An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module receives an IP fragmented packet with a length greater than 65535 bytes. The module then requires a power cycle to recover.
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol.
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
A Null Pointer Dereference issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The null pointer dereference vulnerability could allow an attacker to crash the logger process, causing a denial of service for logging and log-viewing (applications that use the Wonderware ArchestrA Logger continue to run when the Wonderware ArchestrA Logger service is unavailable).
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.
A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 (HTTP) and 502 (Modbus), when sending a large number of TCP RST or FIN packets to any open TCP port of the PLC. Affected Product: Modicon M340 CPUs: BMXP34 (All Versions)
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former 'password' feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller.
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol.
NLnet Labs Krill supports direct access to the RRDP repository content through its built-in web server at the "/rrdp" endpoint. Prior to 0.12.1 a direct query for any existing directory under "/rrdp/", rather than an RRDP file such as "/rrdp/notification.xml" as would be expected, causes Krill to crash. If the built-in "/rrdp" endpoint is exposed directly to the internet, then malicious remote parties can cause the publication server to crash. The repository content is not affected by this, but the availability of the server and repository can cause issues if this attack is persistent and is not mitigated.
Specifically crafted MongoDB wire protocol messages can cause mongos to crash during command validation. This can occur without using an authenticated connection. This issue affects MongoDB v5.0 versions prior to 5.0.31, MongoDB v6.0 versions prior to 6.0.20 and MongoDB v7.0 versions prior to 7.0.16
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the virtual tenant network application (org.onosproject.vtn), the host event listener does not handle the following event types: HOST_MOVED. In combination with other applications, this could lead to the absence of intended code execution.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the access control application (org.onosproject.acl), the host event listener does not handle the following event types: HOST_REMOVED. In combination with other applications, this could lead to the absence of intended code execution.
Unbound before 1.9.4 accesses uninitialized memory, which allows remote attackers to trigger a crash via a crafted NOTIFY query. The source IP address of the query must match an access-control rule.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the P4 tutorial application (org.onosproject.p4tutorial), the host event listener does not handle the following event types: HOST_MOVED, HOST_REMOVED, HOST_UPDATED. In combination with other applications, this could lead to the absence of intended code execution.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the virtual broadband network gateway application (org.onosproject.virtualbng), the host event listener does not handle the following event types: HOST_MOVED, HOST_REMOVED, HOST_UPDATED. In combination with other applications, this could lead to the absence of intended code execution.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the mobility application (org.onosproject.mobility), the host event listener does not handle the following event types: HOST_ADDED, HOST_REMOVED, HOST_UPDATED. In combination with other applications, this could lead to the absence of intended code execution.
A vulnerability in the call-handling functionality of Session Initiation Protocol (SIP) Software for Cisco IP Phone 7800 Series and 8800 Series could allow an unauthenticated, remote attacker to cause an affected phone to reload unexpectedly, resulting in a temporary denial of service (DoS) condition. The vulnerability is due to incomplete error handling when XML data within a SIP packet is parsed. An attacker could exploit this vulnerability by sending a SIP packet that contains a malicious XML payload to an affected phone. A successful exploit could allow the attacker to cause the affected phone to reload unexpectedly, resulting in a temporary DoS condition.
go-merkledag implements the 'DAGService' interface and adds two ipld node types, Protobuf and Raw for the ipfs project. A `ProtoNode` may be modified in such a way as to cause various encode errors which will trigger a panic on common method calls that don't allow for error returns. A `ProtoNode` should only be able to encode to valid DAG-PB, attempting to encode invalid DAG-PB forms will result in an error from the codec. Manipulation of an existing (newly created or decoded) `ProtoNode` using the modifier methods did not account for certain states that would place the `ProtoNode` into an unencodeable form. Due to conformance with the [`github.com/ipfs/go-block-format#Block`](https://pkg.go.dev/github.com/ipfs/go-block-format#Block) and [`github.com/ipfs/go-ipld-format#Node`](https://pkg.go.dev/github.com/ipfs/go-ipld-format#Node) interfaces, certain methods, which internally require a re-encode if state has changed, will panic due to the inability to return an error. This issue has been addressed across a number of pull requests. Users are advised to upgrade to version 0.8.1 for a complete set of fixes. Users unable to upgrade may attempt to mitigate this issue by sanitising inputs when allowing user-input to set a new `CidBuilder` on a `ProtoNode` and by sanitising `Tsize` (`Link#Size`) values such that they are a reasonable byte-size for sub-DAGs where derived from user-input.
