Tenda AC8 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow

A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:23 Feb, 2026 | 23:32
Updated At:23 Feb, 2026 | 23:32
Rejected At:
â–¼CVE Numbering Authority (CNA)
Tenda AC8 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow

A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
AC8
CPEs
  • cpe:2.3:o:tenda:ac8_firmware:*:*:*:*:*:*:*:*
Modules
  • Httpd Service
Versions
Affected
  • 16.03.34.06
Problem Types
TypeCWE IDDescription
CWECWE-121Stack-based Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-121
Description: Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
942384053 (VulDB User)
Timeline
EventDate
Advisory disclosed2026-02-23 00:00:00
VulDB entry created2026-02-23 01:00:00
VulDB entry last update2026-02-23 17:54:47
Event: Advisory disclosed
Date: 2026-02-23 00:00:00
Event: VulDB entry created
Date: 2026-02-23 01:00:00
Event: VulDB entry last update
Date: 2026-02-23 17:54:47
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.347400
vdb-entry
technical-description
https://vuldb.com/?ctiid.347400
signature
permissions-required
https://vuldb.com/?submit.757240
third-party-advisory
https://github.com/master-abc/cve/issues/43
exploit
issue-tracking
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.347400
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.347400
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.757240
Resource:
third-party-advisory
Hyperlink: https://github.com/master-abc/cve/issues/43
Resource:
exploit
issue-tracking
Hyperlink: https://www.tenda.com.cn/
Resource:
product
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:24 Feb, 2026 | 00:16
Updated At:24 Feb, 2026 | 14:13

A vulnerability has been found in Tenda AC8 16.03.34.06. This affects the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. The manipulation of the argument boundary leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-121Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-121
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/master-abc/cve/issues/43cna@vuldb.com
N/A
https://vuldb.com/?ctiid.347400cna@vuldb.com
N/A
https://vuldb.com/?id.347400cna@vuldb.com
N/A
https://vuldb.com/?submit.757240cna@vuldb.com
N/A
https://www.tenda.com.cn/cna@vuldb.com
N/A
Hyperlink: https://github.com/master-abc/cve/issues/43
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?ctiid.347400
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?id.347400
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?submit.757240
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1203Records found

CVE-2025-3803
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 69.68%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 15:00
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiSysScheduleRebootSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3161
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.84% / 74.34%
||
7 Day CHG~0.00%
Published-03 Apr, 2025 | 14:31
Updated-07 Apr, 2025 | 14:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 ShutdownSetAdd stack-based overflow

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC10
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11117
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 19:32
Updated-03 Oct, 2025 | 13:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 GstDhcpSetSer formWrlExtraGet buffer overflow

A vulnerability was determined in Tenda CH22 1.0.0.1. This vulnerability affects the function formWrlExtraGet of the file /goform/GstDhcpSetSer. This manipulation of the argument dips causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11123
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.79%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 22:32
Updated-03 Oct, 2025 | 13:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 saveAutoQos stack-based overflow

A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-0566
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.07% / 77.43%
||
7 Day CHG~0.00%
Published-19 Jan, 2025 | 06:31
Updated-01 Jul, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDevNetName formSetDevNetName stack-based overflow

A vulnerability classified as critical has been found in Tenda AC15 15.13.07.13. This affects the function formSetDevNetName of the file /goform/SetDevNetName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-7707
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.60% / 69.01%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 00:00
Updated-22 Aug, 2024 | 13:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow

A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206_firmwarefh1206FH1206fh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-8229
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.69% / 71.46%
||
7 Day CHG~0.00%
Published-28 Aug, 2024 | 00:31
Updated-29 Aug, 2024 | 00:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O6 operateMacFilter frommacFilterModify stack-based overflow

A vulnerability was found in Tenda O6 1.0.0.7(2054). It has been declared as critical. This vulnerability affects the function frommacFilterModify of the file /goform/operateMacFilter. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o6_firmwareo6O6o6_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-6189
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.59% / 68.72%
||
7 Day CHG~0.00%
Published-20 Jun, 2024 | 14:00
Updated-01 Nov, 2024 | 14:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow

A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a301_firmwarea301A301a301
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10434
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.16%
||
7 Day CHG~0.00%
Published-28 Oct, 2024 | 00:31
Updated-01 Nov, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow

