Vulnerability Details :

CVE-2017-6028

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-30 Jun, 2017 | 02:35
Updated At-05 Aug, 2024 | 15:18
Rejected At-
Credits

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:30 Jun, 2017 | 02:35
Updated At:05 Aug, 2024 | 15:18
Rejected At:
▼CVE Numbering Authority (CNA)

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

Affected Products
Vendor
n/a
Product
Schneider Electric Modicon PLCs
Versions
Affected
  • Schneider Electric Modicon PLCs
Problem Types
TypeCWE IDDescription
CWECWE-522CWE-522
Type: CWE
CWE ID: CWE-522
Description: CWE-522
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
x_refsource_MISC
http://www.securityfocus.com/bid/97254
vdb-entry
x_refsource_BID
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
Resource:
x_refsource_MISC
Hyperlink: http://www.securityfocus.com/bid/97254
Resource:
vdb-entry
x_refsource_BID
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
x_refsource_MISC
x_transferred
http://www.securityfocus.com/bid/97254
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
Resource:
x_refsource_MISC
x_transferred
Hyperlink: http://www.securityfocus.com/bid/97254
Resource:
vdb-entry
x_refsource_BID
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:30 Jun, 2017 | 03:29
Updated At:13 May, 2026 | 00:24

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>modicon_m241_firmware>>Versions up to 4.0.3.20(inclusive)
cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m241>>-
cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m251_firmware>>Versions up to 4.0.3.20(inclusive)
cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>modicon_m251>>-
cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-522Secondaryics-cert@hq.dhs.gov
CWE-522Primarynvd@nist.gov
CWE ID: CWE-522
Type: Secondary
Source: ics-cert@hq.dhs.gov
CWE ID: CWE-522
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://www.securityfocus.com/bid/97254ics-cert@hq.dhs.gov
Third Party Advisory
VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
http://www.securityfocus.com/bid/97254af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
US Government Resource
Hyperlink: http://www.securityfocus.com/bid/97254
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource
Hyperlink: http://www.securityfocus.com/bid/97254
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

477Records found

CVE-2022-32520
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 59.81%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-22798
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.29% / 52.81%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)

Action-Not Available
Vendor-n/a
Product-conext_comboxconext_combox_firmwareConext� ComBox (All Versions)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2015-3962
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.26% / 50.12%
||
7 Day CHG~0.00%
Published-18 Sep, 2015 | 22:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-struxureware_building_expert_multi-purpose_managementn/a
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2018-7820
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.28% / 51.90%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:45
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.

Action-Not Available
Vendor-
Product-ap9630ap9631ap9635smart-ups_srt_5kvaap9635_firmwareap9630_firmwaresmart-ups_srt_5kva_firmwareap9631_firmwareAPC UPS Network Management Card 2 AOS
CWE ID-CWE-255
Not Available
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32519
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 59.81%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-32518
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-8||HIGH
EPSS-0.38% / 59.81%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-data_center_expertData Center Expert
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-0223
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.57% / 68.87%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-29411
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.71% / 92.09%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:49
Updated-05 Feb, 2025 | 21:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow changes to administrative credentials, leading to potential remote code execution without requiring prior authentication on the Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2023-29412
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.54% / 85.75%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:50
Updated-05 Feb, 2025 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-28004
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.28% / 79.97%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 21:16
Updated-02 Aug, 2024 | 12:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution.

Action-Not Available
Vendor-
Product-powerlogic_hdpm6000_firmwarepowerlogic_hdpm6000PowerLogic HDPM6000
CWE ID-CWE-129
Improper Validation of Array Index
CVE-2023-25550
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.75% / 82.94%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:36
Updated-12 Feb, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-6806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.42% / 62.55%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:04
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CVE-2019-6850
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 55.64%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:54
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6840
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.50% / 66.53%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:19
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Format String: CWE-134 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to send a crafted message to the target server, thereby causing arbitrary commands to be executed.

Action-Not Available
Vendor-
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0002meg6501-0001_firmwaremeg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Server
CWE ID-CWE-134
Use of Externally-Controlled Format String
CVE-2019-6814
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-66.93% / 98.57%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:38
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.

