ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC use non-random default credentials across all devices. A remote attacker can take complete control of a device using default admin credentials.
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC have a web application that uses the GET method to process requests that contain sensitive information such as user account name and password, which can expose that information through the browser's history, referrers, web logs, and other sources.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access.
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DaoService service, which listens on TCP port 9074 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26158.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the StorageNode service, which listens on TCP port 9075 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26156.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for root stored in the component /etc/shadow.sample.
A hardcoded credential vulnerability exists in IBM Merge Healthcare eFilm Workstation. A remote, unauthenticated attacker can exploit this vulnerability to achieve information disclosure or remote code execution.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for the telnet service stored in the component /web_cste/cgi-bin/product.ini.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
Trend Micro Apex One (2019), OfficeScan XG and Worry-Free Business Security (9.0, 9.5, 10.0) server contains a vulnerable service DLL file that could allow a remote attacker to execute arbitrary code on affected installations with SYSTEM level privileges. Authentication is not required to exploit this vulnerability.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device.
Veeam Backup & Replication 10.x and 11.x has Incorrect Access Control (issue 1 of 2).
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
The Invoker Servlet on SAP NetWeaver Application Server Java platforms, possibly before 7.3, does not require authentication, which allows remote attackers to execute arbitrary code via an HTTP or HTTPS request, as exploited in the wild in 2013 through 2016, aka a "Detour" attack.
The Intellian Aptus application 1.0.2 for Android has a hardcoded password of intellian for the masteruser FTP account.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution.
SAP Commerce, versions - 6.7, 1808, 1811, 1905, and SAP Commerce (Data Hub), versions - 6.7, 1808, 1811, 1905, allows an attacker to bypass the authentication and/or authorization that has been configured by the system administrator due to the use of Hardcoded Credentials.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
A remote unauthenticated arbitrary code execution vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
In IOBit IOTransfer 4.3.1.1561, an unauthenticated attacker can send GET and POST requests to Airserv and gain arbitrary read/write access to the entire file-system (with admin privileges) on the victim's endpoint, which can result in data theft and remote code execution.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
SAP NetWeaver AS JAVA (LM Configuration Wizard), versions - 7.30, 7.31, 7.40, 7.50, does not perform an authentication check which allows an attacker without prior authentication to execute configuration tasks to perform critical actions against the SAP Java system, including the ability to create an administrative user, and therefore compromising Confidentiality, Integrity and Availability of the system, leading to Missing Authentication Check.
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
SAP Solution Manager (Diagnostics Agent), version 720, allows unencrypted connections from unauthenticated sources. This allows an attacker to control all remote functions on the Agent due to Missing Authentication Check.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.