A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-10661
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.61% / 69.36%
||
7 Day CHG~0.00%
Published-01 Nov, 2024 | 16:00
Updated-05 Nov, 2024 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 SetDlnaCfg stack-based overflow

A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4494
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.38% / 59.18%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4493
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.38% / 59.18%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 03:00
Updated-27 Jan, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formSetAutoPing stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-4495
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.46% / 63.88%
||
7 Day CHG~0.00%
Published-05 May, 2024 | 05:31
Updated-27 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda i21 formWifiMacFilterGet stack-based overflow

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-i21i21_firmwarei21i21
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-3786
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 69.68%
||
7 Day CHG~0.00%
Published-18 Apr, 2025 | 09:00
Updated-22 Apr, 2025 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WifiExtraSet fromSetWirelessRepeat buffer overflow

A vulnerability was found in Tenda AC15 up to 15.03.05.19 and classified as critical. This issue affects the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument mac leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-15232
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.87%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 07:32
Updated-24 Feb, 2026 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setAdPushInfo formSetAdPushInfo stack-based overflow

A vulnerability was identified in Tenda M3 1.0.0.13(4903). This vulnerability affects the function formSetAdPushInfo of the file /goform/setAdPushInfo. The manipulation of the argument mac/terminal leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-1814
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.26%
||
7 Day CHG~0.00%
Published-02 Mar, 2025 | 11:00
Updated-03 Mar, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 WifiExtraSet stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC6 15.03.05.16. Affected by this issue is some unknown functionality of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC6
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15218
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.87%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 03:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U POST Request Parameter AdvSetLanip fromadvsetlanip buffer overflow

A weakness has been identified in Tenda AC10U 15.03.06.48/15.03.06.49. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip of the component POST Request Parameter Handler. Executing a manipulation of the argument lanMask can lead to buffer overflow. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10u_firmwareac10uAC10U
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-15356
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.28%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 20:32
Updated-24 Feb, 2026 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 PowerSaveSet sscanf buffer overflow

A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The impacted element is the function sscanf of the file /goform/PowerSaveSet. The manipulation of the argument powerSavingEn/time/powerSaveDelay/ledCloseType leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-15217
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 26.78%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 03:02
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 HTTP POST Request formSetPPTPUserList buffer overflow

A security flaw has been discovered in Tenda AC23 16.03.07.52. Affected is the function formSetPPTPUserList of the component HTTP POST Request Handler. Performing a manipulation of the argument list results in buffer overflow. The attack can be initiated remotely.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-1851
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.82% / 74.12%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 05:00
Updated-03 Mar, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow

A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-15234
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.87%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 08:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 setInternetLanInfo formSetRemoteInternetLanInfo heap-based overflow

A weakness has been identified in Tenda M3 1.0.0.13(4903). Impacted is the function formSetRemoteInternetLanInfo of the file /goform/setInternetLanInfo. This manipulation of the argument portIp/portMask/portGateWay/portDns/portSecDns causes heap-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2025-15216
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.87%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 02:32
Updated-24 Feb, 2026 | 06:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetIpMacBind fromSetIpMacBind stack-based overflow

A vulnerability was identified in Tenda AC23 16.03.07.52. This impacts the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument bindnum leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14992
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 26.78%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 04:02
Updated-24 Feb, 2026 | 05:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request GetParentControlInfo strcpy stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14655
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.04%
||
7 Day CHG+0.05%
Published-14 Dec, 2025 | 10:32
Updated-24 Feb, 2026 | 06:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow

A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing a manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20_firmwareac20AC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-14993
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 26.78%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 04:32
Updated-24 Feb, 2026 | 06:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 HTTP Request SetDlnaCfg sprintf stack-based overflow

A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14994
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 30.02%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 07:32
Updated-31 Dec, 2025 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow

A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1206fh1201_firmwarefh1201fh1206_firmwareFH1201FH1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-14995
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 26.78%
||
7 Day CHG~0.00%
Published-21 Dec, 2025 | 08:32
Updated-24 Feb, 2026 | 06:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1201 SetIpBind sprintf stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1201_firmwarefh1201FH1201
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-13288
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.16%
||
7 Day CHG~0.00%
Published-17 Nov, 2025 | 15:32
Updated-24 Feb, 2026 | 06:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 PPTPUserSetting fromPptpUserSetting buffer overflow

