Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-11766

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-19 May, 2020 | 19:27
Updated At-04 Aug, 2024 | 11:41
Rejected At-
Credits

sendfax.php in iFAX AvantFAX before 3.3.6 and HylaFAX Enterprise Web Interface before 0.2.5 allows authenticated Command Injection.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:19 May, 2020 | 19:27
Updated At:04 Aug, 2024 | 11:41
Rejected At:
▼CVE Numbering Authority (CNA)

sendfax.php in iFAX AvantFAX before 3.3.6 and HylaFAX Enterprise Web Interface before 0.2.5 allows authenticated Command Injection.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
ftp://ftp.ifax.com/security/CVE-2020-11766.html
x_refsource_CONFIRM
Hyperlink: ftp://ftp.ifax.com/security/CVE-2020-11766.html
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
ftp://ftp.ifax.com/security/CVE-2020-11766.html
x_refsource_CONFIRM
x_transferred
Hyperlink: ftp://ftp.ifax.com/security/CVE-2020-11766.html
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:19 May, 2020 | 20:15
Updated At:21 Jul, 2021 | 11:39

sendfax.php in iFAX AvantFAX before 3.3.6 and HylaFAX Enterprise Web Interface before 0.2.5 allows authenticated Command Injection.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

ifax
ifax
>>hylafax>>Versions from 0.2.0(inclusive) to 0.2.5(exclusive)
cpe:2.3:a:ifax:hylafax:*:*:*:*:enterprise:*:*:*
avantfax
avantfax
>>avantfax>>Versions from 3.3.0(inclusive) to 3.3.6(exclusive)
cpe:2.3:a:avantfax:avantfax:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
ftp://ftp.ifax.com/security/CVE-2020-11766.htmlcve@mitre.org
Vendor Advisory
Hyperlink: ftp://ftp.ifax.com/security/CVE-2020-11766.html
Source: cve@mitre.org
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1047Records found

CVE-2010-3753
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.65% / 69.87%
||
7 Day CHG~0.00%
Published-05 Oct, 2010 | 21:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

programs/pluto/xauth.c in the client in Openswan 2.6.26 through 2.6.28 allows remote authenticated gateways to execute arbitrary commands via shell metacharacters in the cisco_banner (aka server_banner) field, a different vulnerability than CVE-2010-3308.

Action-Not Available
Vendor-xelerancen/a
Product-openswann/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.58%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7407
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.00% / 76.07%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 13:32
Updated-16 Jul, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear D6400 diag.cgi os command injection

A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-d6400d6400_firmwareD6400
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6899
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.06%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:32
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+/DI-8200G msp_info.htm os command injection

A vulnerability, which was classified as critical, was found in D-Link DI-7300G+ and DI-8200G 17.12.20A1/19.12.25A1. This affects an unknown part of the file msp_info.htm. The manipulation of the argument flag/cmd/iface leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-8200gdi-8200g_firmwaredi-7300g\+DI-8200GDI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-12246
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.58% / 88.80%
||
7 Day CHG~0.00%
Published-29 Apr, 2020 | 12:34
Updated-04 Aug, 2024 | 11:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Beeline Smart Box 2.0.38 routers allow "Advanced settings > Other > Diagnostics" OS command injection via the Ping ping_ipaddr parameter, the Nslookup nslookup_ipaddr parameter, or the Traceroute traceroute_ipaddr parameter.

Action-Not Available
Vendor-beelinen/a
Product-smart_box_firmwaresmart_boxn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11950
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.47% / 80.10%
||
7 Day CHG~0.00%
Published-28 May, 2020 | 12:44
Updated-04 Aug, 2024 | 11:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). For example, this affects IT9388-HT devices.

