Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2016-10108

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-03 Jan, 2017 | 00:00
Updated At-06 Aug, 2024 | 03:07
Rejected At-
Credits

Unauthenticated Remote Command injection as root occurs in the Western Digital MyCloud NAS 2.11.142 /web/google_analytics.php URL via a modified arg parameter in the POST data.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:03 Jan, 2017 | 00:00
Updated At:06 Aug, 2024 | 03:07
Rejected At:
▼CVE Numbering Authority (CNA)

Unauthenticated Remote Command injection as root occurs in the Western Digital MyCloud NAS 2.11.142 /web/google_analytics.php URL via a modified arg parameter in the POST data.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
N/A
http://www.securityfocus.com/bid/95200
vdb-entry
http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
N/A
Hyperlink: https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
Resource: N/A
Hyperlink: http://www.securityfocus.com/bid/95200
Resource:
vdb-entry
Hyperlink: http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
x_transferred
http://www.securityfocus.com/bid/95200
vdb-entry
x_transferred
http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
x_transferred
Hyperlink: https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
Resource:
x_transferred
Hyperlink: http://www.securityfocus.com/bid/95200
Resource:
vdb-entry
x_transferred
Hyperlink: http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
Resource:
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:03 Jan, 2017 | 06:59
Updated At:12 Apr, 2025 | 10:46

Unauthenticated Remote Command injection as root occurs in the Western Digital MyCloud NAS 2.11.142 /web/google_analytics.php URL via a modified arg parameter in the POST data.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.09.8CRITICAL
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.010.0HIGH
AV:N/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 3.0
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 10.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Western Digital Corp.
western_digital
>>mycloud_nas>>2.11.142
cpe:2.3:a:western_digital:mycloud_nas:2.11.142:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

Organization : Western Digital
Last Modified : 2017-01-09T12:14:57.650

This was resolved via My Cloud product firmware update 2.11.157 for the My Cloud EX2, EX4, and Mirror (Gen 1) models, and My Cloud product firmware update 2.21.126 for all other affected My Cloud models (My Cloud, PR 4100, PR2100, DL4100, DL2100, EX4100, EX2100, EX2 Ultra models). The firmware updates were made available December 20, 2016. The product firmware updates are available through the Update Firmware option on the My Cloud device itself or from the specific My Cloud product model’s support page at: http://support.wdc.com/downloads.aspx?g=904&lang=en#downloads .

References
HyperlinkSourceResource
http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.htmlcve@mitre.org
N/A
http://www.securityfocus.com/bid/95200cve@mitre.org
N/A
https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/cve@mitre.org
Exploit
Third Party Advisory
http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.htmlaf854a3a-2127-422b-91ae-364da2661108
N/A
http://www.securityfocus.com/bid/95200af854a3a-2127-422b-91ae-364da2661108
N/A
https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/af854a3a-2127-422b-91ae-364da2661108
Exploit
Third Party Advisory
Hyperlink: http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
Source: cve@mitre.org
Resource: N/A
Hyperlink: http://www.securityfocus.com/bid/95200
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: http://packetstormsecurity.com/files/173802/Western-Digital-MyCloud-Unauthenticated-Command-Injection.html
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: http://www.securityfocus.com/bid/95200
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: https://www.stevencampbell.info/2016/12/command-injection-in-western-digital-mycloud-nas/
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

181Records found

CVE-2016-10107
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.34% / 88.67%
||
7 Day CHG~0.00%
Published-03 Jan, 2017 | 06:34
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unauthenticated Remote Command injection as root occurs in the Western Digital MyCloud NAS 2.11.142 index.php page via a modified Cookie header.

Action-Not Available
Vendor-n/aWestern Digital Corp.
Product-mycloud_nasn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-9951
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.31% / 79.46%
||
7 Day CHG~0.00%
Published-24 Apr, 2019 | 17:26
Updated-04 Aug, 2024 | 22:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Western Digital My Cloud, My Cloud Mirror Gen2, My Cloud EX2 Ultra, My Cloud EX2100, My Cloud EX4100, My Cloud DL2100, My Cloud DL4100, My Cloud PR2100 and My Cloud PR4100 firmware before 2.31.174 is affected by an unauthenticated file upload vulnerability. The page web/jquery/uploader/uploadify.php can be accessed without any credentials, and allows uploading arbitrary files to any location on the attached storage.

