Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2018-10713

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-03 May, 2018 | 16:00
Updated At-16 Sep, 2024 | 18:43
Rejected At-
Credits

An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'read' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'read <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:03 May, 2018 | 16:00
Updated At:16 Sep, 2024 | 18:43
Rejected At:
▼CVE Numbering Authority (CNA)

An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'read' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'read <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/kgsdy/D-Link-DSL-3782-EU
x_refsource_MISC
Hyperlink: https://github.com/kgsdy/D-Link-DSL-3782-EU
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/kgsdy/D-Link-DSL-3782-EU
x_refsource_MISC
x_transferred
Hyperlink: https://github.com/kgsdy/D-Link-DSL-3782-EU
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:03 May, 2018 | 16:29
Updated At:26 Apr, 2023 | 18:55

An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'read' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'read <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

D-Link Corporation
d-link
>>dsl-3782_firmware>>1.01
cpe:2.3:o:d-link:dsl-3782_firmware:1.01:*:*:*:*:*:*:*
D-Link Corporation
dlink
>>dsl-3782>>-
cpe:2.3:h:dlink:dsl-3782:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarynvd@nist.gov
CWE ID: CWE-119
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/kgsdy/D-Link-DSL-3782-EUcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://github.com/kgsdy/D-Link-DSL-3782-EU
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

417Records found

CVE-2019-15529
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.53% / 93.68%
||
7 Day CHG~0.00%
Published-23 Aug, 2019 | 16:03
Updated-05 Aug, 2024 | 00:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-823G devices with firmware V1.0.2B05. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the Username field to Login.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823gdir-823g_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8956
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 26.27%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7922
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 80.82%
||
7 Day CHG~0.00%
Published-19 Aug, 2024 | 15:00
Updated-20 Aug, 2024 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 myMusic.cgi cgi_write_playlist command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814 and classified as critical. Affected by this issue is the function cgi_audio_search/cgi_create_playlist/cgi_get_album_all_tracks/cgi_get_alltracks_editlist/cgi_get_artist_all_album/cgi_get_genre_all_tracks/cgi_get_tracks_list/cgi_set_airplay_content/cgi_write_playlist of the file /cgi-bin/myMusic.cgi. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link CorporationDell Inc.
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-120_firmwaredns-326_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-343_firmwarednr-202l_firmwaredns-320lw_firmwaredns-323_firmwaredns-320_firmwaredns-315l_firmwaredns-321_firmwaredns-320l_firmwarednr-322l_firmwaredns-325_firmwaredns-120_firmwaredns-326_firmwaredns-1550-04_firmwaredns-726-4_firmwaredns-1200-05_firmwaredns-340l_firmwaredns-1100-4_firmwarednr-326_firmwaredns-345_firmwaredns-327l_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-32168
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-1.36% / 79.39%
||
7 Day CHG+0.09%
Published-03 May, 2024 | 01:56
Updated-07 Aug, 2025 | 15:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View showUser Improper Authorization Privilege Escalation Vulnerability

D-Link D-View showUser Improper Authorization Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of D-Link D-View. Authentication is required to exploit this vulnerability. The specific flaw exists within the showUser method. The issue results from the lack of proper authorization before accessing a privileged endpoint. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. . Was ZDI-CAN-19534.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-Viewd-view
CWE ID-CWE-285
Improper Authorization
CVE-2023-5150
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.28% / 50.72%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:31
Updated-18 Jun, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 web.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000 and DAR-8000 up to 20151231. Affected is an unknown function of the file /useratte/web.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-240246 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-8000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-7715
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.02%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 06:31
Updated-15 Aug, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 photocenter_mgr.cgi sprintf command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240812. It has been classified as critical. This affects the function sprintf of the file /cgi-bin/photocenter_mgr.cgi. The manipulation of the argument filter leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-DNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-120_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7831
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.56% / 80.75%
||
7 Day CHG~0.00%
Published-15 Aug, 2024 | 13:00
Updated-19 Aug, 2024 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 photocenter_mgr.cgi cgi_get_cooliris buffer overflow

