A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:24 Dec, 2018 | 16:00
Updated At:05 Aug, 2024 | 06:37
Rejected At:
▼CVE Numbering Authority (CNA)

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

Affected Products
Vendor
Schneider Electric SESchneider Electric SE
Product
PowerSuite 2, All released versions (VW3A8104 & Patches)
Versions
Affected
  • PowerSuite 2, All released versions (VW3A8104 & Patches)
Problem Types
TypeCWE IDDescription
textN/ABuffer Error
Type: text
CWE ID: N/A
Description: Buffer Error
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/
x_refsource_CONFIRM
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/
x_refsource_CONFIRM
x_transferred
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:24 Dec, 2018 | 16:29
Updated At:11 Jan, 2019 | 18:54

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

Schneider Electric SE
schneider-electric
>>powersuite_2>>*
cpe:2.3:a:schneider-electric:powersuite_2:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarynvd@nist.gov
CWE ID: CWE-119
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/cybersecurity@se.com
Vendor Advisory
Hyperlink: https://www.schneider-electric.com/en/download/document/SEVD-2018-351-01/
Source: cybersecurity@se.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

2108Records found

CVE-2020-7554
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 71.55%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-7918
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-13.26% / 94.30%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-7550
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 71.55%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:06
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-8561
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-4.61% / 89.48%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22761
Matching Score-10
Assigner-Schneider Electric
ShareView Details
Matching Score-10
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.28%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-6822
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.85% / 75.26%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:46
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.

Action-Not Available
Vendor-
Product-zelio_soft_2Zelio Soft 2 V5.2 and prior
CWE ID-CWE-416
Use After Free
CVE-2019-6826
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.01%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:57
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product.

Action-Not Available
Vendor-
Product-somachine_hvacSoMachine HVAC
CWE ID-CWE-426
Untrusted Search Path
CVE-2019-6832
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.3||HIGH
EPSS-0.34% / 57.21%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:31
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.

Action-Not Available
Vendor-
Product-wiser_for_knx_firmwarespacelynk_firmwarelss100100lss100200spaceLYnkWiser for KNX
CWE ID-CWE-287
Improper Authentication
CVE-2019-6827
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.19% / 40.58%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:47
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Version 14 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2013-0663
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-0.36% / 58.84%
||
7 Day CHG~0.00%
Published-04 Apr, 2013 | 10:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m340modicon_quantum_plcmodicon_premiumn/a
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2021-22697
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.71% / 72.64%
||
7 Day CHG~0.00%
Published-25 Jan, 2021 | 17:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.

Action-Not Available
Vendor-n/a
Product-ecostruxure_power_build_-_rapsody EcoStruxure Power Build - Rapsody software V2.1.13 and prior. 
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-22757
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.49% / 66.11%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-125
Out-of-bounds Read
CVE-2016-5809
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.93% / 76.54%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-ion5000ion8650ion8800ion7300ion7500ion7600Schneider Electric IONXXXX Series
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2022-32530
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-4.8||MEDIUM
EPSS-0.14% / 34.09%
||
7 Day CHG~0.00%
Published-24 Jun, 2022 | 13:00
Updated-03 Aug, 2024 | 07:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)

Action-Not Available
Vendor-
Product-geo_scada_mobileGeo SCADA Mobile
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2021-22807
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.37% / 59.04%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior

Action-Not Available
Vendor-n/a
Product-guiconn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22808
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.52% / 67.00%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior

Action-Not Available
Vendor-n/a
Product-guiconn/a
CWE ID-CWE-416
Use After Free
CVE-2021-22826
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.72% / 72.97%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions

Action-Not Available
Vendor-n/a
Product-ecostruxure_power_monitoring_expertn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22777
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.36% / 58.31%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file.

Action-Not Available
Vendor-n/a
Product-sosafe_configurableSoSafe Configurable prior to V1.8.1
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2021-22752
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22758
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2021-22755
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.49% / 66.11%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22762
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.61% / 70.22%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22750
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22718
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-10.78% / 93.50%
||
7 Day CHG~0.00%
Published-13 Apr, 2021 | 18:31
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.

Action-Not Available
Vendor-n/a
Product-c-bus_toolkitC-Bus Toolkit V1.15.7 and prior
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22751
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.37% / 59.04%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22754
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22827
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.72% / 72.97%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions

Action-Not Available
Vendor-n/a
Product-ecostruxure_power_monitoring_expertn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2021-22698
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-1.38% / 80.69%
||
7 Day CHG~0.00%
Published-25 Jan, 2021 | 17:10
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.

Action-Not Available
Vendor-n/a
Product-ecostruxure_power_build_-_rapsody EcoStruxure Power Build - Rapsody software V2.1.13 and prior. 
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-22796
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.63% / 70.76%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)

Action-Not Available
Vendor-n/a
Product-c-gate_serverC-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
CWE ID-CWE-287
Improper Authentication
CVE-2021-22759
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.51% / 66.73%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-416
Use After Free
CVE-2021-22753
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-22756
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.43% / 63.19%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-7801
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-7.04% / 91.66%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Code Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable access with maximum privileges when a remote code execution is performed.

Action-Not Available
Vendor-
Product-evlink_parkingevlink_parking_firmwareEVLink Parking v3.2.0-12_v1 and earlier
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2018-7230
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.34% / 57.19%
||
7 Day CHG~0.00%
Published-09 Mar, 2018 | 23:00
Updated-17 Sep, 2024 | 03:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.

Action-Not Available
Vendor-
Product-imp519-1er_firmwareibp319-1erimp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimp319-1mps110-1ibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1ermps110-1_firmwarePelco Sarix Professional
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2018-7817
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.67% / 71.66%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 23:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when opening a specially crafted Zelio Soft project file.

Action-Not Available
Vendor-
Product-zelio_soft_2Zelio Soft 2 v5.1 and prior versions
CWE ID-CWE-416
Use After Free
CVE-2018-7773
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 17:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7814
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.24% / 47.86%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 23:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file

Action-Not Available
Vendor-
Product-guiconEurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-7765
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-6.49% / 91.28%
||
7 Day CHG+0.40%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7813
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.19% / 40.58%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 23:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on pcwin.dll which could cause remote code to be executed when parsing a GD1 file

Action-Not Available
Vendor-
Product-guiconEurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)
CWE ID-CWE-704
Incorrect Type Conversion or Cast
CVE-2018-7828
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.54%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:34
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Cross-Site Request Forgery (CSRF) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera when an authenticated user clicks a specially crafted malicious link while logged into the camera.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2018-7815
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.19% / 40.58%
||
7 Day CHG~0.00%
Published-06 Feb, 2019 | 23:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on c3core.dll which could cause remote code to be executed when parsing a GD1 file

Action-Not Available
Vendor-
Product-guiconEurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)
CWE ID-CWE-704
Incorrect Type Conversion or Cast
CVE-2018-7767
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 02:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7768
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7769
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7774
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 23:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2018-7766
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.04%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-16 Sep, 2024 | 18:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

Action-Not Available
Vendor-
Product-u.motion_builderU.Motion
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7558
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 71.55%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7528
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.41% / 61.47%
||
7 Day CHG~0.00%
Published-16 Sep, 2020 | 15:39
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer.

Action-Not Available
Vendor-n/a
Product-scadapack_7x_remote_connectSCADAPack 7x Remote Connect V3.6.3.574 and prior.
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2020-7552
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.68% / 72.06%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7555
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 71.55%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:08
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 42
  • 43
  • Next
Details not found