Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-4554

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-22 Mar, 2026 | 16:51
Updated At-25 Mar, 2026 | 13:48
Rejected At-
Credits

Tenda F453 WriteFacMac FormWriteFacMac privilege escalation

A security flaw has been discovered in Tenda F453 1.0.0.3. The affected element is the function FormWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:22 Mar, 2026 | 16:51
Updated At:25 Mar, 2026 | 13:48
Rejected At:
â–¼CVE Numbering Authority (CNA)
Tenda F453 WriteFacMac FormWriteFacMac privilege escalation

A security flaw has been discovered in Tenda F453 1.0.0.3. The affected element is the function FormWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

Affected Products
Vendor
Tenda Technology Co., Ltd.Tenda
Product
F453
CPEs
  • cpe:2.3:o:tenda:f453_firmware:*:*:*:*:*:*:*:*
Versions
Affected
  • 1.0.0.3
Problem Types
TypeCWE IDDescription
CWECWE-77Command Injection
CWECWE-74Injection
Type: CWE
CWE ID: CWE-77
Description: Command Injection
Type: CWE
CWE ID: CWE-74
Description: Injection
Metrics
VersionBase scoreBase severityVector
4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
2.06.5N/A
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R
Version: 2.0
Base score: 6.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
LtzHust (VulDB User)
Timeline
EventDate
Advisory disclosed2026-03-21 00:00:00
VulDB entry created2026-03-21 01:00:00
VulDB entry last update2026-03-21 18:02:31
Event: Advisory disclosed
Date: 2026-03-21 00:00:00
Event: VulDB entry created
Date: 2026-03-21 01:00:00
Event: VulDB entry last update
Date: 2026-03-21 18:02:31
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.352381
vdb-entry
technical-description
https://vuldb.com/?ctiid.352381
signature
permissions-required
https://vuldb.com/?submit.774933
third-party-advisory
https://github.com/Litengzheng/vul_db/blob/main/F453/vul_95/README.md
exploit
https://www.tenda.com.cn/
product
Hyperlink: https://vuldb.com/?id.352381
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.352381
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/?submit.774933
Resource:
third-party-advisory
Hyperlink: https://github.com/Litengzheng/vul_db/blob/main/F453/vul_95/README.md
Resource:
exploit
Hyperlink: https://www.tenda.com.cn/
Resource:
product
â–¼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:22 Mar, 2026 | 17:17
Updated At:03 Apr, 2026 | 11:32

A security flaw has been discovered in Tenda F453 1.0.0.3. The affected element is the function FormWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.05.3MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Secondary
Version: 4.0
Base score: 5.3
Base severity: MEDIUM
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Tenda Technology Co., Ltd.
tenda
>>f453_firmware>>1.0.0.3
cpe:2.3:o:tenda:f453_firmware:1.0.0.3:*:*:*:*:*:*:*
Tenda Technology Co., Ltd.
tenda
>>f453>>-
cpe:2.3:h:tenda:f453:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-74Primarycna@vuldb.com
CWE-77Primarycna@vuldb.com
CWE-78Primarynvd@nist.gov
CWE ID: CWE-74
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-77
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/Litengzheng/vul_db/blob/main/F453/vul_95/README.mdcna@vuldb.com
Exploit
Third Party Advisory
https://vuldb.com/?ctiid.352381cna@vuldb.com
Permissions Required
VDB Entry
https://vuldb.com/?id.352381cna@vuldb.com
Third Party Advisory
VDB Entry
https://vuldb.com/?submit.774933cna@vuldb.com
Third Party Advisory
VDB Entry
https://www.tenda.com.cn/cna@vuldb.com
Product
Hyperlink: https://github.com/Litengzheng/vul_db/blob/main/F453/vul_95/README.md
Source: cna@vuldb.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://vuldb.com/?ctiid.352381
Source: cna@vuldb.com
Resource:
Permissions Required
VDB Entry
Hyperlink: https://vuldb.com/?id.352381
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://vuldb.com/?submit.774933
Source: cna@vuldb.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://www.tenda.com.cn/
Source: cna@vuldb.com
Resource:
Product

Change History

0
Information is not available yet

Similar CVEs

3726Records found

CVE-2024-10697
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-74.26% / 98.85%
||
7 Day CHG~0.00%
Published-02 Nov, 2024 | 12:00
Updated-05 Apr, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC6 API Endpoint WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6ac6_firmwareAC6ac6_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-5547
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.83% / 74.51%
||
7 Day CHG~0.00%
Published-05 Apr, 2026 | 07:15
Updated-07 Apr, 2026 | 13:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10 httpd formAddMacfilterRule os command injection

A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-AC10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-5339
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.14% / 34.76%
||
7 Day CHG~0.00%
Published-02 Apr, 2026 | 14:15
Updated-06 Apr, 2026 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G103 Setting gpon.lua action_set_net_settings command injection

