Cisco ONS15454 and ONS15327 running ONS before 3.4 stores usernames and passwords in cleartext in the image database for the TCC, TCC+ or XTC, which could allow attackers to gain privileges by obtaining the passwords from the image database or a backup.
Cisco Unified Computing System (UCS) Platform Emulator 2.5(2)TS4, 3.0(2c)A, and 3.0(2c)TS9 allows local users to gain privileges via crafted arguments on a ucspe-copy command line, aka Bug ID CSCux68832.
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command and gain unauthorized access to the underlying operating system of the device. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow an attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules, Unified Computing System Manager. Cisco Bug IDs: CSCvf14923, CSCvf14926, CSCvg04095.
A vulnerability in the Open Agent Container (OAC) feature of Cisco Nexus Series Switches could allow an unauthenticated, local attacker to read and send packets outside the scope of the OAC. The vulnerability is due to insufficient internal security measures in the OAC feature. An attacker could exploit this vulnerability by crafting specific packets for communication on the device-internal network. A successful exploit could allow the attacker to run code on the underlying host operating system. OAC is not enabled by default. For a device to be vulnerable, an administrator would need to install and activate this feature. This vulnerability affects the following Cisco Nexus Series Switches: Nexus 2000 Series Fabric Extenders, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches. Cisco Bug IDs: CSCve53542, CSCvf36621.
A vulnerability in the routine that loads DLL files in Cisco Meeting App for Windows could allow an authenticated, local attacker to run an executable file with privileges equivalent to those of Cisco Meeting App. The vulnerability is due to incomplete input validation of the path name for DLL files before they are loaded. An attacker could exploit this vulnerability by installing a crafted DLL file in a specific system directory. A successful exploit could allow the attacker to execute commands on the underlying Microsoft Windows host with privileges equivalent to those of Cisco Meeting App. The attacker would need valid user credentials to exploit this vulnerability. Cisco Bug IDs: CSCvd77907.
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments to the CLI parser. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow the attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode, Nexus 9000 Series Switches in standalone NX-OS mode, and Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve99925, CSCvf15164, CSCvf15167, CSCvf15170, CSCvf15173.
A vulnerability in the TCL scripting subsystem of Cisco NX-OS System Software could allow an authenticated, local attacker to escape the interactive TCL shell and gain unauthorized access to the underlying operating system of the device. The vulnerability exists due to insufficient input validation of user-supplied files passed to the interactive TCL shell of the affected device. An attacker could exploit this vulnerability to escape the scripting sandbox and execute arbitrary commands on the underlying operating system with the privileges of the authenticated user. To exploit this vulnerability, an attacker must have local access and be authenticated to the targeted device with administrative or tclsh execution privileges. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules, Unified Computing System Manager. Cisco Bug IDs: CSCve93750, CSCve93762, CSCve93763, CSCvg04127.
A vulnerability in the restricted shell of the Cisco Identity Services Engine (ISE) that is accessible via SSH could allow an authenticated, local attacker to run arbitrary CLI commands with elevated privileges. The vulnerability is due to incomplete input validation of the user input for CLI commands issued at the restricted shell. An attacker could exploit this vulnerability by authenticating to the targeted device and executing commands that could lead to elevated privileges. An attacker would need valid user credentials to the device to exploit this vulnerability. The vulnerability affects the following Cisco Identity Services Engine (ISE) products running Release 1.4, 2.0, 2.0.1, 2.1.0: ISE, ISE Express, ISE Virtual Appliance. Cisco Bug IDs: CSCve74916.
A vulnerability in the guest shell feature of Cisco NX-OS System Software could allow an authenticated, local attacker to read and send packets outside the scope of the guest shell container. An attacker would need valid administrator credentials to perform this attack. The vulnerability is due to insufficient internal security measures in the guest shell feature. An attacker could exploit this vulnerability by sending or receiving packets on the device-internal network outside of the guest shell container, aka "Unauthorized Internal Interface Access." This vulnerability affects the following products running Cisco NX-OS System Software: Nexus 3000 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvf33038.
