A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
includes/class-coming-soon-creator.php in the igniteup plugin through 3.4 for WordPress allows information disclosure.
An issue was discovered in CIPPlanner CIPAce 6.80 Build 2016031401. GetDistributedPOP3 allows attackers to obtain the username and password of the SMTP user.
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.
Honeywell equIP and Performance series IP cameras, multiple versions, A vulnerability exists where the affected product allows unauthenticated access to audio streaming over HTTP.
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
Various Lexmark products have Incorrect Access Control (issue 2 of 2).
Unauthenticated password hash disclosure in the User.getUserPWD method in eQ-3 AG Homematic CCU3 3.43.15 and earlier allows remote attackers to retrieve the GUI password hashes of GUI users. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
The Glen Dimplex Deutschland GmbH implementation of the Carel pCOWeb configuration tool allows remote attackers to obtain access via an HTTP session on port 10000, as demonstrated by reading the modem password (which is 1234), or reconfiguring "party mode" or "vacation mode."
Various Lexmark products have Incorrect Access Control (issue 1 of 2).
The /rest/api/latest/groupuserpicker resource in Jira before version 8.4.0 allows remote attackers to enumerate usernames via an information disclosure vulnerability.
IBM Security Identity Governance and Intelligence 5.2.3.2 and 5.2.4 could allow an attacker to obtain sensitive information due to missing authentication in IGI for the survey application. IBM X-Force ID: 148601.
An issue was discovered in the Infosysta "In-App & Desktop Notifications" app 1.6.13_J8 for Jira. By using plugins/servlet/nfj/PushNotification?username= with a modified username, a different user's notifications can be read without authentication/authorization. These notifications are then no longer displayed to the normal user.
The WebApp v04.68 in the supervisor on SAET Impianti Speciali TEBE Small 05.01 build 1137 devices allows remote attackers to make several types of API calls without authentication, as demonstrated by retrieving password hashes via an inc/utils/REST_API.php?command=CallAPI&customurl=alladminusers call.
The administrative web server component of TIBCO Software Inc.'s TIBCO ActiveMatrix BPM, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric, TIBCO ActiveMatrix Policy Director, TIBCO ActiveMatrix Service Bus, TIBCO ActiveMatrix Service Grid, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric, TIBCO Silver Fabric Enabler for ActiveMatrix BPM, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid contains a vulnerability that could theoretically allow an unauthenticated user to download a file with credentials information. Affected releases are TIBCO Software Inc.'s TIBCO ActiveMatrix BPM: versions up to and including 4.2.0, TIBCO ActiveMatrix BPM Distribution for TIBCO Silver Fabric: versions up to and including 4.2.0, TIBCO ActiveMatrix Policy Director: versions up to and including 1.1.0, TIBCO ActiveMatrix Service Bus: versions up to and including 3.3.0, TIBCO ActiveMatrix Service Grid: versions up to and including 3.3.1, TIBCO ActiveMatrix Service Grid Distribution for TIBCO Silver Fabric: versions up to and including 3.3.0, TIBCO Silver Fabric Enabler for ActiveMatrix BPM: versions up to and including 1.4.1, and TIBCO Silver Fabric Enabler for ActiveMatrix Service Grid: versions up to and including 1.3.1.
IBM Security Guardium 10.5, 10.6, and 11.0 could allow an unauthorized user to obtain sensitive information due to missing security controls. IBM X-Force ID: 141226.
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
An issue was discovered on LG GAMP-7100, GAPM-7200, and GAPM-8000 routers. An unauthenticated user can read a log file via an HTTP request containing its full pathname, such as http://192.168.0.1/var/gapm7100_${today's_date}.log for reading a filename such as gapm7100_190101.log.
The Amcrest IP2M-841B V2.520.AC00.18.R, Dahua IPC-XXBXX V2.622.0000000.9.R, Dahua IPC HX5X3X and HX4X3X V2.800.0000008.0.R, Dahua DH-IPC HX883X and DH-IPC-HX863X V2.622.0000000.7.R, Dahua DH-SD4XXXXX V2.623.0000000.7.R, Dahua DH-SD5XXXXX V2.623.0000000.1.R, Dahua DH-SD6XXXXX V2.640.0000000.2.R and V2.623.0000000.1.R, Dahua NVR5XX-4KS2 V3.216.0000006.0.R, Dahua NVR4XXX-4KS2 V3.216.0000006.0.R, and NVR2XXX-4KS2 do not require authentication to access the HTTP endpoint /videotalk. An unauthenticated, remote person can connect to this endpoint and potentionally listen to the audio of the capturing device.
IBM Robotic Process Automation with Automation Anywhere 11 could allow an attacker to obtain sensitive information due to missing authentication in Ignite nodes. IBM X-Force ID: 161412.