A security vulnerability has been detected in Tenda CH22 1.0.0.1. This impacts the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22_firmwarech22CH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-13400
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-19 Nov, 2025 | 17:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 WrlExtraGet formWrlExtraGet buffer overflow

A vulnerability was detected in Tenda CH22 1.0.0.1. Affected is the function formWrlExtraGet of the file /goform/WrlExtraGet. Performing a manipulation of the argument chkHz results in buffer overflow. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-13258
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.79%
||
7 Day CHG~0.00%
Published-17 Nov, 2025 | 02:02
Updated-24 Feb, 2026 | 06:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 WifiExtraSet buffer overflow

A vulnerability was detected in Tenda AC20 up to 16.03.08.12. The impacted element is an unknown function of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto results in buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12273
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 40.58%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 12:32
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 webExcptypemanFilter fromwebExcptypemanFilter buffer overflow

A weakness has been identified in Tenda CH22 1.0.0.1. Affected is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. Executing a manipulation of the argument page can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12271
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 12:02
Updated-24 Feb, 2026 | 07:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 RouteStatic fromRouteStatic buffer overflow

A vulnerability was identified in Tenda CH22 1.0.0.1. This affects the function fromRouteStatic of the file /goform/RouteStatic. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12595
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-02 Nov, 2025 | 10:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow

A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12622
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.31%
||
7 Day CHG~0.00%
Published-03 Nov, 2025 | 07:32
Updated-24 Feb, 2026 | 06:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 SysRunCmd formSysRunCmd buffer overflow

A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10_firmwareac10AC10
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12322
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.92%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 20:32
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 NatStaticSetting fromNatStaticSetting buffer overflow

A flaw has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. Executing a manipulation of the argument page can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12611
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-03 Nov, 2025 | 02:02
Updated-24 Feb, 2026 | 06:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow

A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21ac21_firmwareAC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12272
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 12:02
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 addressNat fromAddressNat buffer overflow

A security flaw has been discovered in Tenda CH22 1.0.0.1. This impacts the function fromAddressNat of the file /goform/addressNat. Performing a manipulation of the argument page results in buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-12210
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.90%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 03:02
Updated-24 Feb, 2026 | 07:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 AdvSetLanip GetValue stack-based overflow

A vulnerability was identified in Tenda O3 1.0.0.10(2478). Affected by this vulnerability is the function SetValue/GetValue of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12214
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.92%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 04:02
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3 sysAutoReboot GetValue stack-based overflow

A vulnerability was detected in Tenda O3 1.0.0.10(2478). This issue affects the function SetValue/GetValue of the file /goform/sysAutoReboot. Performing a manipulation of the argument enable results in stack-based buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmware1.0.0.10\(2478\)o3O3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-12236
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.04%
||
7 Day CHG~0.00%
Published-27 Oct, 2025 | 06:22
Updated-24 Feb, 2026 | 08:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 DhcpListClient fromDhcpListClient buffer overflow

A vulnerability was determined in Tenda CH22 1.0.0.1. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. This manipulation of the argument page causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22ch22_firmwareCH22
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-10803
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.10%
||
7 Day CHG+0.05%
Published-22 Sep, 2025 | 15:02
Updated-24 Sep, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow

A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11122
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.79%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 22:02
Updated-03 Oct, 2025 | 13:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 WizardHandle stack-based overflow

A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11327
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-06 Oct, 2025 | 08:02
Updated-24 Feb, 2026 | 06:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetUpnpCfg stack-based overflow

A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11524
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:02
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetDDNSCfg stack-based overflow

A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11356
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 07:02
Updated-24 Feb, 2026 | 06:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 SetStaticRouteCfg sscanf buffer overflow

A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23ac23_firmwareAC23
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11528
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 03:02
Updated-24 Feb, 2026 | 06:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 saveAutoQos stack-based overflow

A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11091
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.13% / 32.88%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 01:32
Updated-03 Oct, 2025 | 14:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 SetStaticRouteCfg sscanf buffer overflow

A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21ac21_firmwareAC21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11120
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.74%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 21:02
Updated-03 Oct, 2025 | 13:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetServerConfig formSetServerConfig buffer overflow

A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-11525
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.79%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:32
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 SetUpnpCfg stack-based overflow

A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11386
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.72%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 10:02
Updated-24 Feb, 2026 | 06:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 POST Parameter SetDDNSCfg stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer