There are several endpoints in the Store Locator Plus for WordPress plugin through 5.5.15 that could allow unauthenticated attackers the ability to inject malicious JavaScript into pages.
Cross-site scripting (XSS) vulnerability in wordpress_sentinel.php in the Sentinel plugin 1.0.0 for WordPress allows remote attackers to inject arbitrary web script or HTML via unknown vectors.
OX App Suite through 7.10.4 allows XSS via an appointment in which the location contains JavaScript code.
OX App Suite through 7.10.4 allows XSS via JavaScript in a Note referenced by a mail:// URL.
All versions of package react-bootstrap-table are vulnerable to Cross-site Scripting (XSS) via the dataFormat parameter. The problem is triggered when an invalid React element is returned, leading to dangerouslySetInnerHTML being used, which does not sanitize the output.
An improper neutralization of input during web page generation in FortiWeb GUI interface 6.3.0 through 6.3.7 and version before 6.2.4 may allow an unauthenticated, remote attacker to perform a reflected cross site scripting attack (XSS) by injecting malicious payload in different vulnerable API end-points.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `statsBreakdown` parameter of stats.php (and possibly other scripts) due to single quotes not being escaped. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and pressing a certain key combination to execute injected JavaScript code.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
A XSS Vulnerability in Action View tag helpers >= 5.2.0 and < 5.2.0 which would allow an attacker to inject content if able to control input into specific attributes.
Cross-site scripting (XSS) vulnerability in admin.php in Phorum 5.2.18 allows remote attackers to inject arbitrary web script or HTML via the PATH_INFO to admin/index.php. NOTE: some of these details are obtained from third party information.
Cross-site scripting (XSS) vulnerability in pretty-bar.php in Pretty Link Lite plugin before 1.5.4 for WordPress allows remote attackers to inject arbitrary web script or HTML via the slug parameter, a different vulnerability than CVE-2011-5192.
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in userlog-index.php via the `period_preset` parameter.
VMware Workspace one UEM console (2102 prior to 21.2.0.8, 2101 prior to 21.1.0.14, 2011 prior to 20.11.0.27, 2010 prior to 20.10.0.16,2008 prior to 20.8.0.28, 2007 prior to 20.7.0.14,2006 prior to 20.6.0.19, 2005 prior to 20.5.0.46, 2004 prior to 20.4.0.21, 2003 prior to 20.3.0.23, 2001 prior to 20.1.0.32, 1912 prior to 19.12.0.24) contain a cross-site scripting vulnerability. VMware Workspace ONE UEM console does not validate incoming requests during device enrollment after leading to rendering of unsanitized input on the user device in response.
UserExcelOut.asp within WebAccess/SCADA is vulnerable to cross-site scripting (XSS), which could allow an attacker to send malicious JavaScript code. This could result in hijacking of cookie/session tokens, redirection to a malicious webpage, and unintended browser action on the WebAccess/SCADA (WebAccess/SCADA versions prior to 8.4.5, WebAccess/SCADA versions prior to 9.0.1).
Rocket.Chat before 3.11, 3.10.5, 3.9.7, 3.8.8 is vulnerable to persistent cross-site scripting (XSS) using nested markdown tags allowing a remote attacker to inject arbitrary JavaScript in a message. This flaw leads to arbitrary file read and RCE on Rocket.Chat desktop app.
A reflected cross-site script vulnerability in GitLab before versions 13.11.6, 13.12.6 and 14.0.2 allowed an attacker to send a malicious link to a victim and trigger actions on their behalf if they clicked it
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Multiple cross-site scripting (XSS) vulnerabilities in Dolibarr 3.1.0 RC and probably earlier allow remote attackers to inject arbitrary web script or HTML via the PATH_INFO to (1) index.php, (2) admin/boxes.php, (3) comm/clients.php, (4) commande/index.php; and the optioncss parameter to (5) admin/ihm.php and (6) user/home.php.
Multiple cross-site scripting (XSS) vulnerabilities in BugFree 2.1.3 allow remote attackers to inject arbitrary web script or HTML via (1) the ActionType parameter to Bug.php, the ReportMode parameter to (2) Report.php or (3) ReportLeft.php, or the PATH_INFO to (4) AdminProjectList.php, (5) AdminGroupList.php, or (6) AdminUserLogList.php.
Bad validation logic in the Dart SDK versions prior to 2.12.3 allow an attacker to use an XSS attack via DOM clobbering. The validation logic in dart:html for creating DOM nodes from text did not sanitize properly when it came across template tags.
Reflected XSS vulnerability in Micro Focus Application Automation Tools Plugin - Jenkins plugin. The vulnerability affects all version 6.7 and earlier versions.
A vulnerability in Pulse Connect Secure before 9.1R12 could allow a threat actor to perform a cross-site script attack against an authenticated administrator via an unsanitized web parameter.
An issue was discovered in Edimax EW-7438RPn Mini v2 before version 1.26. There is XSS in an SSID field.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
Multiple cross-site scripting (XSS) vulnerabilities in the server in Cisco Unified MeetingPlace 7.0 allow remote attackers to inject arbitrary web script or HTML via unspecified parameters, aka Bug IDs CSCuc65411 and CSCue18706.
Cross-site scripting (XSS) vulnerability in PHP Handicapper allows remote attackers to inject arbitrary web script or HTML via the msg parameter to msg.php. NOTE: some sources identify a second vector in the login parameter to process_signup.php, but the original source says that it is for CRLF injection (CVE-2005-4712). Also note: the vendor has disputed CVE-2005-3497, and it is possible that the dispute was intended to include this issue as well. If so, followup investigation strongly suggests that the original report is correct.