Action-Not Available
Vendor-n/aWestern Digital Corp.
Product-my_cloud_firmwaremy_cloud_dl2100my_cloud_pr4100my_cloud_mirror_gen_2_firmwaremy_cloudmy_cloud_ex4100my_cloud_ex2_ultramy_cloud_pr2100my_cloud_mirror_gen_2my_cloud_ex2100my_cloud_dl4100my_cloud_ex2100_firmwaremy_cloud_dl4100_firmwaremy_cloud_pr2100_firmwaremy_cloud_ex2_ultra_firmwaren/a
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-17153
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-92.20% / 99.70%
||
7 Day CHG~0.00%
Published-18 Sep, 2018 | 00:00
Updated-05 Aug, 2024 | 10:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

It was discovered that the Western Digital My Cloud device before 2.30.196 is affected by an authentication bypass vulnerability. An unauthenticated attacker can exploit this vulnerability to authenticate as an admin user without needing to provide a password, thereby gaining full control of the device. (Whenever an admin logs into My Cloud, a server-side session is created that is bound to the user's IP address. After the session is created, it is possible to call authenticated CGI modules by sending the cookie username=admin in the HTTP request. The invoked CGI will check if a valid session is present and bound to the user's IP address.) It was found that it is possible for an unauthenticated attacker to create a valid session without a login. The network_mgr.cgi CGI module contains a command called "cgi_get_ipv6" that starts an admin session -- tied to the IP address of the user making the request -- if the additional parameter "flag" with the value "1" is provided. Subsequent invocation of commands that would normally require admin privileges now succeed if an attacker sets the username=admin cookie.

Action-Not Available
Vendor-n/aWestern Digital Corp.
Product-my_cloud_mirror_gen_2_firmwaremy_cloud_wdbctl0020hwtmy_cloud_ex4my_cloud_ex2my_cloud_pr4100my_cloud_mirror_firmwaremy_cloud_ex4_firmwaremy_cloud_dl2100my_cloud_pr2100my_cloud_ex4100my_cloud_ex2_ultramy_cloud_mirror_gen_2my_cloud_mirrormy_cloud_ex2100my_cloud_dl4100my_cloud_wdbctl0020hwt_firmwaremy_cloud_ex2100_firmwaremy_cloud_dl4100_firmwaremy_cloud_pr2100_firmwaremy_cloud_ex2_firmwaremy_cloud_ex2_ultra_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2024-4078
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-9.8||CRITICAL
EPSS-9.76% / 92.78%
||
7 Day CHG~0.00%
Published-16 May, 2024 | 09:03
Updated-08 Aug, 2024 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary Code Execution in parisneo/lollms

A vulnerability in the parisneo/lollms, specifically in the `/unInstall_binding` endpoint, allows for arbitrary code execution due to insufficient sanitization of user input. The issue arises from the lack of path sanitization when handling the `name` parameter in the `unInstall_binding` function, allowing an attacker to traverse directories and execute arbitrary code by loading a malicious `__init__.py` file. This vulnerability affects the latest version of the software. The exploitation of this vulnerability could lead to remote code execution on the system where parisneo/lollms is deployed.

Action-Not Available
Vendor-ParisNeo (LoLLMs)
Product-parisneo/lollmslollms-webui
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-18377
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.17% / 86.65%
||
7 Day CHG~0.00%
Published-11 Jun, 2019 | 20:44
Updated-05 Aug, 2024 | 21:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Wireless IP Camera (P2P) WIFICAM cameras. There is Command Injection in the set_ftp.cgi script via shell metacharacters in the pwd variable, as demonstrated by a set_ftp.cgi?svr=192.168.1.1&port=21&user=ftp URI.

Action-Not Available
Vendor-goaheadn/a
Product-wireless_ip_camera_wificam_firmwarewireless_ip_camera_wificamn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-18378
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-15.54% / 94.52%
||
7 Day CHG~0.00%
Published-11 Jun, 2019 | 20:44
Updated-05 Aug, 2024 | 21:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In NETGEAR ReadyNAS Surveillance before 1.4.3-17 x86 and before 1.1.4-7 ARM, $_GET['uploaddir'] is not escaped and is passed to system() through $tmp_upload_dir, leading to upgrade_handle.php?cmd=writeuploaddir remote command execution.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-readynas_surveillancereadynas_surveillance_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-8255
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-5.20% / 89.69%
||
7 Day CHG~0.00%
Published-19 Dec, 2019 | 19:38
Updated-04 Aug, 2024 | 21:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Brackets versions 1.14 and earlier have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution.

Action-Not Available
Vendor-Linux Kernel Organization, IncAdobe Inc.Apple Inc.Microsoft Corporation
Product-windowsbracketslinux_kernelmac_os_xBrackets
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-7839
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-46.37% / 97.57%
||
7 Day CHG~0.00%
Published-12 Jun, 2019 | 15:14
Updated-04 Aug, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ColdFusion versions Update 3 and earlier, Update 10 and earlier, and Update 18 and earlier have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution.

Action-Not Available
Vendor-Adobe Inc.
Product-coldfusionColdFusion
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-8060
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-11.54% / 93.47%
||
7 Day CHG~0.00%
Published-20 Aug, 2019 | 20:07
Updated-04 Aug, 2024 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Adobe Acrobat and Reader versions 2019.012.20035 and earlier, 2019.012.20035 and earlier, 2017.011.30142 and earlier, 2017.011.30143 and earlier, 2015.006.30497 and earlier, and 2015.006.30498 and earlier have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution .

Action-Not Available
Vendor-Apple Inc.Microsoft CorporationAdobe Inc.
Product-acrobat_dcwindowsmacosacrobat_reader_dcAdobe Acrobat and Reader
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-16100
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-5.34% / 89.84%
||
7 Day CHG~0.00%
Published-07 Jun, 2018 | 02:00
Updated-17 Sep, 2024 | 02:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

dns-sync is a sync/blocking dns resolver. If untrusted user input is allowed into the resolve() method then command injection is possible.

Action-Not Available
Vendor-dns-sync_projectHackerOne
Product-dns-syncdns-sync node module
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-8073
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-12.78% / 93.84%
||
7 Day CHG~0.00%
Published-27 Sep, 2019 | 15:19
Updated-04 Aug, 2024 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ColdFusion 2018- update 4 and earlier and ColdFusion 2016- update 11 and earlier have a Command Injection via Vulnerable component vulnerability. Successful exploitation could lead to Arbitrary code execution in the context of the current user.

Action-Not Available
Vendor-Adobe Inc.
Product-coldfusionCold Fusion
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-7968
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-19.07% / 95.18%
||
7 Day CHG~0.00%
Published-26 Aug, 2019 | 17:25
Updated-04 Aug, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Adobe Photoshop CC versions 19.1.8 and earlier and 20.0.5 and earlier have a command injection vulnerability. Successful exploitation could lead to arbitrary code execution.

Action-Not Available
Vendor-Apple Inc.Microsoft CorporationAdobe Inc.
Product-windowsphotoshop_ccmacosAdobe Photoshop CC
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-7537
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.54% / 87.40%
||
7 Day CHG~0.00%
Published-21 Mar, 2019 | 19:55
Updated-04 Aug, 2024 | 20:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Donfig 0.3.0. There is a vulnerability in the collect_yaml method in config_obj.py. It can execute arbitrary Python commands, resulting in command execution.

Action-Not Available
Vendor-pytrolln/a
Product-donfign/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-3271
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
ShareView Details
Matching Score-4
Assigner-Protect AI (formerly huntr.dev)
CVSS Score-9.8||CRITICAL
EPSS-2.27% / 84.32%
||
7 Day CHG~0.00%
Published-16 Apr, 2024 | 00:00
Updated-30 Jul, 2025 | 00:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection in run-llama/llama_index

A command injection vulnerability exists in the run-llama/llama_index repository, specifically within the safe_eval function. Attackers can bypass the intended security mechanism, which checks for the presence of underscores in code generated by LLM, to execute arbitrary code. This is achieved by crafting input that does not contain an underscore but still results in the execution of OS commands. The vulnerability allows for remote code execution (RCE) on the server hosting the application.