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814 and classified as critical. Affected by this vulnerability is the function cgi_get_cooliris of the file /cgi-bin/photocenter_mgr.cgi. The manipulation of the argument path leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-120_firmwaredns-326_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-340ldnr-202ldns-1550-04dns-327ldns-320lwdns-320ldns-323dns-1200-05dns-325dns-120dns-343dns-1100-4dns-320dnr-326dns-726-4dns-345dns-315ldnr-322ldns-326dns-321
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-6896
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.84%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 07:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ wget_test.asp os command injection

A vulnerability classified as critical has been found in D-Link DI-7300G+ 19.12.25A1. Affected is an unknown function of the file wget_test.asp. The manipulation of the argument url leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6899
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.04%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:32
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+/DI-8200G msp_info.htm os command injection

A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-8200gdi-8200g_firmwaredi-7300g\+DI-8200GDI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7192
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.84%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 19:32
Updated-14 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-645 ssdpcgi cgibin ssdpcgi_main command injection

A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-645_firmwaredir-645DIR-645
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6898
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.23%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-5146
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.88% / 74.47%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 00:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 updatelib.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231 and classified as critical. Affected by this issue is some unknown functionality of the file /sysmanage/updatelib.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-240242 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-5371
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.05% / 76.66%
||
7 Day CHG~0.00%
Published-12 Jan, 2018 | 09:00
Updated-05 Aug, 2024 | 05:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

diag_ping.cmd on D-Link DSL-2640U devices with firmware IM_1.00 and ME_1.00, and DSL-2540U devices with firmware ME_1.00, allows authenticated remote attackers to execute arbitrary OS commands via shell metacharacters in the ipaddr field of an HTTP GET request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-2540u_firmwaredsl-2640u_firmwaredsl-2540udsl-2640un/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-5148
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.08% / 83.26%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:00
Updated-24 Sep, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 uploadfile.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231. It has been declared as critical. This vulnerability affects unknown code of the file /Tool/uploadfile.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240244. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000dar-8000_firmwaredar-7000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2025-5571
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.21%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-5149
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.41% / 60.59%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 userattestation.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2025-5573
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.73%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5492
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 15.80%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-20674
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.10%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 00:00
Updated-16 Sep, 2024 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-822 C1 before v3.11B01Beta, DIR-822-US C1 before v3.11B01Beta, DIR-850L A* before v1.21B08Beta, DIR-850L B* before v2.22B03Beta, and DIR-880L A* before v1.20B02Beta devices allow authenticated remote command execution.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-822-usdir-850ldir-880ldir-850l_firmwaredir-822_firmwaredir-880l_firmwaredir-822dir-822-us_firmwaren/a
CVE-2019-13128
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-12.53% / 93.68%
||
7 Day CHG~0.00%
Published-01 Jul, 2019 | 14:47
Updated-04 Aug, 2024 | 23:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-823G devices with firmware 1.02B03. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the IPAddress or Gateway field to SetStaticRouteSettings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823gdir-823g_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-20057
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-25.02% / 95.95%
||
7 Day CHG~0.00%
Published-11 Dec, 2018 | 09:00
Updated-05 Aug, 2024 | 11:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in /bin/boa on D-Link DIR-619L Rev.B 2.06B1 and DIR-605L Rev.B 2.12B1 devices. goform/formSysCmd allows remote authenticated users to execute arbitrary OS commands via the sysCmd POST parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-619ldir-605l_firmwaredir-605ldir-619l_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-17990
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.27% / 83.97%
||
7 Day CHG~0.00%
Published-01 Apr, 2019 | 20:53
Updated-05 Aug, 2024 | 11:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DSL-3782 devices with firmware 1.01. An OS command injection vulnerability in Acl.asp allows a remote authenticated attacker to execute arbitrary OS commands via the ScrIPaddrEndTXT parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-3782_firmwaredsl-3782n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-20694
Matching Score-8
Assigner-JPCERT/CC
ShareView Details
Matching Score-8
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.20% / 42.63%
||
7 Day CHG~0.00%
Published-26 Apr, 2021 | 00:20
Updated-03 Aug, 2024 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper access control vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to bypass access restriction and to start a telnet service via unspecified vectors.

