CVE-2019-13919

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-13 Sep, 2019 | 16:38
Updated At-05 Aug, 2024 | 00:05
Rejected At-
Credits

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:13 Sep, 2019 | 16:38
Updated At:05 Aug, 2024 | 00:05
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected Products
Vendor
Siemens AGSiemens AG
Product
SINEMA Remote Connect Server
Versions
Affected
  • All versions < V2.0 SP1
Problem Types
TypeCWE IDDescription
CWECWE-284CWE-284: Improper Access Control
Type: CWE
CWE ID: CWE-284
Description: CWE-284: Improper Access Control
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:13 Sep, 2019 | 17:15
Updated At:02 Nov, 2021 | 20:02

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some pages that should only be accessible by a privileged user can also be accessed by a non-privileged user. The security vulnerability could be exploited by an attacker with network access and valid credentials for the web interface. No user interaction is required. The vulnerability could allow an attacker to access information that he should not be able to read. The affected information does not include passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.14.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Primary2.04.0MEDIUM
AV:N/AC:L/Au:S/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 4.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Type: Primary
Version: 2.0
Base score: 4.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:N/A:N
CPE Matches

Siemens AG
siemens
>>sinema_remote_connect_server>>Versions up to 2.0(inclusive)
cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinema_remote_connect_server>>2.0
cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-OtherPrimarynvd@nist.gov
CWE-284Secondaryproductcert@siemens.com
CWE ID: NVD-CWE-Other
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-284
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

288Records found

CVE-2022-32256
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.63% / 46.22%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-284
Improper Access Control
CVE-2017-6866
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.05% / 60.59%
||
7 Day CHG~0.00%
Published-07 Aug, 2017 | 23:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.

Action-Not Available
Vendor-n/aSiemens AG
Product-xhq_serverXHQ 4 (All versions before V4.7.1.3), XHQ 5 (All versions before V5.0.0.2)
CWE ID-CWE-284
Improper Access Control
CVE-2021-41543
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.73% / 50.34%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The handling of log files in the web application of affected devices contains an information disclosure vulnerability which could allow logged in users to access sensitive files.

Action-Not Available
Vendor-Siemens AG
Product-climatix_pol909_firmwareclimatix_pol909Climatix POL909 (AWM module)Climatix POL909 (AWB module)
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2018-4861
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-1.90% / 77.40%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could potentially read and download arbitrary files from the device's file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-scalance_m875scalance_m875_firmwareSCALANCE M875
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2026-27661
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 17.33%
||
7 Day CHG~0.00%
Published-10 Mar, 2026 | 16:07
Updated-17 Mar, 2026 | 16:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application leaks confidential information in metadata, and files such as information on contributors and email address, on `SSM Server`.

Action-Not Available
Vendor-Siemens AG
Product-sinec_security_monitorSINEC Security Monitor
CWE ID-CWE-1230
Exposure of Sensitive Information Through Metadata
CVE-2022-29879
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.78% / 51.88%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow authenticated users to access critical device information.

