a different vulnerability than CVE-2010-0625.4.
A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in TOTOLINK X15 up to 1.0.0-B20230714.1105. Affected is an unknown function of the file /boafrm/formParentControl of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Tenda F453 1.0.0.3. Affected by this issue is the function frmL7ProtForm of the file /goform/L7Prot of the component httpd. Performing a manipulation of the argument page results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Linksys E8450 up to 1.2.00.360516. This affects the function set_device_language of the file portal.cgi of the component HTTP POST Request Handler. The manipulation of the argument dut_language leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability in web-based management interface of Cisco Small Business RV340 and RV345 Routers could allow an authenticated, remote attacker to execute arbitrary code on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending malicious input to an affected device. A successful exploit could allow the attacker to execute remote code on the affected device. To exploit this vulnerability, an attacker would need to have valid Administrator credentials on the affected device.
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.