A vulnerability in Cisco NX-OS System Software running on Cisco MDS Multilayer Director Switches, Cisco Nexus 7000 Series Switches, and Cisco Nexus 7700 Series Switches could allow an authenticated, local attacker to access the Bash shell of an affected device's operating system, even if the Bash shell is disabled on the system. The vulnerability is due to insufficient sanitization of user-supplied parameters that are passed to certain functions of the Python scripting sandbox of the affected system. An attacker could exploit this vulnerability to escape the scripting sandbox and enter the Bash shell of the operating system with the privileges of the authenticated user for the affected system. To exploit this vulnerability, the attacker must have local access to the affected system and be authenticated to the affected system with administrative or Python execution privileges. Cisco Bug IDs: CSCvd86513.
The Cisco AMP For Endpoints application allows an authenticated, local attacker to access a static key value stored in the local application software. The vulnerability is due to the use of a static key value stored in the application used to encrypt the connector protection password. An attacker could exploit this vulnerability by gaining local, administrative access to a Windows host and stopping the Cisco AMP for Endpoints service. Cisco Bug IDs: CSCvg42904.
A vulnerability in the Cisco FindIT Network Discovery Utility could allow an authenticated, local attacker to perform a DLL preloading attack, potentially causing a partial impact to device availability, confidentiality, and integrity. The vulnerability is due to the application loading a malicious copy of a specific, nondefined DLL file instead of the DLL file it was expecting. An attacker could exploit this vulnerability by placing an affected DLL within the search path of the host system. An exploit could allow the attacker to load a malicious DLL file into the system, thus partially compromising confidentiality, integrity, and availability on the device. Cisco Bug IDs: CSCve89785.
A vulnerability in the CLI of Cisco NX-OS System Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments to the CLI parser. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command and gaining unauthorized access to the underlying operating system of the device. An exploit could allow the attacker to execute arbitrary commands at the user's privilege level. On products that support multiple virtual device contexts (VDCs), this vulnerability could allow an attacker to execute commands at the user's privilege level outside the user's environment. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 2000 Series Fabric Extenders, Nexus 3000 Series Switches, Nexus 5000 Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCve99902, CSCvf14879.
A vulnerability in Cisco NX-OS System Software could allow an authenticated, local attacker to bypass signature verification when loading a software image. The vulnerability is due to insufficient NX-OS signature verification for software images. An authenticated, local attacker could exploit this vulnerability to bypass signature verification and load a crafted, unsigned software image on a targeted device. The attacker would need valid administrator credentials to perform this exploit. This vulnerability affects the following products running Cisco NX-OS System Software: Multilayer Director Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Unified Computing System Manager. Cisco Bug IDs: CSCvf25045, CSCvf31495.
A vulnerability in the Cisco Unified Computing System (UCS) Manager, Cisco Firepower 4100 Series Next-Generation Firewall (NGFW), and Cisco Firepower 9300 Security Appliance could allow an authenticated, local attacker to obtain root shell privileges on the device, aka Command Injection. The vulnerability is due to improper validation of string input in the shell application. An attacker could exploit this vulnerability through the use of malicious commands. A successful exploit could allow the attacker to obtain root shell privileges on the device. Cisco Bug IDs: CSCvf20741, CSCvf60078.
A vulnerability in the Cisco FindIT Network Discovery Utility could allow an authenticated, local attacker to perform a DLL preloading attack, potentially causing a partial impact to the device availability, confidentiality, and integrity, aka Insecure Library Loading. The vulnerability is due to the application loading a malicious copy of a specific, nondefined DLL file instead of the DLL file it was expecting. An attacker could exploit this vulnerability by placing an affected DLL within the search path of the host system. An exploit could allow the attacker to load a malicious DLL file into the system, thus partially compromising confidentiality, integrity, and availability on the device. Cisco Bug IDs: CSCvf37955.
tac_plus Tacacs+ daemon F4.0.4.alpha, originally maintained by Cisco, creates files from the accounting directive with world-readable and writable permissions, which allows local users to access and modify sensitive files.
A vulnerability in the local management (local-mgmt) CLI of Cisco FXOS Software and Cisco UCS Manager Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system (OS) of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by including crafted arguments to specific commands. A successful exploit could allow the attacker to execute arbitrary commands on the underlying OS with the privileges of the currently logged-in user for all affected platforms excluding Cisco UCS 6400 Series Fabric Interconnects. On Cisco UCS 6400 Series Fabric Interconnects, the injected commands are executed with root privileges.
Cisco Firepower Management Center 6.0.1 has hardcoded database credentials, which allows local users to obtain sensitive information by leveraging CLI access, aka Bug ID CSCva30370.