A vulnerability was detected in Tenda G103 1.0.0.5. The impacted element is the function action_set_net_settings of the file gpon.lua of the component Setting Handler. Performing a manipulation of the argument authLoid/authLoidPassword/authPassword/authSerialNo/authType/oltType/usVlanId/usVlanPriority results in command injection. It is possible to initiate the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-g103g103_firmwareG103
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-5153
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.84% / 74.73%
||
7 Day CHG~0.00%
Published-30 Mar, 2026 | 21:30
Updated-02 Apr, 2026 | 12:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CH22 WriteFacMac FormWriteFacMac command injection

A flaw has been found in Tenda CH22 1.0.0.1. The affected element is the function FormWriteFacMac of the file /goform/WriteFacMac. Executing a manipulation of the argument mac can lead to command injection. The attack may be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ch22_firmwarech22CH22
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-15254
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.90% / 75.70%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 15:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6-S ATE Service ate TendaAte os command injection

A vulnerability was found in Tenda W6-S 1.0.0.4(510). This affects the function TendaAte of the file /goform/ate of the component ATE Service. Performing a manipulation results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6-s_firmwarew6-sW6-S
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-1819
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.74% / 72.87%
||
7 Day CHG~0.00%
Published-02 Mar, 2025 | 16:31
Updated-16 Jul, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 1200M telnet TendaTelnet os command injection

A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7 1200M
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-11523
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 60.29%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:02
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 AdvSetLanip command injection

A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11121
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 60.29%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 21:32
Updated-03 Oct, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 AdvSetLanip command injection

A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-45977
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-17.98% / 95.17%
||
7 Day CHG~0.00%
Published-12 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 V22.03.01.21_CN was found to have a command injection vulnerability via /goform/setMacFilterCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-9793
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-10.00% / 93.07%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 15:31
Updated-01 Nov, 2024 | 14:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_ifconfig_set command injection

A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-33530
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.00% / 76.97%
||
7 Day CHG~0.00%
Published-06 Jun, 2023 | 00:00
Updated-08 Jan, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in the Tenda G103 Gigabit GPON Terminal with firmware version V1.0.0.5. If an attacker gains web management privileges, they can inject commands gaining shell privileges.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g103g103_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2649
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-2.39% / 85.03%
||
7 Day CHG+1.14%
Published-11 May, 2023 | 08:00
Updated-02 Aug, 2024 | 06:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC23 Service Port 7329 ate command injection

A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac23_firmwareac23AC23
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-45043
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-17.98% / 95.17%
||
7 Day CHG~0.00%
Published-12 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 V22.03.01.16_cn is vulnerable to command injection via goform/fast_setting_internet_set.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12_firmwareax12n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-30023
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-29.91% / 96.66%
||
7 Day CHG~0.00%
Published-16 Jun, 2022 | 14:28
Updated-03 Aug, 2024 | 06:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-hg9_firmwarehg9n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-30425
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-18.93% / 95.33%
||
7 Day CHG~0.00%
Published-27 May, 2022 | 12:56
Updated-03 Aug, 2024 | 06:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-hg6_firmwarehg6n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-28572
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-17.52% / 95.09%
||
7 Day CHG~0.00%
Published-02 May, 2022 | 12:36
Updated-03 Aug, 2024 | 05:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX1806 v1.0.0.1 was discovered to contain a command injection vulnerability in `SetIPv6Status` function

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax1806ax1803_firmwareax1806_firmwareax1803n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-50853
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.08% / 89.81%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 00:00
Updated-21 Nov, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetDebugCfg function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g3_firmwaren/ag3
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2897
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-5.64% / 90.36%
||
7 Day CHG~0.00%
Published-26 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WriteFacMac formWriteFacMac os command injection

A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7ac7_firmwareAC7
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-25857
Matching Score-10
Assigner-VulnCheck
ShareView Details
Matching Score-10
Assigner-VulnCheck
CVSS Score-8.6||HIGH
EPSS-0.34% / 56.64%
||
7 Day CHG-0.05%
Published-07 Feb, 2026 | 21:41
Updated-05 Mar, 2026 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda G300-F Command Injection via formSetWanDiag

Tenda G300-F router firmware version 16.01.14.2 and prior contain an OS command injection vulnerability in the WAN diagnostic functionality (formSetWanDiag). The implementation constructs a shell command that invokes curl and incorporates attacker-controlled input into the command line without adequate neutralization. As a result, a remote attacker with access to the affected management interface can inject additional shell syntax and execute arbitrary commands on the device with the privileges of the management process.

Action-Not Available
Vendor-Shenzhen Tenda TechnologyTenda Technology Co., Ltd.
Product-g300-f_firmwareg300-fTenda G300-F
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10442
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.26%
||
7 Day CHG~0.00%
Published-15 Sep, 2025 | 11:02
Updated-19 Sep, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9/AC15 exeCommand formexeCommand os command injection

A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac9_firmwareac9ac15AC9AC15
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-1638
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 33.43%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 23:32
Updated-09 Mar, 2026 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC21 mDMZSetCfg command injection

A security flaw has been discovered in Tenda AC21 1.1.1.1/1.dmzip/16.03.08.16. The impacted element is the function mDMZSetCfg of the file /goform/mDMZSetCfg. The manipulation of the argument dmzIp results in command injection. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac21ac21_firmwareAC21
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-0581
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.15% / 78.53%
||
7 Day CHG~0.00%
Published-05 Jan, 2026 | 08:02
Updated-23 Feb, 2026 | 08:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 httpd BehaviorManager formBehaviorManager command injection

