Hydra is a Continuous Integration service for Nix based projects. It is possible to trigger evaluations in Hydra without any authentication. Depending on the size of evaluations, this can impact the availability of systems. The problem can be fixed by applying https://github.com/NixOS/hydra/commit/f73043378907c2c7e44f633ad764c8bdd1c947d5 to any Hydra package. Users are advised to upgrade. Users unable to upgrade should deny the `/api/push` route in a reverse proxy. This also breaks the "Evaluate jobset" button in the frontend.
Hydra is a continuous integration service for Nix based projects. Prior to commit f7bda02, /api/push-github and /api/push-gitea are called by the corresponding forge without HTTP Basic authentication. Both forges do however feature HMAC signing with a secret key. Triggering an evaluation can be very taxing on the infrastructure when large evaluations are done, introducing potential denial of service attacks on the host running the evaluator. This issue has been patched by commit f7bda02. A workaround involves blocking /api/push-github and /api/push-gitea via a reverse proxy.
Missing authentication in the SetDB method in IDAttend’s IDWeb application 3.1.052 and earlier allows denial of service or theft of database login credentials.
An access control issue in Ecowitt GW1100 Series Weather Stations <=GW1100B_v2.1.5 allows unauthenticated attackers to access sensitive information including device and local WiFi passwords.
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
An issue was discovered in URVE Build 24.03.2020. Using the _internal/pc/shutdown.php path, it is possible to shutdown the system. Among others, the following files and scripts are also accessible: _internal/pc/abort.php, _internal/pc/restart.php, _internal/pc/vpro.php, _internal/pc/wake.php, _internal/error_u201409.txt, _internal/runcmd.php, _internal/getConfiguration.php, ews/autoload.php, ews/del.php, ews/mod.php, ews/sync.php, utils/backup/backup_server.php, utils/backup/restore_server.php, MyScreens/timeline.config, kreator.html5/test.php, and addedlogs.txt.
A change introduced in Apache Flink 1.11.0 (and released in 1.11.1 and 1.11.2 as well) allows attackers to read any file on the local filesystem of the JobManager through the REST interface of the JobManager process. Access is restricted to files accessible by the JobManager process. All users should upgrade to Flink 1.11.3 or 1.12.0 if their Flink instance(s) are exposed. The issue was fixed in commit b561010b0ee741543c3953306037f00d7a9f0801 from apache/flink:master.
Sing-box is an open source proxy system. Affected versions are subject to an authentication bypass when specially crafted requests are sent to sing-box. This affects all SOCKS5 inbounds with user authentication and an attacker may be able to bypass authentication. Users are advised to update to sing-box 1.4.4 or to 1.5.0-rc.4. Users unable to update should not expose the SOCKS5 inbound to insecure environments.
Sharp and Toshiba Tec MFPs improperly process HTTP authentication requests, resulting in an authentication bypass vulnerability.