Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. Prior to versions 4.10.11 and 5.2.2, the certificate in the Parse Server Apple Game Center auth adapter not validated. As a result, authentication could potentially be bypassed by making a fake certificate accessible via certain Apple domains and providing the URL to that certificate in an authData object. Versions 4.0.11 and 5.2.2 prevent this by introducing a new `rootCertificateUrl` property to the Parse Server Apple Game Center auth adapter which takes the URL to the root certificate of Apple's Game Center authentication certificate. If no value is set, the `rootCertificateUrl` property defaults to the URL of the current root certificate as of May 27, 2022. Keep in mind that the root certificate can change at any time and that it is the developer's responsibility to keep the root certificate URL up-to-date when using the Parse Server Apple Game Center auth adapter. There are no known workarounds for this issue.
A security vulnerability exists in the Zingbox Inspector versions 1.280 and earlier, where authentication is not required when binding the Inspector instance to a different customer tenant.
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable front panel authentication via crafted HTTP requests.
Apache Hive before 3.1.3 "CREATE" and "DROP" function operations does not check for necessary authorization of involved entities in the query. It was found that an unauthorized user can manipulate an existing UDF without having the privileges to do so. This allowed unauthorized or underprivileged users to drop and recreate UDFs pointing them to new jars that could be potentially malicious.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable front panel authentication via crafted HTTP requests.
ONLYOFFICE all versions as of 2021-11-08 is affected by Incorrect Access Control. An authentication bypass in the document editor allows attackers to edit documents without authentication.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device.
ESPHome is a system to control the ESP8266/ESP32. Anyone with web_server enabled and HTTP basic auth configured on version 2021.9.1 or older is vulnerable to an issue in which `web_server` allows over-the-air (OTA) updates without checking user defined basic auth username & password. This issue is patched in version 2021.9.2. As a workaround, one may disable or remove `web_server`.
Gnuboard 5.5.4 and 5.5.5 is vulnerable to Insecure Permissions. An attacker can change password of all users without knowing victim's original password.
On all 7.x and 6.x versions (fixed in 8.0.0), BIG-IQ high availability (HA) when using a Quorum device for automatic failover does not implement any form of authentication with the Corosync daemon. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
The web interface on the RIGOL MSO5000 digital oscilloscope with firmware 00.01.03.00.03 allows remote attackers to change the admin password via a zero-length pass0 to the webcontrol changepwd.cgi application, i.e., the entered password only needs to match the first zero characters of the saved password.
Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors.
IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
Yoke is a Helm-inspired infrastructure-as-code (IaC) package deployer. In 0.19.0 and earlier, a vulnerability exists in the Air Traffic Controller (ATC) component of Yoke. The ATC webhook endpoints lack proper authentication mechanisms, allowing any pod within the cluster network to directly send AdmissionReview requests to the webhook, bypassing Kubernetes API Server authentication. This enables attackers to trigger WASM module execution in the ATC controller context without proper authorization.
VDSM and libvirt in Red Hat Enterprise Virtualization Hypervisor (aka RHEV-H) 7-7.x before 7-7.2-20151119.0 and 6-6.x before 6-6.7-20151117.0 as packaged in Red Hat Enterprise Virtualization before 3.5.6 when VSDM is run with -spice disable-ticketing and a VM is suspended and then restored, allows remote attackers to log in without authentication via unspecified vectors.
PolarLearn is a free and open-source learning program. In 0-PRERELEASE-16 and earlier, the group chat WebSocket at wss://polarlearn.nl/api/v1/ws can be used without logging in. An unauthenticated client can subscribe to any group chat by providing a group UUID, and can also send messages to any group. The server accepts the message and stores it in the group’s chatContent, so this is not just a visual spam issue.
An issue was discovered on D-Link DSL-2640B E1 EU_1.01 devices. The administrative interface doesn't perform authentication checks for a firmware-update POST request. Any attacker that can access the administrative interface can install firmware of their choice.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
Lexmark products through 2022-02-10 have Incorrect Access Control.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device via ssh.
In JetBrains YouTrack before 2025.1.76253 deletion of issues was possible due to missing permission checks in API
FOG is a free open-source cloning/imaging/rescue suite/inventory management system. Versions 1.5.10.1673 and below contain an authentication bypass vulnerability. It is possible for an attacker to perform an unauthenticated DB dump where they could pull a full SQL DB without credentials. A fix is expected to be released 9/15/2025. To address this vulnerability immediately, upgrade to the latest version of either the dev-branch or working-1.6 branch. This will patch the issue for users concerned about immediate exposure. See the FOG Project documentation for step-by-step upgrade instructions: https://docs.fogproject.org/en/latest/install-fog-server#choosing-a-fog-version.