Action-Not Available
Vendor-Siemens AG
Product-7kg8551-0aa12-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa31-2aa07kg8500-0aa30-2aa07kg8551-0aa32-2aa07kg8551-0aa01-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa32-0aa07kg8551-0aa02-0aa07kg8501-0aa31-0aa07kg8501-0aa12-0aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8551-0aa12-0aa07kg8501-0aa02-0aa0_firmware7kg8551-0aa31-2aa0_firmware7kg8551-0aa32-0aa07kg8551-0aa02-2aa0_firmware7kg8501-0aa11-0aa07kg8551-0aa01-2aa07kg8500-0aa00-2aa07kg8551-0aa31-0aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa07kg8501-0aa11-0aa0_firmware7kg8500-0aa10-0aa07kg8550-0aa00-0aa07kg8500-0aa00-2aa0_firmware7kg8501-0aa32-2aa07kg8500-0aa00-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8550-0aa00-2aa0_firmware7kg8501-0aa12-2aa07kg8551-0aa11-0aa07kg8501-0aa12-2aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa11-2aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa31-2aa07kg8551-0aa31-0aa07kg8500-0aa10-0aa0_firmware7kg8551-0aa12-2aa07kg8551-0aa11-2aa07kg8501-0aa11-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa00-0aa07kg8551-0aa01-2aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-2aa07kg8550-0aa30-0aa0_firmware7kg8500-0aa30-2aa0_firmware7kg8551-0aa01-0aa07kg8550-0aa10-0aa07kg8500-0aa10-2aa07kg8501-0aa12-0aa07kg8550-0aa00-0aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8501-0aa02-2aa07kg8551-0aa11-0aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8551-0aa02-2aa07kg8551-0aa32-0aa0_firmware7kg8501-0aa01-2aa07kg8501-0aa02-2aa0_firmware7kg8501-0aa32-0aa0_firmware7kg8501-0aa31-0aa0_firmware7kg8501-0aa01-0aa07kg8550-0aa10-2aa0_firmwareSICAM T
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-30231
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.58% / 43.66%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:21
Updated-12 Nov, 2025 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash.

Action-Not Available
Vendor-Siemens AG
Product-sicam_gridedge_essentialSICAM GridEdge (Classic)
CWE ID-CWE-402
Transmission of Private Resources into a New Sphere ('Resource Leak')
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2022-24041
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.45% / 36.35%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:46
Updated-03 Aug, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The web application stores the PBKDF2 derived key of users passwords with a low iteration count. An attacker with user profile access privilege can retrieve the stored password hashes of other accounts and then successfully perform an offline cracking attack and recover the plaintext passwords of other users.

Action-Not Available
Vendor-Siemens AG
Product-desigo_dxr2desigo_pxc3_firmwaredesigo_pxc4desigo_pxc5_firmwaredesigo_dxr2_firmwaredesigo_pxc4_firmwaredesigo_pxc3desigo_pxc5Desigo PXC5Desigo PXC3Desigo DXR2Desigo PXC4
CWE ID-CWE-916
Use of Password Hash With Insufficient Computational Effort
CVE-2022-24045
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.57% / 43.53%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:46
Updated-03 Aug, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). The application, after a successful login, sets the session cookie on the browser via client-side JavaScript code, without applying any security attributes (such as “Secure”, “HttpOnly”, or “SameSite”). Any attempts to browse the application via unencrypted HTTP protocol would lead to the transmission of all his/her session cookies in plaintext through the network. An attacker could then be able to sniff the network and capture sensitive information.

Action-Not Available
Vendor-Siemens AG
Product-desigo_dxr2desigo_pxc3_firmwaredesigo_pxc4desigo_dxr2_firmwaredesigo_pxc5_firmwaredesigo_pxc4_firmwaredesigo_pxc3desigo_pxc5Desigo PXC5Desigo PXC3Desigo DXR2Desigo PXC4
CWE ID-CWE-614
Sensitive Cookie in HTTPS Session Without 'Secure' Attribute
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2017-2686
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.15% / 63.29%
||
7 Day CHG~0.00%
Published-29 Mar, 2017 | 01:00
Updated-13 May, 2026 | 00:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_rox_iRUGGEDCOM ROX I All versions
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-285
Improper Authorization
CVE-2013-3959
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-4||MEDIUM
EPSS-1.33% / 67.95%
||
7 Day CHG~0.00%
Published-14 Jun, 2013 | 19:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2013-0671
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4||MEDIUM
EPSS-2.33% / 81.61%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 14:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.

Action-Not Available
Vendor-n/aSiemens AG
Product-wincc_tia_portaln/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2013-0676
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4||MEDIUM
EPSS-1.53% / 71.91%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 15:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CVE-2013-0678
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4||MEDIUM
EPSS-1.52% / 71.69%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 15:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CVE-2013-0679
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4||MEDIUM
EPSS-2.33% / 81.61%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 15:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccsimatic_pcs7n/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2012-2597
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-4||MEDIUM
EPSS-2.33% / 81.61%
||
7 Day CHG~0.00%
Published-08 Jun, 2012 | 18:00
Updated-29 Apr, 2026 | 01:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.