A vulnerability was determined in Tenda AC1206 15.03.06.23. Affected by this issue is the function formBehaviorManager of the file /goform/BehaviorManager of the component httpd. Executing a manipulation of the argument modulename/option/data/switch can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9090
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.72% / 85.96%
||
7 Day CHG~0.00%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7415
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.09% / 77.96%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 21:02
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd getTraceroute fromTraceroutGet command injection

A vulnerability, which was classified as critical, has been found in Tenda O3V2 1.0.0.12(3880). This issue affects the function fromTraceroutGet of the file /goform/getTraceroute of the component httpd. The manipulation of the argument dest leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7414
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.18% / 78.79%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5836
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.30% / 90.98%
||
7 Day CHG~0.00%
Published-07 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-46625
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.75% / 82.57%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Lack of input validation/sanitization in the 'setLanCfg' API endpoint in httpd in the Tenda RX2 Pro 16.03.30.14 allows a remote attacker that is authorized to the web management portal to gain root shell access to the device by sending a crafted web request. This is persistent because the command injection is saved in the configuration of the device.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-rx2_pro_firmwarerx2_pron/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44864
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.94%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the module parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44866
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.94%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the level parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5763
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-4.32% / 88.92%
||
7 Day CHG~0.00%
Published-06 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CP3 apollo sub_F3C8C command injection

A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-cp3cp3_firmwareCP3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5606
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-7.21% / 91.62%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 19:00
Updated-10 Jun, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-3908
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.34% / 88.95%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 11:31
Updated-17 Jan, 2025 | 21:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC500 WriteFacMac formWriteFacMac command injection

A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac500ac500_firmwareAC500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-3880
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.61% / 81.81%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 19:00
Updated-27 Jan, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W30E WriteFacMac formWriteFacMac os command injection

A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w30ew30e_firmwareW30Ew30e
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-44867
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.94%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetNetCheckTools function via the hostName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44865
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.94%
||
7 Day CHG~0.00%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the enable parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-32282
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.45% / 63.72%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-02 Aug, 2024 | 02:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1202_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-32281
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.29% / 87.23%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7ac7_firmwaren/aac7_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2991
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-6.10% / 90.80%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 18:31
Updated-22 Jan, 2025 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203FH1203fh1203_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-3009
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-5.91% / 90.61%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:31
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2854
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.53% / 81.35%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 05:31
Updated-12 Aug, 2024 | 18:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 setsambacfg formSetSambaConf os command injection

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18_firmwareac18AC18ac18_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2853
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.41% / 80.53%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 05:00
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2982
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.5||MEDIUM
EPSS-5.14% / 89.88%
||
7 Day CHG+2.25%
Published-27 Mar, 2024 | 15:31
Updated-14 Jan, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 WriteFacMac formWriteFacMac command injection

A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258151. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2851
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.41% / 80.53%
||
7 Day CHG~0.00%
Published-24 Mar, 2024 | 03:00
Updated-22 Aug, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15ac15_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-50852
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.08% / 89.81%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 00:00
Updated-21 Nov, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda G3 v3.0 v15.11.0.20 was discovered to contain a command injection vulnerability via the formSetUSBPartitionUmount function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-g3g3_firmwaren/ag3
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-2812
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.64% / 89.31%
||
7 Day CHG~0.00%
Published-22 Mar, 2024 | 06:31
Updated-01 Aug, 2024 | 19:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 WriteFacMac formWriteFacMac os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-2707
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.90% / 83.28%
||
7 Day CHG~0.00%
Published-20 Mar, 2024 | 17:00
Updated-12 Dec, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC10U WriteFacMac formWriteFacMac os command injection

A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10uac10u_firmwareAC10Uac10u_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-11745
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 34.93%
||
7 Day CHG+0.04%
Published-26 Nov, 2024 | 21:00
Updated-03 Dec, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8ac8_firmwareAC8ac8_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-15253
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 28.72%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 15:02
Updated-24 Feb, 2026 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda M3 exeCommand stack-based overflow

A vulnerability has been found in Tenda M3 1.0.0.13(4903). The impacted element is an unknown function of the file /goform/exeCommand. Such manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-m3_firmwarem3M3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-5988
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.80%
||
7 Day CHG~0.00%
Published-09 Apr, 2026 | 23:00
Updated-14 Apr, 2026 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F451 AdvSetWrlsafeset formWrlsafeset stack-based overflow

A vulnerability was detected in Tenda F451 1.0.0.7. This impacts the function formWrlsafeset of the file /goform/AdvSetWrlsafeset. Performing a manipulation of the argument mit_ssid results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-F451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-4298
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.93% / 76.17%
||
7 Day CHG~0.00%
Published-05 May, 2025 | 23:31
Updated-13 May, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 setcfm formSetCfm buffer overflow

A vulnerability was found in Tenda AC1206 up to 15.03.06.23. It has been declared as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm. The manipulation leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206ac1206_firmwareAC1206
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 74
  • 75
  • Next
Details not found