Improper access control vulnerability in cloudNotificationManager.java SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via PUSH_MESSAGE_RECEIVED broadcast.
A vulnerability in corydolphin/flask-cors version 4.0.1 allows the `Access-Control-Allow-Private-Network` CORS header to be set to true by default. This behavior can expose private network resources to unauthorized external access, leading to significant security risks such as data breaches, unauthorized access to sensitive information, and potential network intrusions.
OcoMon 4.0RC1 is vulnerable to Incorrect Access Control. Through a request the user can obtain the real email, sending the same request with correct email its possible to account takeover.
Improper access control vulnerability cloudNotificationManager.java in SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via implicit broadcasts.
Improper access control vulnerability in WifiSetupLaunchHelper in SmartThings prior to version 1.7.89.25 allows attackers to access sensitive information via implicit intent.
Improper access control vulnerability in ContentsSharingActivity.java SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via implicit broadcast.
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication.
macrozheng mall-tiny 1.0.1 is vulnerable to Incorrect Access Control via the logout function. After a user logs out, their token is still available and fetches information in the logged-in state.
A security vulnerability has been detected in D-Link DIR-605L and DIR-619L 2.06B01/2.13B01. The impacted element is an unknown function of the file /wan_connection_status.asp of the component DHCP Connection Status Handler. The manipulation leads to information disclosure. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
There is an improper access control vulnerability in Portal for ArcGIS versions 10.8.1 and below which could allow a remote, unauthenticated attacker to access an API that may induce Esri Portal for ArcGIS to read arbitrary URLs.
Siklu TG Terragraph devices before 2.1.1 allow attackers to discover valid, randomly generated credentials via GetCredentials.
Incorrect access control in the preHandle function of my-site v1.0.2 allows attackers to access sensitive components without authentication via the cn.luischen.interceptor.BaseInterceptor class
kCTF is a Kubernetes-based infrastructure for capture the flag (CTF) competitions. Prior to version 1.6.0, the kctf cluster set-src-ip-ranges was broken and allowed traffic from any IP. The problem has been patched in v1.6.0. As a workaround, those who want to test challenges privately can mark them as `public: false` and use `kctf chal debug port-forward` to connect.
Incorrect access control in the component download_wb.cgi of Weintek cMT-3072XH2 easyweb Web Version v2.1.53, OS v20231011 allows unauthenticated attack to download arbitrary files.
Insufficient access controls in the AMD Link Android app may potentially result in information disclosure.
ThinkPHP Framework v5.0.24 was discovered to be configured without the PATHINFO parameter. This allows attackers to access all system environment parameters from index.php. NOTE: this is disputed by a third party because system environment exposure is an intended feature of the debugging mode.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials.
Incorrect access control in the preHandle function of my-site v1.0.2.RELEASE allows attackers to access sensitive components without authentication.
Bitcoin Core through 28.x has a security issue, the details of which are not disclosed. The earliest affected version is 0.14.
Incorrect access control in the preHandle function of SpringBootBlog v1.0.0 allows attackers to access sensitive components without authentication.
youlai-boot V2.21.1 is vulnerable to Incorrect Access Control. The getRoleForm function in SysRoleController.java does not perform permission checks, which may allow non-root users to directly access root roles.
A security vulnerability has been detected in D-Link DIR-823G 1.0.2B05. The affected element is the function GetDDNSSettings/GetDeviceDomainName/GetDeviceSettings/GetDMZSettings/GetFirewallSettings/GetGuestNetworkSettings/GetLanWanConflictInfo/GetLocalMacAddress/GetNetworkSettings/GetQoSSettings/GetRouterInformationSettings/GetRouterLanSettings/GetWanSettings/SetAccessCtlList/SetAccessCtlSwitch/SetDeviceSettings/SetGuestWLanSettings/SetIPv4FirewallSettings/SetNetworkSettings/SetNetworkTomographySettings/SetNTPServerSettings/SetRouterLanSettings/SetStaticClientInfo/SetStaticRouteSettings/SetWLanRadioSecurity/SetWPSSettings/UpdateClientInfo of the component goahead. Such manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
An Improper Access Control vulnerability in the Juniper Networks Paragon Active Assurance Control Center allows an unauthenticated attacker to leverage a crafted URL to generate PDF reports, potentially containing sensitive configuration information. A feature was introduced in version 3.1 of the Paragon Active Assurance Control Center which allows users to selective share account data using a unique identifier. Knowing the proper format of the URL and the identifier of an existing object in an application it is possible to get access to that object without being logged in, even if the object is not shared, resulting in the opportunity for malicious exfiltration of user data. Note that the Paragon Active Assurance Control Center SaaS offering is not affected by this issue. This issue affects Juniper Networks Paragon Active Assurance version 3.1.0.
Jenkins Compuware Topaz for Total Test Plugin 2.4.8 and earlier implements an agent/controller message that does not limit where it can be executed, allowing attackers able to control agent processes to read arbitrary files on the Jenkins controller file system.
An unauthorized user could be able to read any file on the system, potentially exposing sensitive information.