Action-Not Available
Vendor-D-Link Corporation
Product-dap-1880acdap-1880ac_firmwareDAP-1880AC
CVE-2018-17442
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.01% / 91.09%
||
7 Day CHG~0.00%
Published-08 Oct, 2018 | 16:00
Updated-05 Aug, 2024 | 10:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link Central WiFi Manager before v 1.03r0100-Beta1. An unrestricted file upload vulnerability in the onUploadLogPic endpoint allows remote authenticated users to execute arbitrary PHP code.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-central_wifimanagern/a
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2019-12787
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.49% / 84.70%
||
7 Day CHG-0.35%
Published-10 Jun, 2019 | 17:49
Updated-04 Aug, 2024 | 23:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-818LW devices from 2.05.B03 to 2.06B01 BETA. There is a command injection in HNAP1 SetWanSettings via an XML injection of the value of the Gateway key.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-818lw_firmwaredir-818lwn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4454
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-5299
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-4.55% / 88.75%
||
7 Day CHG+1.13%
Published-23 May, 2024 | 21:30
Updated-06 Aug, 2025 | 14:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View execMonitorScript Exposed Dangerous Method Remote Code Execution Vulnerability

D-Link D-View execMonitorScript Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the execMonitorScript method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21828.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-Viewd-view
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2025-4445
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 29.79%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4341
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 16.55%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:31
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-880L Request Header ssdpcgi sub_16570 command injection

A vulnerability classified as critical was found in D-Link DIR-880L up to 104WWb01. Affected by this vulnerability is the function sub_16570 of the file /htdocs/ssdpcgi of the component Request Header Handler. The manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-880l_firmwaredir-880lDIR-880L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-10431
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.38% / 86.87%
||
7 Day CHG~0.00%
Published-26 Apr, 2018 | 17:00
Updated-05 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-615 2.5.17 devices allow Remote Code Execution via shell metacharacters in the Host field of the System / Traceroute screen.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-615_firmwaredir-615n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-10967
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.80% / 85.55%
||
7 Day CHG~0.00%
Published-18 May, 2018 | 14:00
Updated-05 Aug, 2024 | 07:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On D-Link DIR-550A and DIR-604M devices through v2.10KR, a malicious user can forge an HTTP request to inject operating system commands that can be executed on the device with higher privileges, aka remote code execution.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-550a_firmwaredir-604mdir-550adir-604m_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-5298
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-4.55% / 88.75%
||
7 Day CHG+1.13%
Published-23 May, 2024 | 21:30
Updated-06 Aug, 2025 | 14:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability

D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D-View. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the queryDeviceCustomMonitorResult method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21842.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-Viewdir-3040_firmware
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2022-29778
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-25.24% / 95.98%
||
7 Day CHG~0.00%
Published-03 Jun, 2022 | 20:19
Updated-28 Oct, 2024 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-890L 1.20b01 allows attackers to execute arbitrary code due to the hardcoded option Wake-On-Lan for the parameter 'descriptor' at SetVirtualServerSettings.php

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-890l_firmwaredir-890ln/adir-890l_firmware
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-9122
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-9.63% / 92.58%
||
7 Day CHG~0.00%
Published-25 Feb, 2019 | 05:00
Updated-04 Aug, 2024 | 21:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the ntp_server parameter in an ntp_sync.cgi POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-825_rev.b_firmwaredir-825_rev.bn/a
CVE-2023-5143
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.45% / 62.55%
||
7 Day CHG~0.00%
Published-24 Sep, 2023 | 22:31
Updated-06 Mar, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 webmailattach.php Privilege Escalation

