A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software.
In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause certain data to be visible on the network when the 'password' feature is enabled. This vulnerability was discovered in and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. The 'password' feature is an additional optional check performed by TS1131 that it is connected to a specific controller. This data is sent as clear text and is visible on the network. This feature is not present in TriStation 1131 versions v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to acquire a password by brute force.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP.
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.
A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.
The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon M221 (all references, all versions) that could allow non sensitive information disclosure when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exist in AccuSine PCS+ / PFV+ (Versions prior to V1.6.7) and AccuSine PCSn (Versions prior to V2.2.4) that could allow an authenticated attacker to access the device via FTP protocol.
CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.
An issue was discovered in SMA Solar Technology products. When signed into Sunny Explorer with a wrong password, it is possible to create a debug report, disclosing information regarding the application and allowing the attacker to create and save a .txt file with contents to his liking. An attacker may use this for information disclosure, or to write a file to normally unavailable locations on the local system. NOTE: the vendor reports that "the information contained in the debug report is of marginal significance." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
The login function in Softaculous Webuzo before 2.1.4 provides different error messages for invalid authentication attempts depending on whether the user account exists, which allows remote attackers to enumerate usernames via a series of requests.
The XSSAuditor::init function in core/html/parser/XSSAuditor.cpp in the XSS auditor in Blink, as used in Google Chrome before 33.0.1750.117, processes POST requests by using the body of a redirecting page instead of the body of a redirect target, which allows remote attackers to obtain sensitive information via unspecified vectors.
NestJS Proxy is a NestJS module to decorate and proxy calls. Prior to version 0.7.0, the nestjs-proxy library did not have a way to block sensitive cookies (e.g. session cookies) from being forwarded to backend services configured by the application developer. This could have led to sensitive cookies being inadvertently exposed to such services that should not see them. The patched version now blocks cookies from being forwarded by default. However developers can configure an allow-list of cookie names by using the `allowedCookies` config setting. This issue has been fixed in version 0.7.0 of `@finastra/nestjs-proxy`. Users of `@ffdc/nestjs-proxy` are advised that this package has been deprecated and is no longer being maintained or receiving updates. Such users should update their package.json file to use `@finastra/nestjs-proxy` instead.
A path traversal flaw was found in the Ceph dashboard implemented in upstream versions v14.2.5, v14.2.6, v15.0.0 of Ceph storage and has been fixed in versions 14.2.7 and 15.1.0. An unauthenticated attacker could use this flaw to cause information disclosure on the host machine running the Ceph dashboard.
Exposure of Sensitive Information vulnerability in Samsung Account prior to version 13.2.00.6 allows attacker to access sensitive information via onActivityResult.
Improper privilege management vulnerability in Samsung Account prior to 13.2.00.6 allows attackers to get the data of contact and gallery without permission.
The CentralAuth extension for MediaWiki before 1.19.10, 1.2x before 1.21.4, and 1.22.x before 1.22.1 allows remote attackers to obtain usernames via vectors related to writing the names to the DOM of a page.
QNAP Photo Station before firmware 4.0.3 build0912 allows remote attackers to list OS user accounts via a request to photo/p/api/list.php.
An issue was discovered in certain Apple products. iOS before 11 is affected. Safari before 11 is affected. iCloud before 7.0 on Windows is affected. iTunes before 12.7 on Windows is affected. tvOS before 11 is affected. The issue involves the "WebKit" component. It allows remote attackers to bypass the Same Origin Policy and obtain sensitive cookie information via a custom URL scheme.
Brave before 1.34, when a Private Window with Tor Connectivity is used, leaks .onion URLs in Referer and Origin headers. NOTE: although this was fixed by Brave, the Brave documentation still advises "Note that Private Windows with Tor Connectivity in Brave are just regular private windows that use Tor as a proxy. Brave does NOT implement most of the privacy protections from Tor Browser."
A Content Provider in Firefox for Android allowed local files accessible by the browser to be read by a remote webpage, leading to sensitive data disclosure, including cookies for other origins. This vulnerability affects Firefox for < Android.
Netwrix Account Lockout Examiner before 5.1 allows remote attackers to capture the Net-NTLMv1/v2 authentication challenge hash of the Domain Administrator (that is configured within the product in its installation state) by generating a single Kerberos Pre-Authentication Failed (ID 4771) event on a Domain Controller.
Sensitive information disclosure due to insecure folder permissions. The following products are affected: Acronis Cyber Protect 15 (Linux) before build 29240, Acronis Agent (Linux) before build 28037
IBM WebSphere Application Server (WAS) before 6.0.2.13 allows context-dependent attackers to obtain sensitive information via unspecified vectors related to "JSP source code exposure" (PK23475), which occurs when ibm-web-ext.xmi sets fileServingEnabled to true or ExtendedDocumentRoot is used to place a JSP outside a WAR.file; (3) the First Failure Data Capture (ffdc) log file (PK24834); and (4) traces (PK25568), a different issue than CVE-2006-4137.
QNAP Qfinder Pro 6.1.0.0317 and earlier may expose sensitive information contained in NAS devices. If exploited, this may allow attackers to further compromise the device.
Red Hat Conga 0.12.2 allows remote attackers to obtain sensitive information via a crafted request to the (1) homebase, (2) cluster, (3) storage, (4) portal_skins/custom, or (5) logs Luci extension.