A vulnerability in the installation procedure of the Cisco Hybrid Media Service could allow an authenticated, local attacker to elevate privileges to the root level. More Information: CSCvb81344. Known Affected Releases: 1.0.
Cisco IOS XR 6.1.1 allows local users to execute arbitrary OS commands as root by leveraging admin privileges, aka Bug ID CSCva38349.
A vulnerability in the command-line interface of the Cisco IP Interoperability and Collaboration System (IPICS) could allow an authenticated, local attacker to elevate the privilege level associated with their session. More Information: CSCva38636. Known Affected Releases: 4.10(1). Known Fixed Releases: 5.0(1).
Cisco Aironet 1800, 2800, and 3800 devices with software before 8.2.110.0, 8.2.12x before 8.2.121.0, and 8.3.x before 8.3.102.0 allow local users to gain privileges via crafted CLI parameters, aka Bug ID CSCuz24725.
iox in Cisco IOS, possibly 15.6 and earlier, and IOS XE, possibly 3.18 and earlier, allows local users to execute arbitrary IOx Linux commands on the guest OS via crafted iox command-line options, aka Bug ID CSCuz59223.
The installation procedure on Cisco Application Policy Infrastructure Controller (APIC) devices 1.3(2f) mishandles binary files, which allows local users to obtain root access via unspecified vectors, aka Bug ID CSCva50496.
Cisco AnyConnect Secure Mobility Client before 4.2.05015 and 4.3.x before 4.3.02039 mishandles pathnames, which allows local users to gain privileges via a crafted INF file, aka Bug ID CSCuz92464.
UCS Manager and UCS 6200 Fabric Interconnects in Cisco Unified Computing System (UCS) through 3.0(2d) allow local users to obtain OS root access via crafted CLI input, aka Bug ID CSCuz91263.
Untrusted search path vulnerability in Cisco WebEx Productivity Tools 2.40.5001.10012 allows local users to gain privileges via a Trojan horse cryptsp.dll, dwmapi.dll, msimg32.dll, ntmarta.dll, propsys.dll, riched20.dll, rpcrtremote.dll, secur32.dll, sxs.dll, or uxtheme.dll file in the current working directory, aka Bug ID CSCuy56140.
Cisco Prime Network Analysis Module (NAM) before 6.1(1) patch.6.1-2-final and 6.2.x before 6.2(1) and Prime Virtual Network Analysis Module (vNAM) before 6.1(1) patch.6.1-2-final and 6.2.x before 6.2(1) allow local users to obtain root access via crafted CLI input, aka Bug ID CSCuy21892.
CISCO IP 8800 phones with software 11.0.1 and earlier allow local users to gain privileges for OS command execution via crafted CLI commands, aka Bug ID CSCuz03005.
The CLI in Cisco IOS XR 6.x through 6.0.1 allows local users to execute arbitrary OS commands in a privileged context by leveraging unspecified container access, aka Bug ID CSCuz62721.
The installation component on Cisco Application Policy Infrastructure Controller (APIC) devices with software before 1.3(2f) mishandles binary files, which allows local users to obtain root access via unspecified vectors, aka Bug ID CSCuz72347.
Cisco Aironet Access Point Software 8.2(100.0) on 1830e, 1830i, 1850e, 1850i, 2800, and 3800 access points allows local users to obtain Linux root access via crafted CLI command parameters, aka Bug ID CSCuy64037.
The CLI command parser on Cisco RV110W, RV130W, and RV215W devices allows local users to execute arbitrary shell commands as an administrator via crafted parameters, aka Bug IDs CSCuv90134, CSCux58161, and CSCux73567.
Cisco Application Policy Infrastructure Controller (APIC) 1.1j allows local users to gain privileges via vectors involving addition of an SSH key, aka Bug ID CSCuw46076.
The CLI parser in Cisco NX-OS 4.1(2)E1(1), 6.2(11b), 6.2(12), 7.2(0)ZZ(99.1), 7.2(0)ZZ(99.3), and 9.1(1)SV1(3.1.8) on Nexus devices allows local users to execute arbitrary OS commands via crafted characters in a filename, aka Bug IDs CSCuv08491, CSCuv08443, CSCuv08480, CSCuv08448, CSCuu99291, CSCuv08434, and CSCuv08436.
