A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition
Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors.
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing BMP files. This can result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12018)
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182)
Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.
A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing TIFF files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12158)
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
Buffer overflow in the WebClient ActiveX control in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 3), Solid Edge SE2023 (All versions < V223.0 Update 2). Affected applications contain a memory corruption vulnerability while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19561)
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). When processing a DHCP ACK message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0013)
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code.
Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.
LGSERVER.EXE in BrightStor ARCserve Backup for Laptops & Desktops r11.1 allows remote attackers to cause a denial of service (daemon crash) via a value of 0xFFFFFFFF at a certain point in an authentication negotiation packet, which results in an out-of-bounds read.
The Clientless SSL VPN feature in Cisco Adaptive Security Appliance (ASA) Software 8.x before 8.2(5.44), 8.3.x before 8.3(2.39), 8.4.x before 8.4(5.7), 8.6.x before 8.6(1.12), 9.0.x before 9.0(2.6), and 9.1.x before 9.1(1.7) allows remote attackers to cause a denial of service (device reload) via crafted HTTPS requests, aka Bug ID CSCua22709.
A vulnerability in the cache server within Cisco Videoscape Distribution Suite (VDS) for Television 3.2(5)ES1 could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on a targeted appliance. The vulnerability is due to excessive mapped connections exhausting the allotted resources within the system. An attacker could exploit this vulnerability by sending large amounts of inbound traffic to a device with the intention of overloading certain resources. A successful exploit could cause the device to reload, resulting in a DoS condition. Cisco Bug IDs: CSCvc39260.
All versions of Quagga, 0.93 through 1.1.0, are vulnerable to an unbounded memory allocation in the telnet 'vty' CLI, leading to a Denial-of-Service of Quagga daemons, or even the entire host. When Quagga daemons are configured with their telnet CLI enabled, anyone who can connect to the TCP ports can trigger this vulnerability, prior to authentication. Most distributions restrict the Quagga telnet interface to local access only by default. The Quagga telnet interface 'vty' input buffer grows automatically, without bound, so long as a newline is not entered. This allows an attacker to cause the Quagga daemon to allocate unbounded memory by sending very long strings without a newline. Eventually the daemon is terminated by the system, or the system itself runs out of memory. This is fixed in Quagga 1.1.1 and Free Range Routing (FRR) Protocol Suite 2017-01-10.
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCut50727.
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCuu76493.
Multiple vulnerabilities in the EnergyWise module of Cisco IOS (12.2 and 15.0 through 15.6) and Cisco IOS XE (3.2 through 3.18) could allow an unauthenticated, remote attacker to cause a buffer overflow condition or a reload of an affected device, leading to a denial of service (DoS) condition. These vulnerabilities are due to improper parsing of crafted EnergyWise packets destined to an affected device. An attacker could exploit these vulnerabilities by sending crafted EnergyWise packets to be processed by an affected device. An exploit could allow the attacker to cause a buffer overflow condition or a reload of the affected device, leading to a DoS condition. Cisco IOS Software and Cisco IOS XE Software support EnergyWise for IPv4 communication. Only IPv4 packets destined to a device configured as an EnergyWise domain member can trigger these vulnerabilities. IPv6 packets cannot be used to trigger these vulnerabilities. Cisco Bug ID CSCur29331.
A vulnerability in the Session Initiation Protocol (SIP) UDP throttling process of Cisco Unified Communications Manager (Cisco Unified CM) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient rate limiting protection. An attacker could exploit this vulnerability by sending the affected device a high rate of SIP messages. An exploit could allow the attacker to cause the device to reload unexpectedly. The device and services will restart automatically. This vulnerability affects Cisco Unified Communications Manager (CallManager) releases prior to the first fixed release; the following list indicates the first minor release that includes the fix for this vulnerability: 10.5.2.14900-16 11.0.1.23900-5 11.5.1.12900-2. Cisco Bug IDs: CSCuz72455.
Huawei AR 150, 200, 1200, 2200, and 3200 routers, when SNMPv3 is enabled, allow remote attackers to cause a denial of service (device crash) via malformed SNMPv3 requests that leverage unspecified overflow issues.
Panda Global Protection 17.0.1 allows a system crash via a 0xb3702c44 \\.\PSMEMDriver DeviceIoControl request.
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
The TCP/IP implementation in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8, Windows Server 2012, and Windows RT does not properly perform memory allocation for inbound ICMPv6 packets, which allows remote attackers to cause a denial of service (system hang) via crafted packets, aka "ICMPv6 Vulnerability."
Stack-based buffer overflow in the bpe_decompress function in (1) BlackBerry QNX Neutrino RTOS through 6.5.0 SP1 and (2) QNX Momentics Tool Suite through 6.5.0 SP1 in the QNX Software Development Platform allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via crafted packets to TCP port 4868.
Cisco Intrusion Prevention System (IPS) Software on IPS NME devices before 7.0(9)E4 allows remote attackers to cause a denial of service (device reload) via malformed IPv4 packets that trigger incorrect memory allocation, aka Bug ID CSCua61977.
libdns in ISC BIND 9.7.x and 9.8.x before 9.8.4-P2, 9.8.5 before 9.8.5b2, 9.9.x before 9.9.2-P2, and 9.9.3 before 9.9.3b2 on UNIX platforms allows remote attackers to cause a denial of service (memory consumption) via a crafted regular expression, as demonstrated by a memory-exhaustion attack against a machine running a named process.
A vulnerability in SSL/TLS message handler for Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. This vulnerability exists because incoming SSL/TLS packets are not properly processed. An attacker could exploit this vulnerability by sending a crafted SSL/TLS packet to an affected device. A successful exploit could allow the attacker to cause the affected device to reload, resulting in a DoS condition.
The Smart Install client functionality in Cisco IOS 12.2 and 15.0 through 15.3 on Catalyst switches allows remote attackers to cause a denial of service (device reload) via crafted image list parameters in Smart Install packets, aka Bug ID CSCub55790.
Buffer overflow in Microsoft SharePoint Server 2010 SP1 and SharePoint Foundation 2010 SP1 allows remote attackers to cause a denial of service (W3WP process crash and site outage) via a crafted URL, aka "Buffer Overflow Vulnerability."
VMware vCenter Server 4.1 before Update 3 and 5.0 before Update 2, and vCSA 5.0 before Update 2, allows remote attackers to cause a denial of service (disk consumption) via vectors that trigger large log entries.
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
On the Vonage VDV-23 115 3.2.11-0.9.40 home router, sending a long string of characters in the loginPassword and/or loginUsername field to goform/login causes the router to reboot.