Talend Data Catalog remote harvesting server before 8.0-20230413 contains a /upgrade endpoint that allows an unauthenticated WAR file to be deployed on the server. (A mitigation is that the remote harvesting server should be behind a firewall that only allows access to the Talend Data Catalog server.)
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable an authentication profile server via crafted HTTP requests.
Missing authentication in the SetStudentNotes method in IDAttend’s IDWeb application 3.1.052 and earlier allows modification of student data by unauthenticated attackers.
Apollo is a configuration management system. Prior to version 2.1.0, there are potential security issues if users expose apollo-configservice to the internet, which is not recommended. This is because there is no authentication feature enabled for the built-in eureka service. Malicious hackers may access eureka directly to mock apollo-configservice and apollo-adminservice. Login authentication for eureka was added in version 2.1.0. As a workaround, avoid exposing apollo-configservice to the internet.
An issue was discovered in the femanager extension before 5.5.3, 6.x before 6.3.4, and 7.x before 7.1.0 for TYPO3. Missing access checks in the InvitationController allow an unauthenticated user to delete all frontend users.
An issue was discovered in the femanager extension before 5.5.3, 6.x before 6.3.4, and 7.x before 7.1.0 for TYPO3. Missing access checks in the InvitationController allow an unauthenticated user to set the password of all frontend users.
OpenClaw is a personal AI assistant. Versions 2026.2.13 and below allow the optional @openclaw/voice-call plugin Telnyx webhook handler to accept unsigned inbound webhook requests when telnyx.publicKey is not configured, enabling unauthenticated callers to forge Telnyx events. Telnyx webhooks are expected to be authenticated via Ed25519 signature verification. In affected versions, TelnyxProvider.verifyWebhook() could effectively fail open when no Telnyx public key was configured, allowing arbitrary HTTP POST requests to the voice-call webhook endpoint to be treated as legitimate Telnyx events. This only impacts deployments where the Voice Call plugin is installed, enabled, and the webhook endpoint is reachable from the attacker (for example, publicly exposed via a tunnel/proxy). The issue has been fixed in version 2026.2.14.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
Vulnerability in the Oracle iSetup product of Oracle E-Business Suite (component: General Ledger Update Transform, Reports). Supported versions that are affected are 12.2.3-12.2.12. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle iSetup. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle iSetup accessible data. CVSS 3.1 Base Score 7.5 (Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
Missing authentication when creating and managing the B&R APROL database in versions <Â R 4.2-07 allows reading and changing the system configuration.Â
Eibiz i-Media Server Digital Signage 3.8.0 contains an authentication bypass vulnerability that allows unauthenticated attackers to create admin users through AMF-encoded object manipulation. Attackers can send crafted serialized objects to the /messagebroker/amf endpoint to create administrative users without authentication, bypassing security controls.
A vulnerability, which was classified as critical, has been found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. This issue affects the function addCrawlSource of the file novel-crawl/src/main/java/com/java2nb/novel/controller/CrawlController.java. The manipulation leads to missing authentication. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
A remote unauthenticated attacker may be able to bypass authentication by utilizing a specific API route to execute arbitrary OS commands.
An access control issue in Canaan Avalon ASIC Miner 2020.3.30 and below allows unauthenticated attackers to arbitrarily change user passwords via a crafted POST request.
The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
An issue was discovered in Couchbase Server before 7.0.4. The Index Service does not enforce authentication for TCP/TLS servers.
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
Lack of authentication vulnerability. An unauthenticated local user is able to see through the cameras using the web server due to the lack of any form of authentication.
Missing authentication on ShenYu Admin when register by HTTP. This issue affected Apache ShenYu 2.4.0 and 2.4.1.
ClickStudios Passwordstate Password Reset Portal prior to build 8501 is affected by an authentication bypass vulnerability. The ResetPassword function does not validate whether the user has successfully authenticated using security questions. An unauthenticated, remote attacker can send a crafted HTTP request to the /account/ResetPassword page to set a new password for any registered user.
The /device/acceptBind end-point for Ourphoto App version 1.4.1 does not require authentication or authorization. The user_token header is not implemented or present on this end-point. An attacker can send a request to bind their account to any users picture frame, then send a POST request to accept their own bind request, without the end-users approval or interaction.