Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:21 Mar, 2013 | 15:00
Updated At:16 Sep, 2024 | 19:47
Rejected At:
▼CVE Numbering Authority (CNA)

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
x_refsource_CONFIRM
http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
x_refsource_MISC
Hyperlink: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
Resource:
x_refsource_CONFIRM
Hyperlink: http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
x_refsource_CONFIRM
x_transferred
http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
x_refsource_MISC
x_transferred
Hyperlink: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:21 Mar, 2013 | 15:55
Updated At:11 Apr, 2025 | 00:51

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>simatic_pcs7>>Versions up to 8.0(inclusive)
cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>simatic_pcs7>>7.1
cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>Versions up to 7.1(inclusive)
cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>5.0
cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>5.0
cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>6.0
cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>6.0
cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>6.0
cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>6.0
cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>7.0
cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>7.0
cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>7.0
cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*
Siemens AG
siemens
>>wincc>>7.0
cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarynvd@nist.gov
CWE ID: CWE-119
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfics-cert@hq.dhs.gov
US Government Resource
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdfics-cert@hq.dhs.gov
Vendor Advisory
http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdfaf854a3a-2127-422b-91ae-364da2661108
US Government Resource
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdfaf854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
Source: ics-cert@hq.dhs.gov
Resource:
US Government Resource
Hyperlink: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
Source: ics-cert@hq.dhs.gov
Resource:
Vendor Advisory
Hyperlink: http://ics-cert.us-cert.gov/pdf/ICSA-13-079-02.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
US Government Resource
Hyperlink: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-714398.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

2230Records found

CVE-2013-0656
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-2.13% / 83.48%
||
7 Day CHG~0.00%
Published-21 Jan, 2013 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_rf-manager_2008simatic_rf-managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-46153
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 62.90%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44018
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.31% / 53.35%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15112)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationSolid Edge SE2021Teamcenter Visualization V13.2Teamcenter Visualization V13.3JT2GoTeamcenter Visualization V13.1Solid Edge SE2022
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-34306
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13342)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27397
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.67%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22649
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.72%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:02
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-26997
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 62.83%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2020Solid Edge SE2021Solid Edge SE2020
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-24661
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-03 Aug, 2024 | 04:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_star-ccm\+_viewerSimcenter STAR-CCM+ Viewer
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-46157
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.67%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14757)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44016
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.31% / 53.35%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2.0.7), Solid Edge SE2021 (All versions < SE2021MP9), Solid Edge SE2022 (All versions < SE2022MP1), Teamcenter Visualization V13.1 (All versions < V13.1.0.9), Teamcenter Visualization V13.2 (All versions < V13.2.0.7), Teamcenter Visualization V13.3 (All versions < V13.3.0.1). The plmxmlAdapterSE70.dll library is vulnerable to memory corruption condition while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15110)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationSolid Edge SE2021Teamcenter Visualization V13.2Teamcenter Visualization V13.3JT2GoTeamcenter Visualization V13.1Solid Edge SE2022
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44440
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.37% / 57.90%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to memory corruption condition while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14912)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-29878
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.44% / 62.28%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a valid challenge-response pair generated by a legitimate user, and request the webpage repeatedly to wait for the same challenge to reappear for which the correct response is known. This could allow the attacker to access the management interface of the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg8501-0aa11-2aa0_firmware7kg8551-0aa01-2aa07kg8501-0aa11-0aa07kg8500-0aa10-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8551-0aa02-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-0aa07kg8550-0aa00-0aa0_firmware7kg8501-0aa01-0aa07kg8551-0aa02-0aa07kg8500-0aa30-0aa07kg8551-0aa32-0aa0_firmware7kg8551-0aa02-2aa07kg8550-0aa30-0aa0_firmware7kg8501-0aa32-0aa07kg8500-0aa30-2aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa12-2aa07kg8500-0aa00-0aa07kg8551-0aa01-0aa0_firmware7kg8501-0aa11-2aa07kg8501-0aa31-0aa07kg8501-0aa12-2aa0_firmware7kg8501-0aa32-2aa07kg8550-0aa00-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa31-0aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa12-0aa0_firmware7kg8551-0aa12-0aa07kg8500-0aa30-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8500-0aa00-2aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8501-0aa02-0aa0_firmware7kg8500-0aa10-0aa07kg8551-0aa12-0aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa32-2aa07kg8501-0aa11-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa02-2aa0_firmware7kg8551-0aa32-0aa07kg8501-0aa32-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8501-0aa01-2aa07kg8550-0aa00-2aa07kg8551-0aa31-2aa0_firmware7kg8551-0aa11-2aa07kg8501-0aa12-0aa07kg8551-0aa31-0aa0_firmware7kg8551-0aa11-0aa07kg8500-0aa00-2aa07kg8551-0aa01-2aa0_firmware7kg8550-0aa10-2aa0_firmware7kg8550-0aa10-0aa07kg8551-0aa31-0aa07kg8551-0aa11-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8551-0aa01-0aa07kg8501-0aa02-2aa07kg8500-0aa10-2aa07kg8551-0aa31-2aa07kg8501-0aa31-2aa07kg8501-0aa12-2aa07kg8500-0aa00-0aa0_firmwareSICAM P850SICAM P855
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-28661
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.65%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:08
Updated-03 Aug, 2024 | 06:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-29032
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.54% / 66.63%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization V13.3Teamcenter Visualization V14.0
CWE ID-CWE-415
Double Free
CVE-2022-25754
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.23% / 46.08%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2022-22826
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.21% / 42.84%
||
7 Day CHG~0.00%
Published-08 Jan, 2022 | 02:56
Updated-05 May, 2025 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