Action-Not Available
Vendor-llamaindexrun-llamarun-llama
Product-llamaindexrun-llama/llama_indexllama_index
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-7850
Matching Score-4
Assigner-Adobe Systems Incorporated
ShareView Details
Matching Score-4
Assigner-Adobe Systems Incorporated
CVSS Score-9.8||CRITICAL
EPSS-11.57% / 93.47%
||
7 Day CHG~0.00%
Published-18 Jul, 2019 | 21:43
Updated-04 Aug, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Adobe Campaign Classic version 18.10.5-8984 and earlier versions have a Command injection vulnerability. Successful exploitation could lead to Arbitrary Code Execution in the context of the current user.

Action-Not Available
Vendor-n/aAdobe Inc.Linux Kernel Organization, IncMicrosoft Corporation
Product-windowscampaignlinux_kernelAdobe Campaign
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-13071
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-0.91% / 75.43%
||
7 Day CHG~0.00%
Published-22 Nov, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

QNAP has already patched this vulnerability. This security concern allows a remote attacker to run arbitrary commands on the QNAP Video Station 5.1.3 (for QTS 4.3.3), 5.2.0 (for QTS 4.3.4), and earlier.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-qtsvideo_stationVideo Station
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2008-7319
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.79% / 91.77%
||
7 Day CHG~0.00%
Published-07 Nov, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Net::Ping::External extension through 0.15 for Perl does not properly sanitize arguments (e.g., invalid hostnames) containing shell metacharacters before use of backticks in External.pm, allowing for shell command injection and arbitrary command execution if untrusted input is used.

Action-Not Available
Vendor-net-ping-external_projectn/a
Product-net-ping-externaln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2008-7313
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.46% / 80.53%
||
7 Day CHG~0.00%
Published-31 Mar, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The _httpsrequest function in Snoopy allows remote attackers to execute arbitrary commands. NOTE: this issue exists dues to an incomplete fix for CVE-2008-4796.