A vulnerability in the web-based management interface of Cisco Small Business RV320 and RV325 Dual Gigabit WAN VPN Routers could allow an unauthenticated, remote attacker to retrieve sensitive information. The vulnerability is due to improper access controls for URLs. An attacker could exploit this vulnerability by connecting to an affected device via HTTP or HTTPS and requesting specific URLs. A successful exploit could allow the attacker to download the router configuration or detailed diagnostic information. Cisco has released firmware updates that address this vulnerability.
In zulip before 1.3.12, deactivated users could access messages if SSO was enabled.
Incorrect access control in the /api/v1/conversations/*/files API of GT Edge AI Platform before v2.0.10 allows unauthorized attackers to access other users' uploaded files.
Database connections on deleted users could stay active on MySQL data sources in Remote Desktop Manager 2022.3.7 and below which allow deleted users to access unauthorized data. This issue affects : Remote Desktop Manager 2022.3.7 and prior versions.
Chartbrew is an open-source web application that can connect directly to databases and APIs and use the data to create charts. In version 4.9.0, Chartbrew exposes public chart retrieval and export routes that only verify project-level public access and, for exports, a team-level export toggle. The routes do not verify whether the target chart is actually allowed on the public report or whether the governing SharePolicy permits public access. An unauthenticated attacker who knows a chart identifier in a public project can read or export chart data for charts that were intentionally hidden from the report. This issue has been patched in version 5.0.0.
An access control issue exists in < 12.3.5, < 12.2.8, and < 12.1.14 for GitLab Community Edition (CE) and Enterprise Edition (EE) where private merge requests and issues would be disclosed with the Group Search feature provided by Elasticsearch integration
Improper access control vulnerability in GedSamsungAccount.kt SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via implicit broadcast.
Improper access control vulnerability in RegisteredEventMediator.kt SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via implicit broadcast.
Improper access control vulnerability in cloudNotificationManager.java SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via SHOW_PERSISTENT_BANNER broadcast.
Real-time image information exposure is caused by insufficient authentication for activated RTSP port. This vulnerability could allow to remote attackers to send the RTSP requests using ffplay command and lead to leakage a live image.
Improper access control vulnerability in cloudNotificationManager.java SmartThings prior to version 1.7.89.0 allows attackers to access sensitive information via REMOVE_PERSISTENT_BANNER broadcast.
The mobile application (com.transsion.videocallenhancer) interface has improper permission control, which can lead to the risk of private file leakage.
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
Vite is a frontend tooling framework for JavaScript. From 7.1.0 to before 7.3.2 and 8.0.5, on the Vite dev server, files that should be blocked by server.fs.deny (e.g., .env, *.crt) can be retrieved with HTTP 200 responses when query parameters such as ?raw, ?import&raw, or ?import&url&inline are appended. This vulnerability is fixed in 7.3.2 and 8.0.5.
An Incorrect Access Control vulnerability was found in /admin/rooms.php in Kashipara Hotel Management System v1.0, which allows an unauthenticated attacker to view valid hotel room entries in administrator section.
Improper access control in reporting engine of Odoo Community 14.0 through 15.0, and Odoo Enterprise 14.0 through 15.0, allows remote attackers to download PDF reports for arbitrary documents, via crafted requests.
Incorrect access control in the component orderService.queryObject of platform v1.0.0 allows attackers to access sensitive information via a crafted request.
A vulnerability, which was classified as problematic, was found in D-Link DI-7003GV2 24.04.18D1 R(68125). Affected is an unknown function of the file /index.data. The manipulation leads to information disclosure. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
An access control issue in the CheckVip function in UserController.java of IceCMS v3.4.7 and before allows unauthenticated attackers to access and returns all user information, including passwords
Vulnerability in the Java VM component of Oracle Database Server. Supported versions that are affected are 19.3-19.30 and 21.3-21.21. Easily exploitable vulnerability allows unauthenticated attacker with network access via Oracle Net to compromise Java VM. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Java VM accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
OpenSynergy BlueSDK (aka Blue SDK) through 6.x mishandles a function call. The specific flaw exists within the BlueSDK Bluetooth stack. The issue results from an incorrect variable used as a function argument. An attacker can leverage this to cause unexpected behavior or obtain sensitive information.
Zoho ManageEngine OpManager, OpManager Plus, OpManager MSP, Network Configuration Manager, NetFlow Analyzer, Firewall Analyzer, and OpUtils before 2022-07-27 through 2022-07-28 (125657, 126002, 126104, and 126118) allow unauthenticated attackers to obtain a user's API key, and then access external APIs.
An information disclosure vulnerability in the /Letter/PrintQr/ endpoint of Solvait v24.4.2 allows attackers to access sensitive data via a crafted request.
Distribution is a toolkit to pack, ship, store, and deliver container content. Prior to 3.1.0, distribution can restore read access in repo a after an explicit delete when storage.cache.blobdescriptor: redis and storage.delete.enabled: true are both enabled. The delete path clears the shared digest descriptor but leaves stale repo-scoped membership behind, so a later Stat or Get from repo b repopulates the shared descriptor and makes the deleted blob readable from repo a again. This vulnerability is fixed in 3.1.0.