Action-Not Available
Vendor-n/a
Product-net5504_firmwarenet5500_firmwarenet5501-inet5508net5516_firmwarenet5508_firmwarenet5516net5501_firmwarenet5504net5501-xt_firmwarenet5501-xtnet5500net5501-i_firmwarenet5501ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê
CWE ID-CWE-287
Improper Authentication
CVE-2019-6808
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-4.31% / 89.10%
||
7 Day CHG+1.98%
Published-22 May, 2019 | 20:05
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2019-6851
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-2.47% / 85.56%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:55
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6849
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 55.64%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:53
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6824
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-8.87% / 92.72%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:44
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-6859
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 57.29%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-n/a
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-22768
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.79% / 74.25%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-29 May, 2026 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-powerlogic_egx300_firmwarepowerlogic_egx100_firmwarepowerlogic_egx100powerlogic_egx300PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions)
CWE ID-CWE-20
Improper Input Validation
CVE-2012-0931
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.15% / 88.89%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-287
Improper Authentication
CVE-2018-7232
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 78.80%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 00:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-20
Improper Input Validation
CVE-2018-7837
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.31% / 54.23%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Restriction of XML External Entity Reference ('XXE') vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow the software to resolve documents outside of the intended sphere of control, causing the software to embed incorrect documents into its output and expose restricted information.

Action-Not Available
Vendor-
Product-iiot_moniorIIoT Monitor 3.1.38
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2018-7847
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.77% / 73.92%
||
7 Day CHG+0.44%
Published-22 May, 2019 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CWE ID-CWE-287
Improper Authentication
CVE-2011-4036
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-5||MEDIUM
EPSS-0.51% / 66.62%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-citecthistorianvijeo_historiancitectscada_reportsn/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-7244
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.21% / 43.78%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.

Action-Not Available
Vendor-
Product-mge_galaxy_4000mge_galaxy_5000mge_eps_8000mge_galaxy_pwmge_galaxy_300066074_mge_network_management_card_transversemge_comet_upsmge_eps_6000mge_galaxy_6000mge_galaxy_9000mge_eps_700066074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-25549
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-1.75% / 82.94%
||
7 Day CHG~0.00%
Published-18 Apr, 2023 | 20:35
Updated-03 Mar, 2025 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)

Action-Not Available
Vendor-Schneider Electric SE
Product-struxureware_data_center_expertStruxureWare Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2015-6485
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.32% / 55.75%
||
7 Day CHG~0.00%
Published-12 Mar, 2016 | 02:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-sage_2300sage_1410sage_landac_ii-2telvent_rtu_firmwaresage_2400sage_1430sage_1450sage_3030mn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-45788
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.40% / 60.75%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-29 May, 2026 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m340_bmxp342030_firmwaremodicon_premium_tsxp57_454mmodicon_m340_bmxp3420302h_firmwaremodicon_premium_tsxp57_2834m_firmwaremodicon_premium_tsxp57_6634m_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_quantum_140cpu65160_firmwaremodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_mc80_bmkc8020310_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_premium_tsxp57_454m_firmwaremodicon_quantum_140cpu65150modicon_m580_bmep584040_firmwaremodicon_momentum_171cbu78090_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep585040modicon_premium_tsxp57_4634mmodicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040c_firmwaremodicon_premium_tsxp57_2634m_firmwaremodicon_m580_bmeh584040_firmwaremodicon_momentum_171cbu78090modicon_premium_tsxp57_5634mmodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_mc80_bmkc8020301modicon_m580_bmeh584040s_firmwaremodicon_momentum_171cbu98090_firmwaremodicon_m580_bmep582040smodicon_premium_tsxp57_1634m_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmeh586040cmodicon_m580_bmep582020_firmwaremodicon_momentum_171cbu98091modicon_m340_bmxp342000_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh586040_firmwaremodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmeh582040_firmwaremodicon_quantum_140cpu65150c_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_quantum_140cpu65160c_firmwaremodicon_mc80_bmkc8030311modicon_quantum_140cpu65160modicon_momentum_171cbu98090modicon_premium_tsxp57_1634mmodicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_premium_tsxp57_2634mmodicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep583020_firmwaremodicon_premium_tsxp57_5634m_firmwaremodicon_premium_tsxp57_554m_firmwaremodicon_m340_bmxp341000modicon_mc80_bmkc8020310modicon_m580_bmep582020modicon_quantum_140cpu65160cmodicon_m580_bmeh584040c_firmwaremodicon_quantum_140cpu65150_firmwaremodicon_momentum_171cbu98091_firmwaremodicon_quantum_140cpu65150cmodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_mc80_bmkc8030311_firmwaremodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_premium_tsxp57_554mmodicon_m580_bmep582040s_firmwaremodicon_premium_tsxp57_2834mmodicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwaremodicon_mc80_bmkc8020301_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_premium_tsxp57_4634m_firmwaremodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwaremodicon_premium_tsxp57_6634mLegacy Modicon Quantum (140CPU65*) and Premium CPUs (TSXP57*)Modicon M580 CPU (part numbers BMEP* and BMEH*) Modicon M340 CPU (part numbers BMXP34*)Modicon MC80 (BMKC80)EcoStruxure Control Expert Modicon Momentum Unity M1E Processor (171CBU*)Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)EcoStruxure Process Expert
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2022-42970
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.66% / 71.51%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)