Action-Not Available
Vendor-snoopyn/aRed Hat, Inc.Nagios Enterprises, LLC
Product-snoopynagiosopenstackn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-27077
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-15.65% / 94.54%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /cgi-bin/uploadWeiXinPic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-27083
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-14.06% / 94.19%
||
7 Day CHG~0.00%
Published-23 Mar, 2022 | 23:25
Updated-03 Aug, 2024 | 05:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /cgi-bin/uploadAccessCodePic.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-m3m3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45618
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 80.98%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.64, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RAX120 before 1.2.0.16, RBS50Y before 1.0.0.56, WNR2000v5 before 1.0.0.76, XR450 before 2.3.2.114, XR500 before 2.3.2.114, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, EX6410 before 1.0.0.134, RBR10 before 2.6.1.44, RBR20 before 2.6.2.104, RBR40 before 2.6.2.104, RBR50 before 2.7.2.102, EX6420 before 1.0.0.134, RBS10 before 2.6.1.44, RBS20 before 2.6.2.104, RBS40 before 2.6.2.104, RBS50 before 2.7.2.102, EX6400v2 before 1.0.0.134, RBK12 before 2.6.1.44, RBK20 before 2.6.2.104, RBK40 before 2.6.2.104, and RBK50 before 2.7.2.102.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbk12ex6150v2_firmwarer8900_firmwarerbr40_firmwareex6410ex6420_firmwareex7300v2_firmwarewnr2000v5_firmwareex6250_firmwarexr500_firmwarexr700_firmwarexr450_firmwareex7300rbk12_firmwarerbs40rbs50y_firmwarer8900r9000_firmwarerbs40_firmwarerbr10rbs10_firmwareex6410_firmwarerbs20rbs50_firmwarerbs50yr9000ex6200v2_firmwareex6400v2ex6100v2ex7700_firmwarer7800rax120_firmwarerbs10wnr2000v5r7800_firmwareex6100v2_firmwarerbk20_firmwareex6400xr700xr450ex6200v2rbk20ex6400_firmwareex7300_firmwarerbs20_firmwared7800ex6150v2ex8000rbk40ex7320_firmwarerbr20rbk40_firmwarerax120xr500ex6400v2_firmwareex6420ex7300v2d7800_firmwareex8000_firmwareex6250rbr10_firmwarerbr40rbs50rbr50_firmwarerbr50ex7700lbr20rbr20_firmwareex7320rbk50lbr20_firmwarerbk50_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45621
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 80.98%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80r6300v2_firmwarerax15lax20r6400_firmwarer6300v2r7100lgex3700rax50r6900p_firmwareex7500_firmwarer7100lg_firmwarerax45r8300r8500_firmwarers400r7960prax40v2_firmwarer7000_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwareex6130r7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750rbs850_firmwarer6400v2rbr850rax43rax80_firmwarer7000cbr750_firmwarecbr40rbk752_firmwareex3800r7900_firmwareex3700_firmwareex7000_firmwareex6120rbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80xr1000ex7500rs400_firmwarer8000rax75ex7000r6900pex3800_firmwarer7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarer8500ex6130_firmwarerbs750_firmwarer7850_firmwaremr60_firmwarer8300_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarer6400ex6120_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45619
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.02% / 76.85%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR1020 before 2.6.3.58, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RBS50Y before 2.7.3.22, WNR2000v5 before 1.0.0.76, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, RAX10 before 1.0.2.88, RAX120 before 1.2.0.16, RAX70 before 1.0.2.88, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, R6700AX before 1.0.2.88, RAX120v2 before 1.2.0.16, RAX78 before 1.0.2.88, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR350 before 4.3.4.7, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS350 before 4.3.4.7, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK352 before 4.3.4.7, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax70rbk12rbk50_firmwareex6150v2_firmwarer8900_firmwarerbr40_firmwarerbr350_firmwareex6410ex6420_firmwareex7300v2_firmwarewnr2000v5_firmwareex6250_firmwarerbk352xr700_firmwareex7300rbk12_firmwarerax10rax120v2rbs40rbs50y_firmwarer8900rbs40_firmwarer9000_firmwarerbr10rax78_firmwarerbs10_firmwareex6410_firmwarelbr1020_firmwarerbs20rbs50_firmwarerbs50yr9000ex6200v2_firmwareex6400v2ex6100v2ex7700_firmwarer7800rax120_firmwarerbs10wnr2000v5r7800_firmwareex6100v2_firmwarerbk20_firmwarelbr1020xr700ex6400ex6200v2rbk20ex6400_firmwareex7300_firmwarerbs20_firmwareex6150v2r6700axrax120v2_firmwareex8000rbk40ex7320_firmwarerbr20rax78rax70_firmwarerbk40_firmwarerax120rax10_firmwareex6400v2_firmwareex6420ex7300v2ex8000_firmwareex6250rbr10_firmwarerbr40rbs50rbs350rbr50_firmwarerbr50ex7700lbr20rbr20_firmwareex7320rbk352_firmwarerbk50rbr350lbr20_firmwarerbs350_firmwarer6700ax_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45612
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.60% / 68.97%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20rax50r6900p_firmwareex7500_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80ex7500xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-5413
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-1.95% / 83.14%
||
7 Day CHG-0.08%
Published-17 Mar, 2019 | 19:36
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An attacker can use the format parameter to inject arbitrary commands in the npm package morgan < 1.9.1.

Action-Not Available
Vendor-morgan_projectn/a
Product-morganmorgan
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45613
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 80.98%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-xr1000_firmwarecbr40_firmwarerax80xr1000rax15rax75lax20mk62rax50rbs850d7000v2ms60_firmwarerax45rax40v2_firmwarerbr750ms80rax20rax200lax20_firmwarerax20_firmwarerax200_firmwarerbs750_firmwaremk62_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750d7000v2_firmwaremr60_firmwarerbs850_firmwarerbr850rax43rax80_firmwarerbr750_firmwarecbr750_firmwarems80_firmwarecbr40rbk752_firmwarerax35v2_firmwarerbk752rbs750rax15_firmwaremr80_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852ms60rbr850_firmwaremr80n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44882
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-8.90% / 92.38%
||
7 Day CHG+0.22%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DIR_878_FW1.30B08_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45738
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-25.81% / 96.13%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function UploadFirmwareFile. This vulnerability allows attackers to execute arbitrary commands via the parameter FileName.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45733
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-25.81% / 96.13%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function NTPSyncWithHost. This vulnerability allows attackers to execute arbitrary commands via the parameter host_time.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-8404
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-24.54% / 95.99%
||
7 Day CHG~0.00%
Published-02 Jul, 2019 | 18:47
Updated-05 Aug, 2024 | 16:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x0008F598 which calls the "mailLoginTest" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dcs-1130dcs-1130_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-5390
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.8||CRITICAL
EPSS-20.35% / 95.38%
||
7 Day CHG~0.00%
Published-05 Jun, 2019 | 14:55
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote command injection vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.