Action-Not Available
Vendor-libexpat_projectn/aSiemens AGTenable, Inc.Debian GNU/Linux
Product-nessussinema_remote_connect_serverdebian_linuxlibexpatn/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-22825
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.21% / 42.84%
||
7 Day CHG~0.00%
Published-08 Jan, 2022 | 02:56
Updated-05 May, 2025 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

lookup in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.

Action-Not Available
Vendor-libexpat_projectn/aSiemens AGTenable, Inc.Debian GNU/Linux
Product-nessussinema_remote_connect_serverdebian_linuxlibexpatn/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2020-10039
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.20% / 42.30%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2019-6584
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.08%
||
7 Day CHG~0.00%
Published-12 Jun, 2019 | 13:47
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-logo\!8_firmwarelogo\!8SIEMENS LOGO!8
CWE ID-CWE-384
Session Fixation
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2021-44443
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:07
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitJTTKJT Utilities
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-19289
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.17% / 38.32%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-xhqXHQ
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2020-12762
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.67%
||
7 Day CHG-0.01%
Published-09 May, 2020 | 00:00
Updated-30 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend.

Action-Not Available
Vendor-json-cn/aDebian GNU/LinuxFedora ProjectSiemens AGCanonical Ltd.
Product-fedoradebian_linuxubuntu_linuxsinec_insjson-cn/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-10939
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.48%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 19:50
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.

Action-Not Available
Vendor-Siemens AG
Product-tim_4r-ie_dnp3tim_4r-ietim_4r-ie_firmwaretim_3v-ie_dnp3_firmwaretim_3v-ie_advancedtim_3v-ie_advanced_firmwaretim_3v-ie_firmwaretim_3v-ietim_3v-ie_dnp3tim_4r-ie_dnp3_firmwareTIM 3V-IE DNP3 (incl. SIPLUS NET variants)TIM 4R-IE (incl. SIPLUS NET variants)TIM 4R-IE DNP3 (incl. SIPLUS NET variants)TIM 3V-IE (incl. SIPLUS NET variants)TIM 3V-IE Advanced (incl. SIPLUS NET variants)
CWE ID-CWE-489
Active Debug Code
CVE-2021-32948
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.16% / 37.53%
||
7 Day CHG~0.00%
Published-17 Jun, 2021 | 00:00
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_sdkteamcenter_visualizationDrawings SDK
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34291
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12956)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2020-10045
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.33% / 55.35%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2018-7891
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.1||HIGH
EPSS-3.78% / 87.60%
||
7 Day CHG~0.00%
Published-30 Apr, 2018 | 15:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Milestone XProtect Video Management Software (Corporate, Expert, Professional+, Express+, Essential+) 2016 R1 (10.0.a) to 2018 R1 (12.1a) contains .NET Remoting endpoints that are vulnerable to deserialization attacks resulting in remote code execution.