Action-Not Available
Vendor-vivotekn/a
Product-ib8382-rt_firmwareib8379-hfd8177-ht_firmwarefe9582-ehnvfd9387-htvfe9180-hfd8167a-sib9388-htfd9367-ehtv_firmwareib9389-ht_firmwarefd9387-ehvib9381-\(e\)ht_firmwarefd9387-hvcd8371-hnvf2fd9388-htv_firmwareib836b-hf3fd9371-\(e\)htvsd9362-ehfd9381-\(e\)htv_firmwarefd8369a-v_firmwareip9191-hp_firmwarefd9165-ht-aib9367-htfd8379-hv_firmwaresd9366-ehfd9391-ehtvfd8167a-s_firmwarefd836b-htv_firmwarefd9365-ehtv_firmwaresd9363-ehl_firmwarefd9187-ht_firmwareit9389-hmd8563-dehfd9368-htv_firmwarefd9380-hfd9189-hm_firmwarefd9365-ehtv-a_firmwarefe9391-ev_firmwareib9365-htib8382-et_firmwarefd9189-hfd8177-hfd9365-htvl_firmwarefd9389-hmvfd9389-ehmv_firmwarefd816ca-hf2cc8160\(hs\)_firmwareib9381-\(e\)htfd9167-htfd9365-htv-a_firmwareib836ba-hf3_firmwareib8377-htfe9391-evfd9366-hv_firmwareib9391-eht_firmwaresd9364-ehib9389-ehm_firmwarefd9367-htv\(epoc\)ib9365-ht-a_firmwarefd8182-t_firmwarefd9171-htit9388-ht_firmwarefd9365-htv-afd8382-etv_firmwareip9165-lpcib9389-ehmmd8563-ehib9387-h_firmwarefd836b-htvib9387-eht-afd8377-htv_firmwaresd9362-eh-v2_firmwarefe9191ib8382-f3fd8182-f2ib9387-ht-a_firmwarevc8101_firmwarefd8369a-vit9360-h_firmwarefd9360-hfd8179-hib9387-ht-afd8382-tvip8160_firmwareip8160-wfd9187-ht-ama9321-ehtv_firmwarefd816ba-ht_firmwareib8360ib8360-wfd836ba-hvf2fe9382-ehv_firmwarevs8100-v2_firmwarefe9182-h_firmwaremd9560-dhib8382-ef3fd8182-f1fe9182-hfd9166-hn_firmwaremd9560-hib9389-hib9387-hib8360-w_firmwaremd9561-h_firmwarefd8166a-n_firmwarecd8371-hntv_firmwarecc9381-hv_firmwareib836ba-ht_firmwaresd9362-ehlmd9561-hfd9365-htvsd9363-ehl-v2_firmwarefd8377-ehtv_firmwaremd8564-ehfd9391-ehtv_firmwarefd9387-ehv_firmwareip9165-hpip8166fd9367-hv_firmwareib836ba-htcc8160_firmwareib836b-hf3_firmwarefd9389-hv_firmwarefd8382-vf2_firmwareip9167-hp_firmwarefd9187-hip9191-hpib8360_firmwaretb9330-eib8382-rf3fe9382-ehvfd836b-ehvf2_firmwareit9360-hip9167-hpfd9365-htvlib9371-\(e\)htib8382-ef3_firmwareib8369afd9367-hvib9367-h_firmwarefd9181-ht_firmwarefe9191_firmwareib836b-ehf3_firmwarecd8371-hntvib8382-rf3_firmwareip9164-lpc_firmwareib8377-hfd816b-hf2md8565-n_firmwareip9171-hp_firmwareib8369a_firmwarefd8179-h_firmwarefd9187-ht-a_firmwarecc9381-hvsd9364-ehl-v2_firmwareib9389-ehtfd816b-hf2_firmwareib9371-\(e\)ht_firmwareip9164-htit9389-ht_firmwareib8367acc8160\(hs\)fd8382-tv_firmwareip8160cc8371-hvsd9364-eh-v2ib9389-h_firmwaresd9362-eh_firmwarems9321-ehvib836b-htib836ba-ehf3_firmwarefd8382-evf2fd836ba-ehvf2fd816c-hf2_firmwarefd9389-ehmviz9361-eh_firmwareib9387-eht_firmwareib9387-ehtfd9389-ehvib9360-h_firmwarefd9365-htv_firmwaresd9365-ehl_firmwarefd8177-htib8382-f3_firmwaresd9374-ehl\(x\)ib9367-ht_firmwarefd9388-htvfd9167-h_firmwarevc8101ib8382-rtip9165-lpc_firmwareib836b-ht_firmwareib836b-eht_firmwaresd9366-eh_firmwareib9368-htfe9180-h_firmwarefd9181-htfd9389-htvib9389-eht_firmwaresd9364-eh-v2_firmwarefd836ba-hvf2_firmwarefd9371-\(e\)htv_firmwareib8377-ht_firmwarefd9165-htfd8182-f2_firmwareip9167-htfd9167