A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The Application Server exposes directory listings and files containing sensitive information. This vulnerability is independent from CVE-2019-18287. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain remote code execution by sending specifically crafted objects via RMI. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18318. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.15 and below; Aruba Instant 8.3.x: 8.3.0.11 and below; Aruba Instant 8.4.x: 8.4.0.5 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18318 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. A remote attacker with network access to the CCS server could exploit this vulnerability to read the CCS users database, including the passwords of all users in obfuscated cleartext.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to enumerate running RPC services. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could be able to read and write arbitrary files on the local file system by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18321. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server can cause a Denial-of-Service condition by sending specifically crafted objects via RMI. This vulnerability is independent from CVE-2019-18317 and CVE-2019-18319. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could be able to upload arbitrary files without authentication. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (ephemeral-association demobilization) by sending a spoofed crypto-NAK packet with incorrect authentication data at a certain time.
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP.
A vulnerability has been identified in Siveillance Video Mobile Server V2022 R2 (All versions < V22.2a (80)). The mobile server component of affected applications improperly handles the log in for Active Directory accounts that are part of Administrators group. This could allow an unauthenticated remote attacker to access the application without a valid account.
A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
The Remote Console in IBM Lotus Domino, when a certain unsupported configuration involving UNC share pathnames is used, allows remote attackers to bypass authentication and execute arbitrary code via unspecified vectors, aka SPR PRAD89WGRS.
Intel Alert Management System (aka AMS or AMS2), as used in Symantec Antivirus Corporate Edition (SAVCE) 10.x before 10.1 MR10, Symantec System Center (SSC) 10.x, and Symantec Quarantine Server 3.5 and 3.6, allows remote attackers to execute arbitrary commands via crafted messages over TCP, as discovered by Junaid Bohio, a different vulnerability than CVE-2010-0110 and CVE-2010-0111. NOTE: some of these details are obtained from third party information.
The Update Installer in VMware ESXi 4.1, when a modified sfcb.cfg is present, does not properly configure the SFCB authentication mode, which allows remote attackers to obtain access via an arbitrary username and password.
Discuz! DiscuzX 3.4, when WeChat login is enabled, allows remote attackers to bypass authentication by leveraging a non-empty #wechat#common_member_wechatmp to gain login access to an account via a plugin.php ac=wxregister request (the attacker does not have control over which account will be accessed).
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
Improper handling of LDAP authentication in MongoDB Server versions 3.0.0 to 3.0.6 allows an unauthenticated client to gain unauthorized access.
The SSHv2 functionality in Cisco IOS 15.2, 15.3, 15.4, and 15.5 and IOS XE 3.6E before 3.6.3E, 3.7E before 3.7.1E, 3.10S before 3.10.6S, 3.11S before 3.11.4S, 3.12S before 3.12.3S, 3.13S before 3.13.3S, and 3.14S before 3.14.1S does not properly implement RSA authentication, which allows remote attackers to obtain login access by leveraging knowledge of a username and the associated public key, aka Bug ID CSCus73013.
The pam_lsass library in Likewise Open 5.4 and CIFS 5.4 before build 8046, and 6.0 before build 8234, as used in HP StorageWorks X9000 Network Storage Systems and possibly other products, uses "SetPassword logic" when running as part of a root service, which allows remote attackers to bypass authentication for a Likewise Security Authority (lsassd) account whose password is marked as expired.
IBM LoopBack (IBM API Connect 2018.1, 2018.4.1, 5.0.8.0, and 5.0.8.4) could allow an attacker to bypass authentication if the AccessToken Model is exposed over a REST API, it is then possible for anyone to create an AccessToken for any User provided they know the userId and can hence get access to the other user’s data / access to their privileges (if the user happens to be an Admin for example). IBM X-Force ID: 148801.
An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability.
The Horde_Ldap library before 2.0.6 for Horde allows remote attackers to bypass authentication by leveraging knowledge of the LDAP bind user DN.
The rsync daemon in F5 BIG-IP 11.6 before 11.6.0, 11.5.1 before HF3, 11.5.0 before HF4, 11.4.1 before HF4, 11.4.0 before HF7, 11.3.0 before HF9, and 11.2.1 before HF11 and Enterprise Manager 3.x before 3.1.1 HF2, when configured in failover mode, does not require authentication, which allows remote attackers to read or write to arbitrary files via a cmi request to the ConfigSync IP address.
The base-files package before 5.0.0ubuntu7.1 on Ubuntu 9.10 and before 5.0.0ubuntu20.10.04.2 on Ubuntu 10.04 LTS, as shipped on Dell Latitude 2110 netbooks, does not require authentication for package installation, which allows remote archive servers and man-in-the-middle attackers to execute arbitrary code via a crafted package.
BigTree 4.2.23 on Windows, when Advanced or Simple Rewrite routing is enabled, allows remote attackers to bypass authentication via a ..\ substring, as demonstrated by a launch.php?bigtree_htaccess_url=admin/images/..\ URI.
IBM API Connect 5.0.0.0-5.0.8.3 Developer Portal does not enforce Two Factor Authentication (TFA) while resetting a user password but enforces it for all other login scenarios. IBM X-Force ID: 144483.
An issue was discovered in myStrom WiFi Switch V1 before 2.66, WiFi Switch V2 before 3.80, WiFi Switch EU before 3.80, WiFi Bulb before 2.58, WiFi LED Strip before 3.80, WiFi Button before 2.73, and WiFi Button Plus before 2.73. The process of registering a device with a cloud account was based on an activation code derived from the device MAC address. By guessing valid MAC addresses or using MAC addresses printed on devices in shops and reverse engineering the protocol, an attacker would have been able to register previously unregistered devices to their account. When the rightful owner would have connected them after purchase to their WiFi network, the devices would not have registered with their account, would subsequently not have been controllable from the owner's mobile app, and would not have been visible in the owner's account. Instead, they would have been under control of the attacker.
Due to the lack of firmware authentication in the upgrade process of T&W WIFI Repeater BE126 devices, an attacker can craft a malicious firmware and use it as an update.
Intelbras NPLUG 1.0.0.14 wireless repeater devices have a critical vulnerability that allows an attacker to authenticate in the web interface just by using "admin:" as the name of a cookie.
Multiple vulnerabilities in the web-based management interface of Cisco Small Business 220 Series Smart Switches could allow an attacker to do the following: Hijack a user session Execute arbitrary commands as a root user on the underlying operating system Conduct a cross-site scripting (XSS) attack Conduct an HTML injection attack For more information about these vulnerabilities, see the Details section of this advisory.
In Apache Karaf version prior to 3.0.9, 4.0.9, 4.1.1, when the webconsole feature is installed in Karaf, it is available at .../system/console and requires authentication to access it. One part of the console is a Gogo shell/console that gives access to the command line console of Karaf via a Web browser, and when navigated to it is available at .../system/console/gogo. Trying to go directly to that URL does require authentication. And optional bundle that some applications use is the Pax Web Extender Whiteboard, it is part of the pax-war feature and perhaps others. When it is installed, the Gogo console becomes available at another URL .../gogo/, and that URL is not secured giving access to the Karaf console to unauthenticated users. A mitigation for the issue is to manually stop/uninstall Gogo plugin bundle that is installed with the webconsole feature, although of course this removes the console from the .../system/console application, not only from the unauthenticated endpoint. One could also stop/uninstall the Pax Web Extender Whiteboard, but other components/applications may require it and so their functionality would be reduced/compromised.
A flaw was found in Moodle 3.4 to 3.4.1, and 3.3 to 3.3.4. If a user account using OAuth2 authentication method was once confirmed but later suspended, the user could still login to the site.