iBaby M3S has a password of admin for the backdoor admin account.
An attacker without authentication can login with default credentials for privileged users in Eltex ESP-200 firmware version 1.2.0.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
In certain devices of the Phoenix Contact AXL F BK and IL BK product families an undocumented password protected FTP access to the root directory exists.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / lnadmin credentials for an ISP.
Use of MAC address as an authenticated password in QSAN Storage Manager, XEVO, SANOS allows local attackers to escalate privileges. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
The vulnerability of hard-coded default credentials in QSAN SANOS allows unauthenticated remote attackers to obtain administrator’s permission and execute arbitrary functions. The referred vulnerability has been solved with the updated version of QSAN SANOS v2.1.0.
Unsafe storage of AD credentials in Ivanti DSM netinst 5.1 due to a static, hard-coded encryption key.
The server API in the Anda app relies on hardcoded credentials.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Use of a Hard-coded Cryptographic Key used to protect cookie session data in /var/www/xms/application/config/config.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to bypass authentication.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Use of Hard-coded Credentials in /var/www/xms/application/controllers/gatherLogs.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to interact with a web service.
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 888888 credentials for an ISP.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded rootmet / m3tr0r00t credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded useradmin / 888888 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded trueadmin / admintrue credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded telecomadmin / nE7jA%5m credentials for an ISP.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded awnfibre / fibre@dm!n credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / aisadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded L1vt1m4eng / 888888 credentials for an ISP.
Directus 6.4.9 has a hardcoded admin password for the Admin account because of an INSERT statement in api/schema.sql.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / 888888 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded gestiontelebucaramanga / t3l3buc4r4m4ng42013 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded adminpldt / z6dUABtl270qRxt7a2uGTiw credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / CUadmin credentials for an ISP.
Brocade Fabric OS before Brocade Fabric OS v8.2.1c, v8.1.2h, and all versions of Brocade Fabric OS v8.0.x and v7.x contain documented hard-coded credentials, which could allow attackers to gain access to the system.
HejHome GKW-IC052 IP Camera contained a hard-coded credentials vulnerability. This issue allows remote attackers to operate the IP Camera.(reboot, factory reset, snapshot etc..)
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 1234 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 3UJUh2VemEfUtesEchEC2d2e credentials for an ISP.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.