-hfd8167afd836b-hvf2ip9164-ht_firmwareib9367-ehtfd9368-htvfe9381-ehvib9387-ht_firmwarefd9171-ht_firmwarefd9387-ehtvfd816ba-hf2fd8182-f1_firmwarems9321-ehv_firmwareit9380-hfd9387-htv-afd8367a-v_firmwarefd836ba-ehtvfd9189-h_firmwaresd9361-ehl_firmwarefd8382-vf2ip9172-lpc_firmwarems9390-hvib836b-ehtib9387-ehfd9360-h_firmwareip9181-h_firmwarefd836ba-htvfd9387-ehtv-acc8370-hvfd9380-h_firmwareib9365-eht_firmwareib836b-hrf3_firmwarefd9366-hvib8382-t_firmwaresd9366-eh-v2_firmwaremd9560-h_firmwaremd9560-dh_firmwarefd9166-hnsd9374-ehl\(x\)_firmwareib8367a_firmwarefd9387-htv_firmwarecc8371-hv_firmwarema9322-ehtv_firmwareib9365-eht-a_firmwarefd9187-h_firmwarefd816ca-hf2_firmwarefd9167-ht_firmwareip9181-hfd8382-evf2_firmwaremd8564-eh_firmwaremd9581-h_firmwareip9191-htsd9366-eh-v2ip9167-ht_firmwarefd8177-h_firmwarefd816b-ht_firmwarefd8366-vip9165-htib836b-ehf3fd8166a-nfe9181-h_firmwareib9389-ehib9367-eh_firmwarefd836b-ehtv_firmwarefd9387-ehtv_firmwaretb9331-efd816ba-htsd9365-ehlfe9181-hfd836ba-htv_firmwarefd9389-ehv_firmwaresd9361-ehlib836b-hrf3ib9365-ht_firmwareip9164-lpcfd9165-ht_firmwareib9367-ehsd9362-eh-v2ib9391-ehtib9367-hfd8377-ehtvit9380-h_firmwareib8377-eht_firmwarefd8169a_firmwareib836ba-hf3fe8182fd836ba-ehvf2_firmwarefe9380-hv_firmwarefd8166aip9165-hp_firmwarefd9367-ehtvib9389-hm_firmwareib8377-ehtib9365-eht-aib8382-etcc8370-hv_firmwareip9172-lpcfd8169a-s_firmwareib9387-htib9365-ht-aip9191-ht_firmwarefe9380-hvfe9582-ehnv_firmwarefd9367-htv\(epoc\)_firmwaresd9364-ehl_firmwarefe8182_firmwaremd8563-deh_firmwarema9322-ehtvtb9331-e_firmwareit9389-h_firmwarefd816c-hf2fd9165-ht-a_firmwareib9380-h_firmwaresd9363-ehl-v2ib9365-ehtfd9381-\(e\)htvmd8565-nib836ba-ehtfd9367-htv_firmwareip8160-w_firmwarefd9189-hmfd8377-hvib9389-eh_firmwareib836ba-eht_firmwareip9165-lpc\(i-cs_kit\)ib8382-tfd9389-ehtv_firmwarefd8169aib9368-ht_firmwarefd8167a_firmwaresd9364-ehlcd8371-hnvf2_firmwareit9389-htsd9364-ehl-v2fd836b-ehvf2fd9367-htvfd8366-v_firmwareib9388-ht_firmwareip8166_firmwareip9171-hpib8377-h_firmwarefd816ba-hf2_firmwarefd836b-hvf2_firmwarefd816b-htmd9581-hmd8563-eh_firmwarefd9387-ehtv-a_firmwaresd9366-ehlfd8166a_firmwareip9165-ht_firmwarefd8182-tfd9365-ehtvms9390-hv_firmwarefe9381-ehv_firmwareip9165-lpc\(i-cs_kit\)_firmwarefd8377-htvfd9389-ehtvfd9189-ht_firmwareib9387-eh_firmwareit9388-htib9360-hfd8367a-vcc8160vs8100-v2sd9161-hfd9187-htfd9389-hvfd8169a-ssd9362-ehl_firmwareib9380-htb9330-e_firmwarefd8382-etvma9321-ehtvsd9363-ehlsd9364-eh_firmwarefd836b-ehtvib9389-htib836ba-ehf3ib9389-hmib9387-eht-a_firmwareiz9361-ehsd9366-ehl_firmwarefd8379-hvfd8377-hv_firmwarefd9389-hmv_firmwarefd9387-htv-a_firmwareib9367-eht_firmwarefd836ba-ehtv_firmwarefd9389-htv_firmwareib8379-h_firmwarefd9189-htsd9161-h_firmwarefd9365-ehtv-afd9387-hv_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 70.86%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 13:32
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formSetWanStatic os command injection