Cisco NX-OS 6.2(10) on Nexus and MDS 9000 devices allows local users to execute arbitrary OS commands by entering crafted tar parameters in the CLI, aka Bug ID CSCus44856.
A vulnerability in Cisco AnyConnect Secure Mobility Client for Windows could allow an authenticated, local attacker to install and execute an arbitrary executable file with privileges equivalent to the Microsoft Windows operating system SYSTEM account. More Information: CSCvb68043. Known Affected Releases: 4.3(2039) 4.3(748). Known Fixed Releases: 4.3(4019) 4.4(225).
A vulnerability in Cisco IOS XR Software could allow an authenticated, local attacker to log in to the device with the privileges of the root user. More Information: CSCva38434. Known Affected Releases: 6.1.1.BASE.
A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, local attacker to access the shell of the underlying Linux operating system on the affected device. The vulnerability is due to improper input validation in the affected software. An attacker could exploit this vulnerability by sending crafted commands to the affected device. An exploit could allow the attacker to gain shell access with a nonroot user account to the underlying Linux operating system on the affected device and potentially access system configuration files with sensitive information. This vulnerability only affects console connections from CIMC. It does not apply to remote connections, such as telnet or SSH.
Cisco Secure Desktop (CSD) before 3.1.1.45 allows local users to escape out of the secure desktop environment by using certain applications that switch to the default desktop, aka "System Policy Evasion".
The installation of Cisco Secure Desktop (CSD) before 3.1.1.45 uses insecure default permissions (all users full control) for the CSD directory and its parent directory, which allow local users to gain privileges by replacing CSD executables, aka "Local Privilege Escalation".
A vulnerability in the local-mgmt CLI command of the Cisco Unified Computing System (UCS) Manager, Cisco Firepower 4100 Series Next-Generation Firewall (NGFW), and Cisco Firepower 9300 Security Appliance could allow an authenticated, local attacker to perform a command injection attack. More Information: CSCvb61394 CSCvb86816. Known Affected Releases: 2.0(1.68) 3.1(1k)A. Known Fixed Releases: 92.2(1.101) 92.1(1.1658) 2.0(1.115).
Cisco NAC maintains an exception list that does not record device properties other than MAC address, which allows physically proximate attackers to bypass control methods and join a local network by spoofing the MAC address of a different type of device, as demonstrated by using the MAC address of a disconnected printer.
Unspecified vulnerability in the command line interface (CLI) in Cisco Unified CallManager (CUCM) 5.0(1) through 5.0(3a) allows local users to execute arbitrary commands with elevated privileges via unspecified vectors, involving "certain CLI commands," aka bug CSCse11005.
A vulnerability in the CLI of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into a vulnerable CLI command. An exploit could allow the attacker to read or write arbitrary files at the user's privilege level outside of the user's path. Cisco Bug IDs: CSCvb86787, CSCve60516, CSCve60555.
A vulnerability in Cisco Elastic Services Controller could allow an authenticated, local, unprivileged attacker to access sensitive information, including credentials for system accounts, on an affected system. The vulnerability is due to improper protection of sensitive log files. An attacker could exploit this vulnerability by logging in to an affected system and accessing unprotected log files. A successful exploit could allow the attacker to access sensitive log files, which may include system credentials, on the affected system. Cisco Bug IDs: CSCvc76616. Known Affected Releases: 2.2(9.76).
A vulnerability in the filesystem of Cisco IOS XE Software could allow an authenticated, local attacker within the IOx Guest Shell to modify the namespace container protections on an affected device. The vulnerability is due to insufficient file permissions. An attacker could exploit this vulnerability by modifying files that they should not have access to. A successful exploit could allow the attacker to remove container protections and perform file actions outside the namespace of the container.
The TCL shell in Cisco IOS 12.2(14)S before 12.2(14)S16, 12.2(18)S before 12.2(18)S11, and certain other releases before 25 January 2006 does not perform Authentication, Authorization, and Accounting (AAA) command authorization checks, which may allow local users to execute IOS EXEC commands that were prohibited via the AAA configuration, aka Bug ID CSCeh73049.
Certain Cisco IOS releases in 12.2S based trains with maintenance release number 25 and later, 12.3T based trains, and 12.4 based trains reuse a Tcl Shell process across login sessions of different local users on the same terminal if the first user does not use tclquit before exiting, which may cause subsequent local users to execute unintended commands or bypass AAA command authorization checks, aka Bug ID CSCef77770.