IBM Cloud Automation Manager 3.2.1.0 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site the user goes to. The cookie will be sent to the insecure link and the attacker can then obtain the cookie value by snooping the traffic. IBM X-Force ID: 168644.
evolution-data-server3 3.0.3 through 3.2.1 used insecure (non-SSL) connection when attempting to store sent email messages into the Sent folder, when the Sent folder was located on the remote server. An attacker could use this flaw to obtain login credentials of the victim.
The encrypt/decrypt functions in Ruby on Rails 2.3 are vulnerable to padding oracle attacks.
Privilege Escalation vulnerability in Microsoft Windows client (McTray.exe) in McAfee VirusScan Enterprise (VSE) 8.8 prior to Patch 13 allows local users to spawn unrelated processes with elevated privileges via the system administrator granting McTray.exe elevated privileges (by default it runs with the current user's privileges).
IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 could allow a remote attacker to obtain sensitive information, caused by the failure to properly enable HTTP Strict Transport Security. An attacker could exploit this vulnerability to obtain sensitive information using man in the middle techniques.
An issue existed with Siri Suggestions access to encrypted data. The issue was fixed by limiting access to encrypted data. This issue is fixed in macOS Catalina 10.15.3, Security Update 2020-001 Mojave, Security Update 2020-001 High Sierra. Encrypted data may be inappropriately accessed.
FusionSphere OpenStack with software V100R006C00SPC102(NFV) and V100R006C10 have an information leak vulnerability. Due to an incorrect configuration item, the information transmitted by a transmission channel is not encrypted. An attacker accessing the internal network may obtain sensitive information transmitted.
Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
An issue was discovered on ABUS Secvest wireless alarm system FUAA50000 3.01.01 in conjunction with Secvest remote control FUBE50014 or FUBE50015. Because "encrypted signal transmission" is missing, an attacker is able to eavesdrop sensitive data as cleartext (for instance, the current rolling code state).
Dell Data Lakehouse, version(s) 1.0.0.0, contain(s) a Missing Encryption of Sensitive Data vulnerability in the DDAE (Starburst). A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure.