Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:09 Aug, 2017 | 21:00
Updated At:05 Aug, 2024 | 18:51
Rejected At:
▼CVE Numbering Authority (CNA)

Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://extplorer.net/news/21
x_refsource_CONFIRM
Hyperlink: http://extplorer.net/news/21
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://extplorer.net/news/21
x_refsource_CONFIRM
x_transferred
Hyperlink: http://extplorer.net/news/21
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:09 Aug, 2017 | 21:29
Updated At:20 Apr, 2025 | 01:37

Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

extplorer
extplorer
>>extplorer>>Versions up to 2.1.9(inclusive)
cpe:2.3:a:extplorer:extplorer:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://extplorer.net/news/21cve@mitre.org
Release Notes
Vendor Advisory
http://extplorer.net/news/21af854a3a-2127-422b-91ae-364da2661108
Release Notes
Vendor Advisory
Hyperlink: http://extplorer.net/news/21
Source: cve@mitre.org
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://extplorer.net/news/21
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Release Notes
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

455Records found

CVE-2025-8818
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-04 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-0528
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.92% / 75.60%
||
7 Day CHG-4.67%
Published-17 Jan, 2025 | 14:31
Updated-28 May, 2025 | 14:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8/AC10/AC18 HTTP Request telnet command injection

A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac10_firmwareac18_firmwareac18ac10ac8_firmwareac8AC8AC18AC10
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 58.04%
||
7 Day CHG-0.00%
Published-15 Sep, 2025 | 11:02
Updated-19 Sep, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9/AC15 exeCommand formexeCommand os command injection

A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac9_firmwareac9ac15AC9AC15
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.95%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 21:02
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wireless_device_dissoc command injection

A vulnerability was identified in Comfast CF-N1 2.6.0. This vulnerability affects the function wireless_device_dissoc of the file /usr/bin/webmgnt. Such manipulation of the argument mac leads to command injection. The attack may be performed from a remote location. The exploit is publicly available and might be used.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-9793
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-10.00% / 92.91%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 15:31
Updated-01 Nov, 2024 | 14:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC1206 ate ate_ifconfig_set command injection

A vulnerability classified as critical was found in Tenda AC1206 up to 15.03.06.23. This vulnerability affects the function ate_iwpriv_set/ate_ifconfig_set of the file /goform/ate. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac1206_firmwareac1206AC1206ac1206_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.11%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 19:32
Updated-02 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaticRoute os command injection

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re9000_firmwarere6350re6500re6250_firmwarere7000re7000_firmwarere6250re6350_firmwarere9000re6300_firmwarere6500_firmwareRE7000RE9000RE6250RE6350RE6300RE6500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9727
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.08% / 23.80%
||
7 Day CHG~0.00%
Published-31 Aug, 2025 | 11:32
Updated-23 Oct, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816L soap.cgi soapcgi_main os command injection

A weakness has been identified in D-Link DIR-816L 206b01. Affected by this issue is the function soapcgi_main of the file /soap.cgi. This manipulation of the argument service causes os command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-816l_firmwaredir-816lDIR-816L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9575
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:02
Updated-04 Sep, 2025 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 upload.cgi cgiMain os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6500RE9000RE7000RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9149
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.21%
||
7 Day CHG~0.00%
Published-19 Aug, 2025 | 17:32
Updated-06 Oct, 2025 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-NU516U1 wireless.cgi sub_4032E4 command injection

A vulnerability was determined in Wavlink WL-NU516U1 M16U1_V240425. This impacts the function sub_4032E4 of the file /cgi-bin/wireless.cgi. This manipulation of the argument Guest_ssid causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1WL-NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8827
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-04 Sep, 2025 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8823
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 01:05
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setDeviceName os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9654
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-29 Aug, 2025 | 15:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AiondaDotCom mcp-ssh server-simple.mjs command injection

A security flaw has been discovered in AiondaDotCom mcp-ssh up to 1.0.3. Affected by this issue is some unknown functionality of the file server-simple.mjs. Performing manipulation results in command injection. The attack can be initiated remotely. Upgrading to version 1.0.4 and 1.1.0 can resolve this issue. The patch is named cd2566a948b696501abfa6c6b03462cac5fb43d8. It is advisable to upgrade the affected component.