Action-Not Available
Vendor-Microsoft CorporationSchneider Electric SE
Product-windows_server_2016apc_easy_ups_online_monitoring_softwareeasy_ups_online_monitoring_softwarewindows_7windows_11windows_10windows_server_2022windows_server_2019Schneider Electric Easy UPS Online Monitoring SoftwareAPC Easy UPS Online Monitoring Software
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 60.57%
||
7 Day CHG~0.00%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-37300
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.57% / 69.06%
||
7 Day CHG~0.00%
Published-12 Sep, 2022 | 17:40
Updated-03 Aug, 2024 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).

Action-Not Available
Vendor-
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302h_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmeh584040modicon_m580_bmep585040modicon_m580_bmep585040c_firmwaremodicon_m580_bmeh584040_firmwaremodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m340_bmxp342020modicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmeh586040cmodicon_m580_bmep582020_firmwaremodicon_m340_bmxp342000_firmwaremodicon_m580_bmeh586040_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmeh582040_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp341000modicon_m580_bmeh584040c_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwareEcoStruxure Control ExpertEcoStruxure Process ExpertModicon M340 CPUModicon M580 CPU
CWE ID-CWE-640
Weak Password Recovery Mechanism for Forgotten Password
CVE-2022-34756
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.87% / 83.48%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:10
Updated-17 Sep, 2024 | 04:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior)

Action-Not Available
Vendor-
Product-easergy_p5_firmwareeasergy_p5Easergy P5
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-46680
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.16% / 36.71%
||
7 Day CHG+0.02%
Published-22 May, 2023 | 13:25
Updated-21 Jan, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic.

Action-Not Available
Vendor-Schneider Electric SE
Product-powerlogic_ion8650powerlogic_ion9000_firmwarepowerlogic_ion9000powerlogic_pm8000powerlogic_pm8000_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion8800_firmwarepowerlogic_ion8800powerlogic_ion7400powerlogic_ion8650_firmwarePowerLogic ION9000PowerLogic ION8800Legacy ION products PowerLogic PM8000PowerLogic ION7400PowerLogic ION8650
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2022-32526
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.60% / 85.93%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32524
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.03%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32529
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.03%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32513
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.48% / 65.46%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-521
Weak Password Requirements
CVE-2022-32525
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.60% / 85.93%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32523
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.77% / 83.03%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-32514
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.46% / 64.51%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)

