A vulnerability has been found in Tenda AC20 16.03.08.12. This affects the function set_qosMib_list of the file /goform/SetNetControlList of the component SetNetControlList Endpoint. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. This vulnerability affects the function formWlanSetupWPS of the file /goform/formWlanSetupWPS of the component webs. The manipulation of the argument wps_enrolee_pin/webpage leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda A15 15.13.07.09/15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/multimodalAdd of the component HTTP POST Request Handler. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A flaw has been found in UTT HiPER 1250GW up to 3.2.7-210907-180535. Affected by this issue is the function strcpy of the file /goform/formGroupConfig of the component Web Management Interface. Executing a manipulation of the argument Profile can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
A vulnerability classified as critical was found in Tenda AC20 16.03.08.05. Affected by this vulnerability is the function strcpy of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DI-8100 1.0. It has been declared as critical. Affected by this vulnerability is the function sprintf of the file /ddns.asp?opt=add of the component jhttpd. The manipulation of the argument mx leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A flaw was found in samba versions 4.0.0 to 4.5.2. The Samba routine ndr_pull_dnsp_name contains an integer wrap problem, leading to an attacker-controlled memory overwrite. ndr_pull_dnsp_name parses data from the Samba Active Directory ldb database. Any user who can write to the dnsRecord attribute over LDAP can trigger this memory corruption. By default, all authenticated LDAP users can write to the dnsRecord attribute on new DNS objects. This makes the defect a remote privilege escalation.
Advantech EKI-1524, EKI-1522, EKI-1521 devices through 1.21 are affected by a Stack-based Buffer Overflow vulnerability, which can be triggered by authenticated users via a crafted POST request.
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/UserCongratulationsExec. The manipulation of the argument getuid leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in D-Link DIR-619L 2.06B01. This affects the function formAutoDetecWAN_wizard4 of the file /goform/formAutoDetecWAN_wizard4. The manipulation of the argument curTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability has been found in TOTOLINK A702R 4.0.0-B20230721.1521 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formIpv6Setup of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. Affected by this issue is some unknown functionality of the file /boafrm/formSysCmd of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been rated as critical. This issue affects the function sub_484E40 of the file /goform/formP2PLimitConfig of the component API. The manipulation of the argument except leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. This vulnerability affects unknown code of the file /boafrm/formDMZ of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. This affects the function SubUPnPCSInit of the file /sbin/udev. The manipulation of the argument CameraName leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. It has been classified as critical. Affected is an unknown function of the file /boafrm/formSetLg of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. It has been rated as critical. Affected by this issue is the function submit-url of the file /boafrm/formReflashClientTbl of the component HTTP POST Request Handler. The manipulation leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TOTOLINK A3002R 1.1.1-B20200824.0128. It has been rated as critical. This issue affects the function formRoute of the file /boafrm/formRoute. The manipulation of the argument subnet leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. This affects an unknown part of the file /boafrm/formWsc of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, was found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. This affects an unknown part of the file /boafrm/formSiteSurveyProfile of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DCS-932L 2.18.01 and classified as critical. Affected by this issue is the function sub_404780 of the file /bin/gpio. The manipulation of the argument CameraName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability classified as critical was found in TOTOLINK A702R, A3002R and A3002RU 3.0.0-B20230809.1615. Affected by this vulnerability is the function sub_40BE30 of the file /boafrm/formStats of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical was found in D-Link DIR-619L 2.06B01. Affected by this vulnerability is the function formWlanGuestSetup of the file /goform/formWlanGuestSetup. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in TOTOLINK A3002R and A3002RU 3.0.0-B20230809.1615/4.0.0-B20230531.1404. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /boafrm/formTmultiAP of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in H3C GR-3000AX V100R007L50. It has been classified as critical. Affected is the function UpdateWanParamsMulti/UpdateIpv6Params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation.
A vulnerability, which was classified as critical, has been found in TOTOLINK EX1200T up to 4.1.2cu.5232_B20210713. This issue affects some unknown processing of the file /boafrm/formIpQoS of the component HTTP POST Request Handler. The manipulation leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in TOTOLINK EX1200T up to 4.1.2cu.5232_B20210713 and classified as critical. Affected by this issue is some unknown functionality of the file /boafrm/formDMZ of the component HTTP POST Request Handler. The manipulation leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
APTIOV contains a vulnerability in the BIOS where a user or attacker may cause an improper restriction of operations within the bounds of a memory buffer over the network. A successful exploitation of this vulnerability may lead to code execution outside of the intended System Management Mode.