Action-Not Available
Vendor-n/aHP Inc.
Product-intelligent_management_centerHPE Intelligent Management Center (IMC) PLAT
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-0007
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 62.36%
||
7 Day CHG~0.00%
Published-10 Jan, 2018 | 22:00
Updated-05 Aug, 2024 | 03:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to the local segment, through a local segment broadcast, may be able to cause a Junos device to enter an improper boundary check condition allowing a memory corruption to occur, leading to a denial of service. Further crafted packets may be able to sustain the denial of service condition. Score: 6.5 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) Further, if the attacker is authenticated on the target device receiving and processing the malicious LLDP packet, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over the target device thereby elevating their permissions and privileges, and taking control of the device. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to one or more local segments, via LLDP proxy / tunneling agents or other LLDP through Layer 3 deployments, through one or more local segment broadcasts, may be able to cause multiple Junos devices to enter an improper boundary check condition allowing a memory corruption to occur, leading to multiple distributed Denials of Services. These Denials of Services attacks may have cascading Denials of Services to adjacent connected devices, impacts network devices, servers, workstations, etc. Further crafted packets may be able to sustain these Denials of Services conditions. Score 6.8 MEDIUM (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H) Further, if the attacker is authenticated on one or more target devices receiving and processing these malicious LLDP packets, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over multiple target devices thereby elevating their permissions and privileges, and taking control multiple devices. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H) Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71; 12.3 versions prior to 12.3R12-S7; 12.3X48 versions prior to 12.3X48-D55; 14.1 versions prior to 14.1R8-S5, 14.1R9; 14.1X53 versions prior to 14.1X53-D46, 14.1X53-D50, 14.1X53-D107; 14.2 versions prior to 14.2R7-S9, 14.2R8; 15.1 versions prior to 15.1F2-S17, 15.1F5-S8, 15.1F6-S8, 15.1R5-S7, 15.1R7; 15.1X49 versions prior to 15.1X49-D90; 15.1X53 versions prior to 15.1X53-D65; 16.1 versions prior to 16.1R4-S6, 16.1R5; 16.1X65 versions prior to 16.1X65-D45; 16.2 versions prior to 16.2R2; 17.1 versions prior to 17.1R2. No other Juniper Networks products or platforms are affected by this issue.

Action-Not Available
Vendor-n/aJuniper Networks, Inc.
Product-junosn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2017-4918
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-9.8||CRITICAL
EPSS-3.01% / 86.28%
||
7 Day CHG~0.00%
Published-08 Jun, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Horizon View Client (2.x, 3.x and 4.x prior to 4.5.0) contains a command injection vulnerability in the service startup script. Successful exploitation of this issue may allow unprivileged users to escalate their privileges to root on the Mac OSX system where the client is installed.

Action-Not Available
Vendor-VMware (Broadcom Inc.)
Product-horizon_viewHorizon View Client for Mac
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-4045
Matching Score-4
Assigner-Spanish National Cybersecurity Institute, S.A. (INCIBE)
ShareView Details
Matching Score-4
Assigner-Spanish National Cybersecurity Institute, S.A. (INCIBE)
CVSS Score-9.8||CRITICAL
EPSS-89.44% / 99.53%
||
7 Day CHG+1.01%
Published-07 Mar, 2022 | 21:58
Updated-17 Sep, 2024 | 02:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TP-LINK Tapo C200 remote code execution vulnerability