Action-Not Available
Vendor-AiondaDotCom
Product-mcp-ssh
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8937
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.54% / 67.31%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 04:32
Updated-03 Oct, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N350R formSysCmd command injection

A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n350r_firmwaren350rN350R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9585
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.18% / 38.95%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:32
Updated-02 Oct, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wifilith_delete_pic_file command injection

A vulnerability was determined in Comfast CF-N1 2.6.0. This affects the function wifilith_delete_pic_file of the file /usr/bin/webmgnt. This manipulation of the argument portal_delete_picname causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-comfastComfast
Product-cf-n1_firmwarecf-n1CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8210
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.59% / 85.33%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 18:31
Updated-29 Aug, 2024 | 16:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 hd_config.cgi sprintf command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been classified as critical. This affects the function sprintf of the file /cgi-bin/hd_config.cgi. The manipulation of the argument f_mount leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8212
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.59% / 85.33%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 19:31
Updated-29 Aug, 2024 | 15:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 hd_config.cgi cgi_FMT_R12R5_2nd_DiskMGR command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been rated as critical. This issue affects the function cgi_FMT_R12R5_2nd_DiskMGR of the file /cgi-bin/hd_config.cgi. The manipulation of the argument f_source_dev leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8211
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.37% / 84.69%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 19:00
Updated-29 Aug, 2024 | 15:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 hd_config.cgi cgi_FMT_Std2R1_DiskMGR command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been declared as critical. This vulnerability affects the function cgi_FMT_Std2R1_DiskMGR of the file /cgi-bin/hd_config.cgi. The manipulation of the argument f_newly_dev leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-7436
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.37% / 84.70%
||
7 Day CHG~0.00%
Published-03 Aug, 2024 | 14:00
Updated-11 Sep, 2024 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8100 msp_info.htm msp_info_htm command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07. This issue affects the function msp_info_htm of the file msp_info.htm. The manipulation of the argument cmd leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273521 was assigned to this vulnerability.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8100di-8100_firmwareDI-8100di-8100
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7160
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.59% / 87.53%
||
7 Day CHG~0.00%
Published-28 Jul, 2024 | 15:00
Updated-08 Aug, 2024 | 11:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3700R cstecgi.cgi setWanCfg command injection

A vulnerability classified as critical has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-a3700ra3700r_firmwareA3700Ra3700r_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7788
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.17% / 38.30%
||
7 Day CHG-0.01%
Published-18 Jul, 2025 | 15:02
Updated-11 Sep, 2025 | 19:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Xuxueli xxl-job SampleXxlJob.java commandJobHandler os command injection

A vulnerability has been found in Xuxueli xxl-job up to 3.1.1 and classified as critical. Affected by this vulnerability is the function commandJobHandler of the file src\main\java\com\xxl\job\executor\service\jobhandler\SampleXxlJob.java. The manipulation leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-xuxueliXuxueli
Product-xxl-jobxxl-job
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8132
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-23.55% / 95.87%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 18:00
Updated-27 Aug, 2024 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request webdav_mgr.cgi webdav_mgr command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been classified as critical. This affects the function webdav_mgr of the file /cgi-bin/webdav_mgr.cgi of the component HTTP POST Request Handler. The manipulation of the argument f_path leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-343_firmwarednr-202l_firmwaredns-320lw_firmwaredns-323_firmwaredns-320_firmwaredns-315l_firmwaredns-321_firmwaredns-320l_firmwarednr-322l_firmwaredns-325_firmwaredns-120_firmwaredns-326_firmwaredns-1550-04_firmwaredns-726-4_firmwaredns-1200-05_firmwaredns-340l_firmwaredns-1100-4_firmwarednr-326_firmwaredns-345_firmwaredns-327l_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8665
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.84%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 17:02
Updated-06 Aug, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agno-agi agno Model Context Protocol mcp.py MultiMCPTools os command injection

A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-agno-agi
Product-agno
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-7464
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-44.90% / 97.51%
||
7 Day CHG~0.00%
Published-05 Aug, 2024 | 01:00
Updated-15 Aug, 2024 | 13:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CP900 Telnet Service setTelnetCfg command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK CP900 6.3c.566. This issue affects the function setTelnetCfg of the component Telnet Service. The manipulation of the argument telnet_enabled leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273557 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-cp900cp900_firmwareCP900cp900
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8130
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.56% / 81.20%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 16:31
Updated-27 Aug, 2024 | 15:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request s3.cgi cgi_s3 command injection

A vulnerability has been found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814 and classified as critical. Affected by this vulnerability is the function cgi_s3 of the file /cgi-bin/s3.cgi of the component HTTP POST Request Handler. The manipulation of the argument f_a_key leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-340ldnr-202ldns-1550-04dns-327ldns-320lwdns-320ldns-323dns-1200-05dns-325dns-120dns-343dns-1100-4dns-320dnr-326dns-726-4dns-345dns-315ldnr-322ldns-326dns-321
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8127
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.38% / 84.72%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 09:31
Updated-27 Aug, 2024 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request webfile_mgr.cgi cgi_unzip command injection

