A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14913)
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907)
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)
The jutil.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocation structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system.
A flaw was found in c-ares library, where a missing input validation check of host names returned by DNS (Domain Name Servers) can lead to output of wrong hostnames which might potentially lead to Domain Hijacking. The highest threat from this vulnerability is to confidentiality and integrity as well as system availability.
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13352)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13351)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12956)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13194)
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13380)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13442)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13060)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13403)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13196)
A use-after-free in Busybox 1.35-x's awk applet leads to denial of service and possibly code execution when processing a crafted awk pattern in the copyvar function.
Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.
A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier.
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a valid challenge-response pair generated by a legitimate user, and request the webpage repeatedly to wait for the same challenge to reappear for which the correct response is known. This could allow the attacker to access the management interface of the device.
An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.
The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.
An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6 on all supported by ODA platforms in static configuration. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution.
The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors.
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777)
json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend.
A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library is vulnerable to uninitialized pointer free while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13057)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13424)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13430)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13350)
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)
A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608)
An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart).
In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security.