TP-Link Tapo C200 IP camera, on its 1.1.15 firmware version and below, is affected by an unauthenticated RCE vulnerability, present in the uhttpd binary running by default as root. The exploitation of this vulnerability allows an attacker to take full control of the camera.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-tapo_c200_firmwaretapo_c200Tapo C200
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-25029
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-2.41% / 84.77%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 18:45
Updated-05 Aug, 2024 | 03:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Versa Director, the command injection is an attack in which the goal is execution of arbitrary commands on the host operating system via a vulnerable application. Command injection attacks are possible when an application passes unsafe user supplied data (forms, cookies, HTTP headers etc.) to a system shell. In this attack, the attacker-supplied operating system commands are usually executed with the privileges of the vulnerable application. Command injection attacks are possible largely due to insufficient input validation.

Action-Not Available
Vendor-n/aVersa Networks, Inc.
Product-versa_directorVersa Director
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38527
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.1||HIGH
EPSS-2.46% / 84.90%
||
7 Day CHG~0.00%
Published-11 Aug, 2021 | 00:01
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwarerbk12rbw30_firmwarerbr40_firmwarerbw30ex6410ex6420_firmwareex6250_firmwarexr500_firmwareex7300rbk12_firmwarerbs40rbs50y_firmwarerbs40_firmwarerbr10rbs850_firmwarerbs10_firmwarerbr850ex6410_firmwarerbs20rbs50_firmwareex6150rbs50ycbr40ex7700_firmwarer7800rbk752_firmwarerbs10r7800_firmwarerbk852rbk20_firmwareex6400ex6150_firmwarerbs40v_firmwarerbk20ex6400_firmwareex7300_firmwarerbs20_firmwareex8000rbk40ex7320_firmwarerbr20rbs850rbr750rbk40_firmwarexr500ex6100ex6420rbs40vex8000_firmwareex6250rbs750_firmwarerbr10_firmwarerbr750_firmwarerbr40rbs50rbr50_firmwarerbr50ex7700rbk752rbs750ex6100_firmwarerbr20_firmwareex7320rbk50rbk852_firmwarerbk50_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38528
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.93% / 86.11%
||
7 Day CHG~0.00%
Published-11 Aug, 2021 | 00:00
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D8500 before 1.0.3.58, R6900P before 1.3.2.132, R7000P before 1.3.2.132, R7100LG before 1.0.0.64, WNDR3400v3 before 1.0.1.38, and XR300 before 1.0.3.56.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-xr300_firmwarer7100lg_firmwared8500wndr3400_firmwarer6900p_firmwarexr300r6900pwndr3400r7100lgd8500_firmwarer7000pr7000p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-19875
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 71.47%
||
7 Day CHG~0.00%
Published-27 Nov, 2020 | 16:21
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.

Action-Not Available
Vendor-n/aB&R Industrial Automation GmbH
Product-industrial_automation_aproln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-33963
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.83% / 82.57%
||
7 Day CHG~0.00%
Published-15 Jan, 2022 | 09:16
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

China Mobile An Lianbao WF-1 v1.0.1 router web interface through /api/ZRMacClone/mac_addr_clone receives parameters by POST request, and the parameter macType has a command injection vulnerability. An attacker can use the vulnerability to execute remote commands.

Action-Not Available
Vendor-chinamobilen/a
Product-an_lianbao_wf-1an_lianbao_wf-1_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-18780
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.40% / 90.81%
||
7 Day CHG~0.00%
Published-05 Nov, 2019 | 19:05
Updated-05 Aug, 2024 | 02:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An arbitrary command injection vulnerability in the Cluster Server component of Veritas InfoScale allows an unauthenticated remote attacker to execute arbitrary commands as root or administrator. These Veritas products are affected: Access 7.4.2 and earlier, Access Appliance 7.4.2 and earlier, Flex Appliance 1.2 and earlier, InfoScale 7.3.1 and earlier, InfoScale between 7.4.0 and 7.4.1, Veritas Cluster Server (VCS) 6.2.1 and earlier on Linux/UNIX, Veritas Cluster Server (VCS) 6.1 and earlier on Windows, Storage Foundation HA (SFHA) 6.2.1 and earlier on Linux/UNIX, and Storage Foundation HA (SFHA) 6.1 and earlier on Windows.

