A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12959)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13402)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13430)
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13059)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13194)
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13423)
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13060)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13023
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13342)
An out-of-bounds write issue exists in the DWG file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15054)
An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)
A use-after-free issue exists in the DGN file-reading procedure in the Drawings SDK (All versions prior to 2022.4) resulting from the lack of proper validation of user-supplied data. This can result in a memory corruption or arbitrary code execution, allowing attackers to cause a denial-of-service condition or execute code in the context of the current process.
An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-046)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-039)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-045)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-041)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-051)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-044)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-054)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-042)
A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114)
A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of SGI and RGB files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11992)
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2022.1). The starview+.exe contains a memory corruption vulnerability while parsing specially crafted .SCE files. This could allow an attacker to execute code in the context of the current process.
The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request.
The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF.
Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
storeAtts in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131)
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing CATPart files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing PRT files. This could lead to pointer dereferences of a value obtained from an untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819)
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)