A vulnerability classified as critical was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. This vulnerability affects the function cgi_unzip of the file /cgi-bin/webfile_mgr.cgi of the component HTTP POST Request Handler. The manipulation of the argument path leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-343_firmwarednr-202l_firmwaredns-320lw_firmwaredns-323_firmwaredns-320_firmwaredns-315l_firmwaredns-321_firmwaredns-320l_firmwarednr-322l_firmwaredns-325_firmwaredns-120_firmwaredns-326_firmwaredns-1550-04_firmwaredns-1200-05_firmwaredns-340l_firmwaredns-726-4_firmwaredns-345_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-7442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.57% / 68.06%
||
7 Day CHG~0.00%
Published-03 Aug, 2024 | 18:00
Updated-06 Aug, 2024 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Vivotek SD9364 upload_file.cgi getenv command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

Action-Not Available
Vendor-vivotekVivotek
Product-sd9364_firmwaresd9364SD9364
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8134
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.56% / 81.20%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 20:00
Updated-27 Aug, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request hd_config.cgi cgi_FMT_Std2R5_1st_DiskMGR command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been rated as critical. This issue affects the function cgi_FMT_Std2R5_1st_DiskMGR of the file /cgi-bin/hd_config.cgi of the component HTTP POST Request Handler. The manipulation of the argument f_source_dev leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8128
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.07% / 86.50%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 11:31
Updated-27 Aug, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request webfile_mgr.cgi cgi_add_zip command injection

A vulnerability, which was classified as critical, has been found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. This issue affects the function cgi_add_zip of the file /cgi-bin/webfile_mgr.cgi of the component HTTP POST Request Handler. The manipulation of the argument path leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-8129
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-16.75% / 94.80%
||
7 Day CHG~0.00%
Published-24 Aug, 2024 | 15:31
Updated-27 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 HTTP POST Request s3.cgi cgi_s3_modify command injection

A vulnerability, which was classified as critical, was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. Affected is the function cgi_s3_modify of the file /cgi-bin/s3.cgi of the component HTTP POST Request Handler. The manipulation of the argument f_job_name leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-327ldns-320lw_firmwaredns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.17%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 13:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formSetWanStatic os command injection

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.62% / 69.81%
||
7 Day CHG+0.26%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7525
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.61% / 81.50%
||
7 Day CHG+0.67%
Published-13 Jul, 2025 | 09:32
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setTracerouteCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been declared as critical. This vulnerability affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument command leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7083
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.17%
||
7 Day CHG-0.03%
Published-06 Jul, 2025 | 15:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs mp os command injection

A vulnerability was found in Belkin F9K1122 1.00.33. It has been classified as critical. This affects the function mp of the file /goform/mp of the component webs. The manipulation of the argument command leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7524
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.61% / 81.50%
||
7 Day CHG+0.67%
Published-13 Jul, 2025 | 09:02
Updated-15 Jul, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi setDiagnosisCfg command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748_B20211015. It has been classified as critical. This affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-t6_firmwaret6T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7613
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 76.15%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 14:44
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi CloudSrvVersionCheck command injection

A vulnerability was found in TOTOLINK T6 4.1.5cu.748. It has been rated as critical. This issue affects the function CloudSrvVersionCheck of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.12% / 31.40%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6620
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.26% / 84.37%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE upgrade.so setUpgradeUboot os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been rated as critical. Affected by this issue is the function setUpgradeUboot of the file upgrade.so. The manipulation of the argument FileName leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6621
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.26% / 84.37%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE ap.so QuickSetting os command injection

A vulnerability classified as critical has been found in TOTOLINK CA300-PoE 6.2c.884. This affects the function QuickSetting of the file ap.so. The manipulation of the argument hour/minute leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.30%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5836
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.80% / 82.53%
||
7 Day CHG+0.15%
Published-07 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5515
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.71% / 82.06%
||
7 Day CHG-0.03%
Published-03 Jun, 2025 | 17:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formMapDel command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X2000R 1.0.0-B20230726.1108. Affected by this issue is some unknown functionality of the file /boafrm/formMapDel. The manipulation of the argument devicemac1 leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.61% / 69.24%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5606
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.33% / 79.68%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 19:00
Updated-10 Jun, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5502
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.18% / 88.48%
||
7 Day CHG-0.05%
Published-03 Jun, 2025 | 14:00
Updated-06 Jun, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 formMapReboot command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x15x15_firmwareX15
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5492
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 35.78%
||
7 Day CHG+0.02%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.51% / 65.98%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5504
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.85% / 82.75%
||
7 Day CHG-0.04%
Published-03 Jun, 2025 | 14:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formWsc command injection

A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5438
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.79% / 82.47%
||
7 Day CHG+0.22%
Published-02 Jun, 2025 | 09:00
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 WPS command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. Affected by this vulnerability is the function WPS of the file /goform/WPS. The manipulation of the argument PIN leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5444
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.30%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5441
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.36%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')