Action-Not Available
Vendor-n/aSiemens AG
Product-winccn/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-27462
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-3.1||LOW
EPSS-0.52% / 40.93%
||
7 Day CHG~0.00%
Published-14 Mar, 2023 | 09:32
Updated-27 Feb, 2025 | 15:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The client query handler of the affected application fails to check for proper permissions for specific read queries. This could allow authenticated remote attackers to access data they are not authorized for.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOW
CWE ID-CWE-862
Missing Authorization
CVE-2021-45106
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.68% / 48.10%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM TOOLBOX II (All versions). Affected applications use a circumventable access control within a database service. This could allow an attacker to access the database.

Action-Not Available
Vendor-Siemens AG
Product-sicam_toolbox_iiSICAM TOOLBOX II
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-40360
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.68% / 48.37%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2021-40357
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-1.17% / 63.81%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:48
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.10), Teamcenter Active Workspace V5.0 (All versions < V5.0.8), Teamcenter Active Workspace V5.1 (All versions < V5.1.5), Teamcenter Active Workspace V5.2 (All versions < V5.2.1). A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V4.3Teamcenter Active Workspace V5.0Teamcenter Active Workspace V5.2Teamcenter Active Workspace V5.1
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-19287
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.24% / 65.83%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow attackers to traverse through the file system of the server based by sending specially crafted packets over the network without authentication.

Action-Not Available
Vendor-Siemens AG
Product-xhqXHQ
CWE ID-CWE-23
Relative Path Traversal
CVE-2021-37734
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.5||MEDIUM
EPSS-0.95% / 57.16%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 15:16
Updated-04 Aug, 2024 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below; Aruba Instant 8.8.x.x: 8.8.0.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-40941
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-0.25% / 15.85%
||
7 Day CHG~0.00%
Published-09 Dec, 2025 | 10:44
Updated-10 Dec, 2025 | 21:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected devices exposes server information in its responses. This could allow an attacker with network access to gain useful information, increasing the likelihood of targeted attacks.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cn_4100_firmwaresimatic_cn_4100SIMATIC CN 4100
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-37733
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-4.9||MEDIUM
EPSS-1.15% / 63.41%
||
7 Day CHG~0.00%
Published-07 Sep, 2021 | 12:38
Updated-04 Aug, 2024 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote path traversal vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.1, 8.6.0.7, 8.5.0.11, 8.3.0.16. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-37200
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-37.38% / 98.36%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). An attacker with access to the webserver of an affected system could download arbitrary files from the underlying filesystem by sending a specially crafted HTTP request.

Action-Not Available
Vendor-Siemens AG
Product-sinec_network_management_systemSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-27392
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.18% / 64.28%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_open_network_bridgeSiveillance Video Open Network Bridge
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2023-29103
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.39% / 31.03%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC712 (All versions < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions < V2.1). The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.

Action-Not Available
Vendor-Siemens AG
Product-6gk1411-1ac00_firmware6gk1411-5ac00_firmware6gk1411-1ac006gk1411-5ac00SIMATIC Cloud Connect 7 CC716SIMATIC Cloud Connect 7 CC712
CWE ID-CWE-259
Use of Hard-coded Password
CVE-2021-37209
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.37% / 29.46%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 00:00
Updated-12 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rs969ruggedcom_rs910ruggedcom_rsg2100ruggedcom_rsg2300pruggedcom_rs930lruggedcom_rsg907rruggedcom_rsg910cruggedcom_rs416ruggedcom_rs900wruggedcom_i801ruggedcom_rosruggedcom_m2100ruggedcom_rmcruggedcom_i800ruggedcom_rst2228ruggedcom_rs930wruggedcom_rmc8388ruggedcom_rsg2200ruggedcom_rs900ruggedcom_rs401ruggedcom_rs8000truggedcom_rsg909rruggedcom_rp110ruggedcom_rs910lruggedcom_i802ruggedcom_m969ruggedcom_rs910wruggedcom_rsg2100pruggedcom_rs8000ruggedcom_rst916pruggedcom_rs900gpruggedcom_rs900lruggedcom_rmc40ruggedcom_rsl910ruggedcom_rmc41ruggedcom_rsg920pruggedcom_rs920wruggedcom_rs416v2ruggedcom_rs8000aruggedcom_rsg2300ruggedcom_rst916cruggedcom_m2200ruggedcom_rs400ruggedcom_rst2228pruggedcom_rmc20ruggedcom_rs8000hruggedcom_rsg908cruggedcom_i803ruggedcom_rsg2488ruggedcom_rs900gruggedcom_rsg2288ruggedcom_rs920lruggedcom_rs940gruggedcom_rmc30RUGGEDCOM RS8000RUGGEDCOM RS900LRUGGEDCOM RSG2300 V4.XRUGGEDCOM RSG920P V4.XRUGGEDCOM RS930WRUGGEDCOM RS910LRUGGEDCOM RS416v2 V5.XRUGGEDCOM RSG2300P V4.XRUGGEDCOM RSG2100 (32M) V5.XRUGGEDCOM RS416Pv2 V4.XRUGGEDCOM RS1600RUGGEDCOM RS920WRUGGEDCOM RS940GRUGGEDCOM M2200RUGGEDCOM RS910RUGGEDCOM RS900RUGGEDCOM RSG908CRUGGEDCOM RS920LRUGGEDCOM RMC8388 V4.XRUGGEDCOM RSG2100RUGGEDCOM RS8000HRUGGEDCOM RS400RUGGEDCOM RS8000TRUGGEDCOM RS900G (32M) V4.XRUGGEDCOM M969RUGGEDCOM RS900GRUGGEDCOM RS900M-STND-XXRUGGEDCOM RS8000ARUGGEDCOM RS900WRUGGEDCOM i803RUGGEDCOM RMC8388 V5.XRUGGEDCOM RSG910CRUGGEDCOM RSG2288 V4.XRUGGEDCOM RS969RUGGEDCOM RSG2200RUGGEDCOM RS900 (32M) V4.XRUGGEDCOM RSG909RRUGGEDCOM RS416RUGGEDCOM RST2228PRUGGEDCOM RSG2100PRUGGEDCOM i800RUGGEDCOM RS416PRUGGEDCOM RS900M-STND-C01RUGGEDCOM RS900M-GETS-XXRUGGEDCOM RST916PRUGGEDCOM RSG920P V5.XRUGGEDCOM RSG2100 (32M) V4.XRUGGEDCOM RSG2288 V5.XRUGGEDCOM RS1600FRUGGEDCOM RSL910RUGGEDCOM RSG907RRUGGEDCOM RS930LRUGGEDCOM RSG2300P V5.XRUGGEDCOM RS910WRUGGEDCOM RSG2300 V5.XRUGGEDCOM RST916CRUGGEDCOM RS900GPRUGGEDCOM RSG2488 V4.XRUGGEDCOM i802RUGGEDCOM RSG2100P (32M) V4.XRUGGEDCOM RSG2488 V5.XRUGGEDCOM RST2228RUGGEDCOM RS401RUGGEDCOM RMC30RUGGEDCOM M2100RUGGEDCOM RS1600TRUGGEDCOM RS900G (32M) V5.XRUGGEDCOM RS416Pv2 V5.XRUGGEDCOM RS900M-GETS-C01RUGGEDCOM RS900 (32M) V5.XRUGGEDCOM RP110RUGGEDCOM i801RUGGEDCOM RSG2100P (32M) V5.XRUGGEDCOM RS416v2 V4.X
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CWE ID-CWE-326
Inadequate Encryption Strength
CVE-2021-33727
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-0.82% / 53.29%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could download the user profile of any user. With this, the attacker could leak confidential information of any user in the affected system.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-25157
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-4.9||MEDIUM
EPSS-10.26% / 95.17%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 01:33
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.6 and below; Aruba Instant 8.7.x: 8.7.1.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CVE-2022-32254
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.79% / 52.06%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2021-33709
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.90% / 55.58%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V4Teamcenter Active Workspace V5.0Teamcenter Active Workspace V5.1
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-15794
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-0.77% / 51.65%
||
7 Day CHG~0.00%
Published-15 Oct, 2020 | 18:45
Updated-04 Aug, 2024 | 13:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo Insight (All versions). Some error messages in the web application show the absolute path to the requested resource. This could allow an authenticated attacker to retrieve additional information about the host system.