An issue was discovered in Open Network Operating System (ONOS) 1.14. In the Ethernet VPN application (org.onosproject.evpnopenflow), the host event listener does not handle the following event types: HOST_MOVED, HOST_UPDATED. In combination with other applications, this could lead to the absence of intended code execution.
Advantech WebAccess/HMI Designer 2.1.9.31 has Exception Handler Chain corruption starting at Unknown Symbol @ 0x0000000000000000 called from ntdll!RtlRaiseStatus+0x00000000000000b4.
An error-handling flaw was found in python-ecdsa before version 0.13.3. During signature decoding, malformed DER signatures could raise unexpected exceptions (or no exceptions at all), which could lead to a denial of service.
quic-go is an implementation of the QUIC protocol in Go. The loss recovery logic for path probe packets that was added in the v0.50.0 release can be used to trigger a nil-pointer dereference by a malicious QUIC client. In order to do so, the attacker first sends valid QUIC packets from different remote addresses (thereby triggering the newly added path validation logic: the server sends path probe packets), and then sending ACKs for packets received from the server specifically crafted to trigger the nil-pointer dereference. v0.50.1 contains a patch that fixes the vulnerability. This release contains a test that generates random sequences of sent packets (both regular and path probe packets), that was used to verify that the patch actually covers all corner cases. No known workarounds are available.
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
A flaw was found in the Ceph RGW configuration with Beast as the front end handling client requests. An unauthenticated attacker could crash the Ceph RGW server by sending valid HTTP headers and terminating the connection, resulting in a remote denial of service for Ceph RGW clients.
decompress_gunzip.c in BusyBox through 1.32.1 mishandles the error bit on the huft_build result pointer, with a resultant invalid free or segmentation fault, via malformed gzip data.
The flowd process, responsible for forwarding traffic in SRX Series services gateways, may crash and restart when processing specific transit IP packets through an IPSec tunnel. Continued processing of these packets may result in an extended Denial of Service (DoS) condition. This issue only occurs when IPSec tunnels are configured. Systems without IPSec tunnel configurations are not vulnerable to this issue. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D171, 15.1X49-D180 on SRX Series; 18.2 versions 18.2R2-S1 and later, prior to 18.2R3 on SRX Series; 18.4 versions prior to 18.4R2 on SRX Series.
In Apache Subversion versions up to and including 1.9.10, 1.10.4, 1.12.0, Subversion's svnserve server process may exit when a client sends certain sequences of protocol commands. This can lead to disruption for users of the server.
SSL-Proxy feature on SRX devices fails to handle a hardware resource limitation which can be exploited by remote SSL/TLS servers to crash the flowd daemon. Repeated crashes of the flowd daemon can result in an extended denial of service condition. For this issue to occur, clients protected by the SRX device must initiate a connection to the malicious server. This issue affects: Juniper Networks Junos OS on SRX5000 Series: 12.3X48 versions prior to 12.3X48-D85; 15.1X49 versions prior to 15.1X49-D180; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S8; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R2.
@fastify/websocket provides WebSocket support for Fastify. Any application using @fastify/websocket could crash if a specific, malformed packet is sent. All versions of fastify-websocket are also impacted. That module is deprecated, so it will not be patched. This has been patched in version 7.1.1 (fastify v4) and version 5.0.1 (fastify v3). There are currently no known workarounds. However, it should be possible to attach the error handler manually. The recommended path is upgrading to the patched versions.
Traefik (pronounced traffic) is a modern HTTP reverse proxy and load balancer that assists in deploying microservices. There is a potential vulnerability in Traefik managing HTTP/2 connections. A closing HTTP/2 server connection could hang forever because of a subsequent fatal error. This failure mode could be exploited to cause a denial of service. There has been a patch released in versions 2.8.8 and 2.9.0-rc5. There are currently no known workarounds.