The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
Battelle V2I Hub 2.5.1 contains hard-coded credentials for the administrative account. An attacker could exploit this vulnerability to log in as an admin on any installation and gain unauthorized access to the system.
Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.
Directus 6.4.9 has a hardcoded admin password for the Admin account because of an INSERT statement in api/schema.sql.
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Hardcoded credentials exist for an unprivileged SSH account with a shell of /bin/false.
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
A vulnerability in the Cluster Manager of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to log in to an affected system using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the root account. An attacker could exploit this vulnerability by using the account to log in to an affected system. An exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user. Cisco Bug IDs: CSCvh02680.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
Juniper Networks Contrail Service Orchestration releases prior to 4.0.0 have Grafana service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Grafana or exploit other weaknesses or vulnerabilities in Grafana.
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 have Cassandra service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Cassandra.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone.
Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account.
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
The SSH server in Cisco Unified IP Phone 7906G, 7911G, 7941G, 7961G, 7970G, and 7971G, with firmware 8.0(4)SR1 and earlier, uses a hard-coded username and password, which allows remote attackers to access the device.
Multiple hardcoded credentials in Xsuite 2.x.
The server API in the Anda app relies on hardcoded credentials.
Intellinet NFC-30ir IP Camera has a vendor backdoor that can allow a remote attacker access to a vendor-supplied CGI script in the web directory.
A design flaw in the Trane ComfortLink II SCC firmware version 2.0.2 service allows remote attackers to take complete control of the system.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
iBaby M3S has a password of admin for the backdoor admin account.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
The factory configuration for vMX installations, as shipped, includes default credentials for the root account. Without proper modification of these default credentials by the administrator, an attacker could exploit these credentials and access the vMX instance without authorization. This issue affects Juniper Networks Junos OS: 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on vMX; 17.2 versions prior to 17.2R3-S3 on vMX; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on vMX; 17.4 versions prior to 17.4R2-S9, 17.4R3 on vMX; 18.1 versions prior to 18.1R3-S9 on vMX; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on vMX; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D60 on vMX; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on vMX; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on vMX; 19.1 versions prior to 19.1R1-S4, 19.1R2, 19.1R3 on vMX; 19.2 versions prior to 19.2R1-S3, 19.2R2 on vMX; 19.3 versions prior to 19.3R1-S1, 19.3R2 on vMX.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to login to the Management page and change the configuration.
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to read/send mail or change the configuration.
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Telesquare SDT-CS3B1 and SDT-CW3B1 devices through 1.2.0 have a default factory account. Remote attackers can obtain access to the device via TELNET using a hardcoded account.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not).
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
Dr. ID Door Access Control and Personnel Attendance Management system uses the hard-code admin default credentials that allows remote attackers to access the system through the default password and obtain the highest permission.
A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.