A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected application does not expire the session. This could allow an attacker to get unauthorized access.
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.
lookup in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
storeAtts in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker to execute arbitrary code.
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the names in DNS-responses. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80/TCP or port 443/TCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17293)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-043)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-042)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-051)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-046)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-037, FG-VD-22-059)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-045)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-044)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-040)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-049)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-054)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-039)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a type confusion vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14643, ZDI-CAN-14644, ZDI-CAN-14755, ZDI-CAN-15183)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15050)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14684)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14757)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14646, ZDI-CAN-14679, ZDI-CAN-15084, ZDI-CAN-15304)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14683, ZDI-CAN-15283, ZDI-CAN-15303, ZDI-CAN-15593)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15286)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15302)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602)
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Tiff_Loader.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15054)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14908)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14913)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14903)
A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains a use after free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14900)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14907)
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to stack based buffer overflow while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14845)
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14828, ZDI-CAN-14898)
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911)
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).
A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15039)
The jutil.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocation structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link.