Action-Not Available
Vendor-Siemens AG
Product-desigo_insightDesigo Insight
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-209
Generation of Error Message Containing Sensitive Information
CVE-2020-15792
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.3||MEDIUM
EPSS-1.00% / 58.73%
||
7 Day CHG~0.00%
Published-15 Oct, 2020 | 18:45
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Desigo Insight (All versions). The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to retrieve data via a content-based blind SQL injection attack.

Action-Not Available
Vendor-Siemens AG
Product-desigo_insightDesigo Insight
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-19290
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.81% / 76.24%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The DOWNLOADS section in the web interface of the Control Center Server (CCS) contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-18338
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-2.65% / 83.92%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-15 Nov, 2024 | 14:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker with network access to the CCS server could exploit this vulnerability to list arbitrary directories or read files outside of the CCS application context.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2019-13929
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.5||MEDIUM
EPSS-1.27% / 66.64%
||
7 Day CHG~0.00%
Published-10 Oct, 2019 | 13:49
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_it_uadmSIMATIC IT UADM
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key
CWE ID-CWE-330
Use of Insufficiently Random Values
CVE-2019-13947
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-0.86% / 54.35%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The user configuration menu in the web interface of the Control Center Server (CCS) transfers user passwords in clear to the client (browser). An attacker with administrative privileges for the web interface could be able to read (and not only reset) passwords of other CCS users.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-317
Cleartext Storage of Sensitive Information in GUI
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2019-13922
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-2.7||LOW
EPSS-0.55% / 42.43%
||
7 Day CHG~0.00%
Published-13 Sep, 2019 | 16:38
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-311
Missing Encryption of Sensitive Data
CVE-2019-10938
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-1.49% / 71.29%
||
7 Day CHG~0.00%
Published-02 Aug, 2019 | 13:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions < V8.01), Siemens Power Meters Series 9410 (All versions < V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-6md857sa867sj826md867um857sj857ut86siprotec_5_digsi_device_driver7sa877vk877ve856md897ut877sa827ut857sl827sd867sl867sd827sk857sk827ut827sd877sj867sl87Siemens Power Meters Series 9410Siemens Power Meters Series 9810SIPROTEC 5 devices with CPU variants CP300 and CP100SIPROTEC 5 devices with CPU variants CP200
CWE ID-CWE-284
Improper Access Control
CVE-2018-4844
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-6.7||MEDIUM
EPSS-0.43% / 34.60%
||
7 Day CHG~0.00%
Published-20 Mar, 2018 | 14:00
Updated-17 Sep, 2024 | 03:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-simatic_wincc_oa_uiSIMATIC WinCC OA UI for Android, SIMATIC WinCC OA UI for iOS
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-269
Improper Privilege Management
CVE-2018-4858
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-1.84% / 76.61%
||
7 Day CHG~0.00%
Published-09 Jul, 2018 | 19:00
Updated-16 Sep, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-ec_61850_system_configurator_firmwaresicam_sccdigsi_5_firmwaredigsi_4_firmwaresicam_scc_firmwaresicam_pq_analyzersicam_pq_analyzer_firmwaredigsi_4sicam_pas\/pqsdigsi_5ec_61850_system_configuratorIEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC
CWE ID-CWE-284
Improper Access Control
CVE-2018-4845
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.16% / 63.67%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-rapidlab_1200_firmwarerapidpoint_500_firmwarerapidpoint_500rapidpoint_400_firmwarerapidlab_1200rapidpoint_400RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-269
Improper Privilege Management
CVE-2016-9155
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-2.33% / 81.64%
||
7 Day CHG~0.00%
Published-22 Nov, 2016 | 11:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.

Action-Not Available
Vendor-n/aSiemens AG
Product-ccis1425_firmwarecvmw3025-ir_firmwareccid1445-dn28cfmw1025_firmwareccpw3025ccms2025_firmwarecfmw1025cfmw3025ccid1445-dn36ccmw1025ccpw3025_firmwarecfmw3025_firmwareccid1445-dn18_firmwareccms2025ccmw1025_firmwareccid1445-dn28_firmwarecvmw3025-ircfms2025ccid1445-dn36_firmwarecvms2025-ir_firmwareccis1425cfis1425_firmwareccmw3025ccmd3025-dn18_firmwareccid1445-dn18ccmw3025_firmwarecfis1425ccmd3025-dn18cfms2025_firmwarecvms2025-irSIEMENS-branded IP Cameras
CWE ID-CWE-284
Improper Access Control
CVE-2016-9156
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-1.51% / 71.65%
||
7 Day CHG~0.00%
Published-05 Dec, 2016 | 08:09
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP.

Action-Not Available
Vendor-n/aSiemens AG
Product-sicam_pas\/pqsSiemens SICAM PAS through V8.08
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-284
Improper Access Control
CVE-2016-9157
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-3.26% / 86.97%
||
7 Day CHG~0.00%
Published-05 Dec, 2016 | 08:09
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to cause a Denial of Service condition and potentially lead to unauthenticated remote code execution by sending specially crafted packets to port 19234/TCP.

Action-Not Available
Vendor-n/aSiemens AG
Product-sicam_pas\/pqsSiemens SICAM PAS through V8.08
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-284
Improper Access Control
CVE-2016-8565
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.1||CRITICAL
EPSS-2.91% / 85.44%
||
7 Day CHG~0.00%
Published-13 Oct, 2016 | 10:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens Automation License Manager (ALM) before 5.3 SP3 allows remote attackers to write to files, rename files, create directories, or delete directories via crafted packets.

Action-Not Available
Vendor-n/aSiemens AG
Product-automation_license_managern/a
CWE ID-CWE-284
Improper Access Control
CVE-2015-6675
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.81% / 52.93%
||
7 Day CHG~0.00%
Published-11 Sep, 2015 | 16:00
Updated-06 May, 2026 | 22:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens RUGGEDCOM ROS 3.8.0 through 4.1.x permanently enables the IP forwarding feature, which allows remote attackers to bypass a VLAN isolation protection mechanism via IP traffic.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_rugged_operating_systemn/a
CWE ID-CWE-284
Improper Access Control
CVE-2018-13816
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-10||CRITICAL
EPSS-2.80% / 84.86%
||
7 Day CHG~0.00%
Published-12 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 09:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIM 1531 IRC (All version < V2.0). The devices was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-tim_1531_irc_firmwaretim_1531_ircTIM 1531 IRC
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-287
Improper Authentication
CVE-2022-38466
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.16% / 5.70%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 10:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CoreShield One-Way Gateway (OWG) Software (All versions < V2.2). The default installation sets insecure file permissions that could allow a local attacker to escalate privileges to local administrator.

Action-Not Available
Vendor-Siemens AG
Product-coreshield_one-way_gatewayCoreShield One-Way Gateway (OWG) Software
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-276
Incorrect Default Permissions