Action-Not Available
Vendor-Schneider Electric SE
Product-5500ac2_firmware5500shaclss5500nac5500ac2lss5500shaclss5500nac_firmwarelss5500shac_firmware5500nac_firmware5500nac5500nac25500shac_firmware5500nac2_firmwareClipsal C-Bus Network Automation Controller, 5500NACSpaceLogic C-Bus Network Automation Controller, 5500NAC2Clipsal Wiser for C-Bus Automation Controller, 5500SHACWiser for C-Bus Automation Controller, LSS5500SHACSpaceLogic C-Bus Application Controller, 5500AC2C-Bus Network Automation Controller, LSS5500NAC
CWE ID-CWE-287
Improper Authentication
CVE-2022-45789
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.1||HIGH
EPSS-0.12% / 29.91%
||
7 Day CHG+0.05%
Published-31 Jan, 2023 | 00:00
Updated-29 May, 2026 | 14:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)

Action-Not Available
Vendor-Schneider Electric SE
Product-modicon_m340_bmxp342030_firmwaremodicon_m340_bmxp3420302h_firmwaremodicon_m340_bmxp342020h_firmwaremodicon_m580_bmep583040_firmwaremodicon_m580_bmeh582040smodicon_m340_bmxp3420302_firmwaremodicon_m340_bmxp342010modicon_m580_bmeh584040smodicon_m580_bmep582020h_firmwaremodicon_m580_bmep584040s_firmwaremodicon_m580_bmep584040modicon_m340_bmxp342010_firmwaremodicon_m340_bmxp342020_firmwaremodicon_m340_bmxp3420102_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep582040h_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040ecostruxure_control_expertmodicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmep585040modicon_m580_bmep585040c_firmwaremodicon_m580_bmeh584040modicon_m580_bmeh584040_firmwaremodicon_m580_bmep581020h_firmwaremodicon_m580_bmep584020modicon_m580_bmeh584040s_firmwaremodicon_m340_bmxp342020modicon_m580_bmep582040smodicon_m340_bmxp342030hmodicon_m340_bmxp342020hmodicon_m580_bmep582020_firmwaremodicon_m580_bmeh586040cmodicon_m340_bmxp342000_firmwaremodicon_m580_bmep581020hmodicon_m580_bmeh586040_firmwaremodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_m580_bmeh586040c_firmwaremodicon_m580_bmeh582040_firmwaremodicon_m580_bmep586040_firmwaremodicon_m580_bmep582040_firmwaremodicon_m580_bmeh582040modicon_m580_bmeh582040c_firmwaremodicon_m580_bmep583020modicon_m580_bmeh586040s_firmwaremodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_m340_bmxp342000modicon_m580_bmeh586040modicon_m580_bmep582020modicon_m580_bmep583020_firmwaremodicon_m340_bmxp341000modicon_m580_bmeh584040c_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep582040hmodicon_m340_bmxp3420302modicon_m580_bmep582040s_firmwaremodicon_m340_bmxp341000_firmwaremodicon_m580_bmep581020_firmwareecostruxure_process_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m340_bmxp342030h_firmwaremodicon_m580_bmep582020hmodicon_m580_bmep586040c_firmwaremodicon_m340_bmxp3420102modicon_m580_bmeh582040s_firmwareModicon M580 CPU (part numbers BMEP* and BMEH*) Modicon M340 CPU (part numbers BMXP34*)EcoStruxure Control Expert Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)EcoStruxure Process Expert
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2022-30234
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.4||CRITICAL
EPSS-0.37% / 58.88%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 19:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2022-30235
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.27% / 50.75%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 17:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2022-24311
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-3.70% / 88.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2022-24324
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.43% / 85.46%
||
7 Day CHG~0.00%
Published-01 Feb, 2023 | 00:00
Updated-05 Feb, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073)

Action-Not Available
Vendor-Schneider Electric SE
Product-interactive_graphical_scada_systemIGSS Data Server (IGSSdataServer.exe)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24313
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-7.77% / 92.12%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2022-24310
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-1.98% / 83.91%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:04
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_serverInteractive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CWE ID-CWE-190
Integer Overflow or Wraparound
CVE-2022-24318
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.08% / 23.84%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 22:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Action-Not Available
Vendor-n/a
Product-clearscadaecostruxure_geo_scada_expert_2020ecostruxure_geo_scada_expert_2019ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CWE ID-CWE-326
Inadequate Encryption Strength
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 9
  • 10
  • Next
Details not found