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000 up to 20151231. This issue affects some unknown processing of the file /log/webmailattach.php. The manipulation of the argument table_name leads to an unknown weakness. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240239. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000dar-7000_firmwareDAR-7000
CWE ID-CWE-20
Improper Input Validation
CVE-2023-5153
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.43% / 61.38%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 02:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 querysql.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-8000 up to 20151231. This affects an unknown part of the file /Tool/querysql.php. The manipulation leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240249 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-8000
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-44410
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-0.38% / 58.70%
||
7 Day CHG-0.01%
Published-03 May, 2024 | 02:13
Updated-07 Aug, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View showUsers Improper Authorization Privilege Escalation Vulnerability

D-Link D-View showUsers Improper Authorization Privilege Escalation Vulnerability. This vulnerability allows remote attackers to escalate privileges on affected installations of D-Link D-View. Authentication is required to exploit this vulnerability. The specific flaw exists within the showUsers method. The issue results from the lack of proper authorization before accessing a privileged endpoint. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the user. . Was ZDI-CAN-19535.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-Viewd-view
CWE ID-CWE-285
Improper Authorization
CVE-2025-1800
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.20%
||
7 Day CHG~0.00%
Published-01 Mar, 2025 | 18:00
Updated-21 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 HTTP POST Request sxh_vpnlic.php get_ip_addr_details command injection

A vulnerability has been found in D-Link DAR-7000 3.2 and classified as critical. This vulnerability affects the function get_ip_addr_details of the file /view/vpn/sxh_vpn/sxh_vpnlic.php of the component HTTP POST Request Handler. The manipulation of the argument ethname leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-9783
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.33% / 55.35%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 11:31
Updated-16 Oct, 2024 | 16:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formLogDnsquery buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formLogDnsquery of the file /goform/formLogDnsquery. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9915
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 42.45%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 18:31
Updated-16 Oct, 2024 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formVirtualServ buffer overflow

A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. Affected by this vulnerability is the function formVirtualServ of the file /goform/formVirtualServ. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9558
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.76% / 72.43%
||
7 Day CHG~0.00%
Published-06 Oct, 2024 | 18:00
Updated-08 Oct, 2024 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetWanPPTP buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formSetWanPPTP of the file /goform/formSetWanPPTP. The manipulation of the argument webpage leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9549
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.31%
||
7 Day CHG~0.00%
Published-06 Oct, 2024 | 04:00
Updated-10 Oct, 2024 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formEasySetupWizard formEasySetupWizard2 buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formEasySetupWizard/formEasySetupWizard2 of the file /goform/formEasySetupWizard. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9567
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.07%
||
7 Day CHG~0.00%
Published-07 Oct, 2024 | 13:31
Updated-09 Oct, 2024 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formAdvFirewall buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. This issue affects the function formAdvFirewall of the file /goform/formAdvFirewall. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9559
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.76% / 72.43%
||
7 Day CHG~0.00%
Published-06 Oct, 2024 | 18:31
Updated-08 Oct, 2024 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formWlanSetup buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been classified as critical. Affected is the function formWlanSetup of the file /goform/formWlanSetup. The manipulation of the argument webpage leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9568
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 47.78%
||
7 Day CHG~0.00%
Published-07 Oct, 2024 | 14:31
Updated-09 Oct, 2024 | 13:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formAdvNetwork buffer overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-619L B1 2.06. Affected is the function formAdvNetwork of the file /goform/formAdvNetwork. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9909
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.67% / 70.37%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 14:00
Updated-16 Oct, 2024 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetMuti buffer overflow

A vulnerability has been found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this vulnerability is the function formSetMuti of the file /goform/formSetMuti. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9786
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.58% / 67.79%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 13:00
Updated-16 Oct, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetLog buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. Affected by this issue is the function formSetLog of the file /goform/formSetLog. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 8
  • 9
  • Next
Details not found