IBM Sterling Connect:Direct for UNIX command execution
IBM Sterling Connect Direct for Unix 6.2.0.7 through 6.2.0.9 iFix004, 6.4.0.0 through 6.4.0.2 iFix001, and 6.3.0.2 through 6.3.0.5 iFix002 incorrectly assigns permissions for maintenance tasks to Control Center Director (CCD) users that could allow a privileged user to escalate their privileges further due to unnecessary privilege assignment for post update scripts.
Description: CWE-250 Execution with Unnecessary Privileges
Metrics
Version
Base score
Base severity
Vector
3.1
7.2
HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Version:3.1
Base score:7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC ID
Description
Solutions
Remediation/Fixes IBM strongly recommends addressing the vulnerability now by upgrading Product Version Remediation/Fix/Instructions IBM Sterling Connect:Direct for UNIX 6.4.0 Apply 6.4.0.2.iFix004, available on Fix Central . IBM Sterling Connect:Direct for UNIX 6.3.0 Apply 6.3.0.5.iFix008, available on Fix Central . IBM Sterling Connect:Direct for UNIX 6.2.0 Apply 6.2.0.9.iFix005, available on Fix Central .