Action-Not Available
Vendor-milestonesysn/aSiemens AG
Product-siveillance_vmsxprotectn/a
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2015-1597
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.40% / 60.03%
||
7 Day CHG~0.00%
Published-07 Mar, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.

Action-Not Available
Vendor-n/aSiemens AG
Product-spcanywheren/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2015-1601
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.40% / 59.58%
||
7 Day CHG~0.00%
Published-06 Apr, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_step_7n/a
CVE-2018-13814
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.64%
||
7 Day CHG~0.00%
Published-13 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 09:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp700fsimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_tpsimatic_hmi_ktp_mobile_panels_ktp900fsimatic_hmi_tp_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsimatic_hmi_comfort_outdoor_panelssimatic_hmi_comfort_outdoor_panels_firmwaresimatic_wincc_\(tia_portal\)simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresimatic_wincc_runtimesimatic_hmi_op_firmwaresimatic_hmi_mp_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_opsimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_panelssimatic_hmi_comfort_panels_firmwaresimatic_hmi_mpsimatic_hmi_ktp_mobile_panels_ktp700_firmwareSIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)
CWE ID-CWE-113
Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting')
CWE ID-CWE-20
Improper Input Validation
CVE-2018-11455
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-2.66% / 85.18%
||
7 Day CHG~0.00%
Published-07 Aug, 2018 | 15:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.

Action-Not Available
Vendor-Siemens AG
Product-automation_license_managerAutomation License Manager 5, Automation License Manager 6
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-11447
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.17% / 38.29%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-17 Sep, 2024 | 02:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-scalance_m875scalance_m875_firmwareSCALANCE M875
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-27396
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.94% / 75.23%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-27494
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.62% / 69.04%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 15:26
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-luxiondatakitn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-27381
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-25678
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.67%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2020Solid Edge SE2021Solid Edge SE2020
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-46699
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.88% / 74.42%
||
7 Day CHG~0.00%
Published-22 Feb, 2022 | 17:52
Updated-04 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains a stack based buffer overflow vulnerability while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15061)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-46160
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15286)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2013-4911
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.29% / 51.42%
||
7 Day CHG~0.00%
Published-31 Jul, 2013 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccn/a
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-46158
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-1.24% / 78.43%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-1284
Improper Validation of Specified Quantity in Input
CVE-2014-4686
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.23% / 45.84%
||
7 Day CHG~0.00%
Published-24 Jul, 2014 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_pcs7winccn/a
CVE-2021-46156
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14684)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-2682
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.21% / 43.09%
||
7 Day CHG~0.00%
Published-27 Feb, 2017 | 11:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_network_management_softwareRUGGEDCOM NMS All versions < V2.1 (Windows and Linux)
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-46152
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 62.90%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a type confusion vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14643, ZDI-CAN-14644, ZDI-CAN-14755, ZDI-CAN-15183)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-843
Access of Resource Using Incompatible Type ('Type Confusion')
CVE-2022-34465
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-34280
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-045)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-34276
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-041)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-46155
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-1.36% / 79.40%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14683, ZDI-CAN-15283, ZDI-CAN-15303, ZDI-CAN-15593)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap V2020.2Simcenter Femap V2021.1
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34275
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-040)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2012-3028
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-0.17% / 38.62%
||
7 Day CHG~0.00%
Published-18 Sep, 2012 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)