An issue was discovered in Scytl sVote 2.1. Because the sdm-ws-rest API does not require authentication, an attacker can retrieve the administrative configuration by sending a POST request to the /sdm-ws-rest/preconfiguration URI.
An issue was discovered on Samsung mobile devices with N(7.x) and O(8.x) software. S-Voice leaks keyboard learned words via the lock screen. The Samsung ID is SVE-2018-12981 (February 2019).
An issue was discovered on Samsung mobile devices with O(8.x), P(9.0), and Q(10.0) software. Attackers can access the Developer options without authentication. The Samsung ID is SVE-2019-15800 (December 2019).
Zoho ManageEngine Applications Manager 14 before 14520 allows a remote unauthenticated attacker to disclose OS file names via FailOverHelperServlet.
The Recruitment module in Humanica Humatrix 7 1.0.0.203 and 1.0.0.681 allows an unauthenticated attacker to access all candidates' files in the photo folder on the website by specifying a "user id" parameter and file name, such as in a recruitment_online/upload/user/[user_id]/photo/[file_name] URI.
Zoho ManageEngine Applications Manager before 14600 allows a remote unauthenticated attacker to disclose license related information via WieldFeedServlet servlet.
D-Link DAP-1320 A2-V1.21 routers have some web interfaces without authentication requirements, as demonstrated by uplink_info.xml. An attacker can remotely obtain a user's Wi-Fi SSID and password, which could be used to connect to Wi-Fi or perform a dictionary attack.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can get the router's log file via log_get.php, which could be used to discover the intranet network structure.
DTEN D5 and D7 before 1.3.2 devices allows remote attackers to read saved whiteboard image PDF documents via storage/emulated/0/Notes/PDF on TCP port 8080 without authentication.
An issue was discovered in the Infosysta "In-App & Desktop Notifications" app 1.6.13_J8 for Jira. It is possible to obtain a list of all valid Jira usernames without authentication/authorization via the plugins/servlet/nfj/UserFilter?searchQuery=@ URI.
A vulnerability in the web-based management interface of Cisco UCS Director could allow an unauthenticated, remote attacker to download system log files from an affected device. The vulnerability is due to an issue in the authentication logic of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted request to the web interface. A successful exploit could allow the attacker to download log files if they were previously generated by an administrator.
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to access potentially sensitive system usage information. The vulnerability is due to a lack of proper data protection mechanisms. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow an attacker to view sensitive system data.
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
An issue was discovered in Kaseya Virtual System Administrator (VSA) through 9.4.0.37. It has a critical information disclosure vulnerability. An unauthenticated attacker can send properly formatted requests to the web application and download sensitive files and information. For example, the /DATAREPORTS directory can be farmed for reports. Because this directory contains the results of reports such as NMAP, Patch Status, and Active Directory domain metadata, an attacker can easily collect this critical information and parse it for information. There are a number of directories affected.
A vulnerability in the web-based management interface of Cisco Identity Services Engine (ISE) Software could allow an unauthenticated, remote attacker read tcpdump files generated on an affected device. The vulnerability is due an issue in the authentication logic of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted request to the web interface. A successful exploit could allow the attacker to read a tcpdump file generated with a particular naming scheme.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
D-Link DSL-2875AL devices through 1.00.05 are prone to password disclosure via a simple crafted /romfile.cfg request to the web management server. This request doesn't require any authentication and will lead to saving the configuration file. The password is stored in cleartext.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
Sphinx Technologies Sphinx 3.1.1 by default has no authentication and listens on 0.0.0.0, making it exposed to the internet (unless filtered by a firewall or reconfigured to listen to 127.0.0.1 only).
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
The CACAGOO Cloud Storage Intelligent Camera TV-288ZD-2MP with firmware 3.4.2.0919 allows access to the RTSP service without a password.
Anviz access control devices expose private Information (pin code and name) by allowing remote attackers to query this information without credentials via port tcp/5010.
Lack of authentication in case-exporting components in DDRT Dashcom Live through 2019-05-08 allows anyone to remotely access all claim details by visiting easily guessable exportpdf/all_claim_detail.php?claim_id= URLs.
Anviz access control devices expose credentials (names and passwords) by allowing remote attackers to query this information without credentials via port tcp/5010.
All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.
Some Brother printers (such as the HL-L8360CDW v1.20) were affected by different information disclosure vulnerabilities that provided sensitive information to an unauthenticated user who visits a specific URL.
In WESEEK GROWI before 3.5.0, a remote attacker can obtain the password hash of the creator of a page by leveraging wiki access to make API calls for page metadata. In other words, the password hash can be retrieved even though it is not a publicly available field.
A vulnerability classified as problematic has been found in SourceCodester Book Store Management System 1.0. This affects an unknown part of the file /bsms_ci/index.php/user/edit_user/. The manipulation of the argument password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214587.
Several web interfaces in D-Link DIR-868LW 1.12b have no authentication requirements for access, allowing for attackers to obtain users' DNS query history.