A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which could allow arbitrary code execution when an attacker builds a custom .PRJ file containing a malicious serialized buffer.
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-284 Improper Access Control vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place executables in a specific folder and run code whenever RemoteConnect is executed by the user.
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxureâ„¢ Control Expert (all versions) and Unity Pro (former name of EcoStruxureâ„¢ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxureâ„¢ Control Expert software.
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
A CWE-502 Deserialization of Untrusted Data vulnerability exists in SCADAPack x70 Security Administrator (V1.2.0 and prior) which could allow arbitrary code execution when an attacker builds a custom .SDB file containing a malicious serialized buffer.
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0.
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be embedded in the HTTP cookie of the request.
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data.
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system�s configurations when an attacker persuades a user to visit a rogue website. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
The Insights from Google PageSpeed WordPress plugin before 4.0.7 does not verify for CSRF before doing various actions such as deleting Custom URLs, which could allow attackers to make a logged in admin perform such actions via CSRF attacks
The Copify plugin for WordPress is vulnerable to Cross-Site Request Forgery in versions up to, and including, 1.3.0. This is due to missing nonce validation on the CopifySettings page. This makes it possible for unauthenticated attackers to update the plugins settings and inject malicious web scripts via a forged request granted they can trick a site administrator into performing an action such as clicking on a link.
The Hot Linked Image Cacher WordPress plugin through 1.16 is vulnerable to CSRF. This can be used to store / cache images from external domains on the server, which could lead to legal risks (due to copyright violations or licensing rules).
Jenkins GitHub Authentication Plugin 0.31 and earlier did not use the state parameter of OAuth to prevent CSRF.
An issue was discovered in Aviatrix Controller before 5.4.1204. An API call on the web interface lacked a session token check to control access, leading to CSRF.
iSmartgate PRO 1.5.9 is vulnerable to CSRF via the busca parameter in the form used for searching for users, accessible via /index.php. (This can be combined with reflected XSS.)
The jayj-quicktag plugin before 1.3.2 for WordPress has CSRF.
Combodo iTop contains a cross-site request forgery (CSRF) vulnerability, attackers can execute specific commands via malicious site request forgery.
The data-tables-generator-by-supsystic plugin before 1.9.92 for WordPress lacks CSRF nonce checks for AJAX actions. One consequence of this is stored XSS.
Cross-site request forgery (CSRF) vulnerability in Opsview before 4.4.2 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
CFME: CSRF protection vulnerability via permissive check of the referrer header
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) and ICRL-M-8RJ45/4SFP-G-DIN, ICRL-M-16RJ45/4CP-G-DIN FW 1.2.3 and below is prone to unauthenticated device administration.
The Bulk Page Creator WordPress plugin before 1.1.4 does not protect its page creation functionalities with nonce checks, which makes them vulnerable to CSRF.
The Western Digital WD Discovery application before 3.8.229 for MyCloud Home on Windows and macOS is vulnerable to CSRF, with impacts such as stealing data, modifying disk contents, or exhausting disk space.
VMware AirWatch Console (9.2.x before 9.2.2 and 9.1.x before 9.1.5) contains a Cross Site Request Forgery vulnerability when accessing the App Catalog. An attacker may exploit this issue by tricking users into installing a malicious application on their devices.
clearsystem.php in NukeViet 4.4 allows CSRF with resultant HTML injection via the deltype parameter to the admin/index.php?nv=webtools&op=clearsystem URI.
An issue was discovered in Logitech Options. The OAuth 2.0 state parameter was not properly validated. This leaves applications vulnerable to CSRF attacks during authentication and authorization operations.
Cross-site request forgery (CSRF) vulnerability in D-Link DAP-2253 Access Point (Rev. A1) with firmware before 1.30 allows remote attackers to hijack the authentication of administrators for requests that modify configuration settings via unspecified vectors.
Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface.
The Login/Signup Popup, Waitlist Woocommerce ( Back in stock notifier ), and Side Cart Woocommerce (Ajax) WordPress plugins by XootiX are vulnerable to Cross-Site Request Forgery via the save_settings function found in the ~/includes/xoo-framework/admin/class-xoo-admin-settings.php file which makes it possible for attackers to update arbitrary options on a site that can be used to create an administrative user account and grant full privileged access to a compromised site. This affects versions <= 2.2 in Login/Signup Popup, versions <= 2.5.1 in Waitlist Woocommerce ( Back in stock notifier ), and versions <= 2.0 in Side Cart Woocommerce (Ajax).
rConfig 3.9.4 is vulnerable to cross-site request forgery (CSRF) because it lacks implementation of CSRF protection such as a CSRF token. An attacker can leverage this vulnerability by creating a form (add a user, delete a user, or edit a user).