Action-Not Available
Vendor-n/aVeritas Technologies LLCLinux Kernel Organization, IncMicrosoft Corporation
Product-infoscalelinux_kernelcluster_serverstorage_foundation_haflex_appliancewindowsaccessaccess_appliancen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-15609
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-5.00% / 89.48%
||
7 Day CHG~0.00%
Published-28 Feb, 2020 | 19:30
Updated-05 Aug, 2024 | 00:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The kill-port-process package version < 2.2.0 is vulnerable to a Command Injection vulnerability.

Action-Not Available
Vendor-kill-port-process_projectn/a
Product-kill-port-processkill-port-process
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45614
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.92% / 75.61%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-xr1000_firmwarerax80xr1000rax15rax75lax20mk62rax50rbs850d7000v2ms60_firmwarerax45rax40v2_firmwarerbr750rax20rax200lax20_firmwarerax20_firmwarerax200_firmwarerbs750_firmwaremk62_firmwaremr60rax35v2rax43_firmwarerax40v2mr60_firmwared7000v2_firmwarerbs850_firmwarerbr850rax43rax80_firmwarerbr750_firmwarerbk752_firmwarerax35v2_firmwarerbk752rbs750rax15_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852ms60rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45616
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 80.98%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax15lax20rax50r6900p_firmwarer7960prax45rs400r7000_firmwarerax40v2_firmwarerax20r7900prax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarerbk752_firmwarer7900_firmwarerbk852r7900p_firmwarelax20_firmwarems60r8000_firmwarexr1000_firmwarerax80xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarerbr750_firmwarer7000prax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44881
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-8.90% / 92.38%
||
7 Day CHG+0.22%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_firmwaredir-882n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45622
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.67% / 85.47%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20r6400_firmwarerax50r6900p_firmwareex7500_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80ex7500xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarer6400rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11217
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.81% / 91.13%
||
7 Day CHG~0.00%
Published-24 Apr, 2019 | 19:13
Updated-04 Aug, 2024 | 22:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The GitController in Jakub Chodounsky Bonobo Git Server before 6.5.0 allows execution of arbitrary commands in the context of the web server via a crafted http request.

Action-Not Available
Vendor-bonobogitservern/a
Product-bonobo_git_servern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11535
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.36% / 87.07%
||
7 Day CHG~0.00%
Published-17 Jul, 2019 | 19:35
Updated-04 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unsanitized user input in the web interface for Linksys WiFi extender products (RE6400 and RE6300 through 1.2.04.022) allows for remote command execution. An attacker can access system OS configurations and commands that are not intended for use beyond the web UI.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-re6400re6300_firmwarere6300re6400_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11076
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-16.99% / 94.82%
||
7 Day CHG~0.00%
Published-23 Apr, 2019 | 17:32
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cribl UI 1.5.0 allows remote attackers to run arbitrary commands via an unauthenticated web request.

Action-Not Available
Vendor-cribln/a
Product-cribln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-10095
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-3.02% / 86.31%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 00:00
Updated-04 Aug, 2024 | 22:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
bash command injection in spark interpreter

bash command injection vulnerability in Apache Zeppelin allows an attacker to inject system commands into Spark interpreter settings. This issue affects Apache Zeppelin Apache Zeppelin version 0.9.0 and prior versions.

Action-Not Available
Vendor-The Apache Software Foundation
Product-zeppelinApache Zeppelin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-9866
Matching Score-4
Assigner-SonicWall, Inc.
ShareView Details
Matching Score-4
Assigner-SonicWall, Inc.
CVSS Score-9.8||CRITICAL
EPSS-11.23% / 93.34%
||
7 Day CHG-0.52%
Published-03 Aug, 2018 | 20:00
Updated-05 May, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in lack of validation of user-supplied parameters pass to XML-RPC calls on SonicWall Global Management System (GMS) virtual appliance's, allow remote user to execute arbitrary code. This vulnerability affected GMS version 8.1 and earlier.

Action-Not Available
Vendor-SonicWall Inc.
Product-global_management_systemGlobal Management System (GMS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
  • Previous
  • 1
  • 2
  • 3
  • 4
  • Next
Details not found