Revive Adserver before 5.1.0 is vulnerable to a reflected cross-site scripting (XSS) vulnerability via the publicly accessible afr.php delivery script. While this issue was previously addressed in modern browsers as CVE-2020-8115, some older browsers (e.g., IE10) that do not automatically URL encode parameters were still vulnerable.
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Cross-site scripting (XSS) vulnerability in post_alert.php in Alert Before Your Post plugin, possibly 0.1.1 and earlier, for WordPress allows remote attackers to inject arbitrary web script or HTML via the name parameter.
A cross-site scripting (XSS) vulnerability at /admin/goods/update in Newbee-Mall v1.0.0 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the goodsName parameter.
Client-Side code injection through Feature Flag name in GitLab CE/EE starting with 11.9 allows a specially crafted feature flag name to PUT requests on behalf of other users via clicking on a link
Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.11.1 allows stored XSS.
Multiple cross-site scripting (XSS) vulnerabilities in CosmoShop ePRO 10.05.00 allow remote attackers to inject arbitrary web script or HTML via (1) the rcopy parameter to cgi-bin/admin/rubrikadmin.cgi, (2) the typ parameter to cgi-bin/admin/artikeladmin.cgi, or (3) the suchbegriff parameter to cgi-bin/admin/shophilfe_suche.cgi.
Maccms v10 was discovered to contain a reflected cross-site scripting (XSS) vulnerability in /admin.php/admin/ulog/index.html via the wd parameter.
Multiple cross-site scripting (XSS) vulnerabilities in the Sodahead Polls plugin before 2.0.4 for WordPress allow remote attackers to inject arbitrary web script or HTML via (1) the poll_id parameter to customizer.php or (2) the customize parameter to poll.php.
Multiple cross-site scripting (XSS) vulnerabilities in HP Network Node Manager i 9.10 allow remote attackers to inject arbitrary web script or HTML via the (1) node parameter to nnm/mibdiscover; (2) nodename parameter to nnm/protected/configurationpoll.jsp, (3) nnm/protected/ping.jsp, (4) nnm/protected/statuspoll.jsp, or (5) nnm/protected/traceroute.jsp; or (6) field parameter to nmm/validate. NOTE: this might be a duplicate of CVE-2011-4155 or CVE-2011-4156.
Multiple cross-site scripting (XSS) vulnerabilities in admin/configuration.php in Geeklog before 1.7.1sr1 allow remote attackers to inject arbitrary web script or HTML via the (1) subgroup or (2) conf_group parameters. NOTE: this vulnerability might require a user-assisted attack or a bypass of a CSRF protection mechanism.
Cross-site scripting (XSS) vulnerability in notes.php in Rapidleech before 2.3 rev42 SVN r399 allows remote attackers to inject arbitrary web script or HTML via the notes parameter.
On BIG-IP versions 16.0.x before 16.0.1.1, 15.1.x before 15.1.2.1, 14.1.x before 14.1.4, 13.1.x before 13.1.3.6, 12.1.x before 12.1.5.3, and 11.6.x before 11.6.5.3, undisclosed endpoints in iControl REST allow for a reflected XSS attack, which could lead to a complete compromise of the BIG-IP system if the victim user is granted the admin role. This vulnerability is due to an incomplete fix for CVE-2020-5948. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
Multiple cross-site scripting (XSS) vulnerabilities in includes/templates/template_default/common/tpl_header_test_info.php in Zen Cart 1.3.9h, when debugging is enabled, might allow remote attackers to inject arbitrary web script or HTML via the (1) main_page parameter or (2) PATH_INFO, a different vulnerability than CVE-2011-4567.
The XrayWrapper implementation in Mozilla Firefox before 23.0 and SeaMonkey before 2.20 does not properly address the possibility of an XBL scope bypass resulting from non-native arguments in XBL function calls, which makes it easier for remote attackers to conduct cross-site scripting (XSS) attacks by leveraging access to an unprivileged object.
Cross-site scripting (XSS) vulnerability in tiki-view_forum_thread.php in TikiWiki 1.9.0 through 1.9.2 allows remote attackers to inject arbitrary web script or HTML via the topics_offset parameter.
Revive Adserver before v5.2.0 is vulnerable to a reflected XSS vulnerability in the `status` parameter of campaign-zone-zones.php. An attacker could trick a user with access to the user interface of a Revive Adserver instance into clicking on a specifically crafted URL and execute injected JavaScript code.
Multiple cross-site scripting (XSS) vulnerabilities in Infoproject Biznis Heroj allow remote attackers to inject arbitrary web script or HTML via the config parameter to (1) nalozi_naslov.php and (2) widget.dokumenti_lista.php.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Revive Adserver before 5.1.1 is vulnerable to a reflected XSS vulnerability in stats.php via the `setPerPage` parameter.
Barco Control Room Management Suite web application, which is part of TransForm N before 3.14, is exposing a license file upload mechanism. Lack of input sanitization of the upload mechanism is leads to stored XSS.
Cross-site scripting vulnerability exists in WP Statistics versions prior to 13.2.0 because it improperly processes a platform parameter. By exploiting this vulnerability, an arbitrary script may be executed on the web browser of the user who is logging in to the website using the product.
Cross-site scripting (XSS) vulnerability in sign.php in tinyguestbook allows remote attackers to inject arbitrary web script or HTML via the msg parameter.