RSA BSAFE Crypto-C Micro Edition versions prior to 4.1.4 and RSA Micro Edition Suite versions prior to 4.4 are vulnerable to an Information Exposure Through Timing Discrepancy. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure.
Inappropriate implementation in BoringSSL SPAKE2 in Google Chrome prior to 63.0.3239.84 allowed a remote attacker to leak the low-order bits of SHA512(password) by inspecting protocol traffic.
An insecure communication was found between a user and the Orpak SiteOmat management console for all known versions, due to an invalid SSL certificate. The attack allows for an eavesdropper to capture the communication and decrypt the data.
IBM Security Guardium 10 and 10.5 uses a one-way cryptographic hash against an input that should not be reversible, such as a password, but the software does not also use a salt as part of the input. IBM X-Force ID: 124743.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
IBM Tivoli Application Dependency Discovery Manager (TADDM) before 7.2.1.5 and 7.2.x before 7.2.2 make it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging support for weak SSL ciphers. IBM X-Force ID: 84353.
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.