A vulnerability has been found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this vulnerability is the function formSetWanStatic of the file /goform/formSetWanStatic of the component webs. The manipulation of the argument m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 is directly passed by the attacker/so we can control the m_wan_ipaddr/m_wan_netmask/m_wan_gateway/m_wan_staticdns1/m_wan_staticdns2 leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-12078
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-63.67% / 98.34%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 13:26
Updated-04 Aug, 2024 | 11:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Open-AudIT 3.3.1. There is shell metacharacter injection via attributes to an open-audit/configuration/ URI. An attacker can exploit this by adding an excluded IP address to the global discovery settings (internally called exclude_ip). This exclude_ip value is passed to the exec function in the discoveries_helper.php file (inside the all_ip_list function) without being filtered, which means that the attacker can provide a payload instead of a valid IP address.

Action-Not Available
Vendor-opmantekn/a
Product-open-auditn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.28%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7082
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.69% / 70.86%
||
7 Day CHG~0.00%
Published-06 Jul, 2025 | 14:02
Updated-09 Jul, 2025 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1122 webs formBSSetSitesurvey os command injection

A vulnerability was found in Belkin F9K1122 1.00.33 and classified as critical. Affected by this issue is the function formBSSetSitesurvey of the file /goform/formBSSetSitesurvey of the component webs. The manipulation of the argument wan_ipaddr/wan_netmask/wan_gateway/wl_ssid is directly passed by the attacker/so we can control the wan_ipaddr/wan_netmask/wan_gateway/wl_ssid leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1122f9k1122_firmwareF9K1122
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7154
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.67% / 85.22%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 00:32
Updated-16 Jul, 2025 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N200RE cstecgi.cgi sub_41A0F8 os command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK N200RE 9.3.5u.6095_B20200916/9.3.5u.6139_B20201216. Affected by this issue is the function sub_41A0F8 of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n200ren200re_firmwareN200RE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11953
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.85% / 73.91%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:02
Updated-04 Aug, 2024 | 11:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code.

Action-Not Available
Vendor-rittaln/a
Product-cmciii-pu-9333e0fb_firmwarepdu-3c002dec_firmwareiot_interface_3124.300lcp-cw_firmwarecmc_iii_pu_7030.000_firmwarecmciii-pu-9333e0fbpdu-3c002declcp-cwcmc_iii_pu_7030.000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-12111
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.51% / 88.70%
||
7 Day CHG~0.00%
Published-04 May, 2020 | 14:05
Updated-04 Aug, 2024 | 11:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain TP-Link devices allow Command Injection. This affects NC260 1.5.2 build 200304 and NC450 1.5.3 build 200304.

Action-Not Available
Vendor-n/aTP-Link Systems Inc.
Product-nc260_firmwarenc450_firmwarenc260nc450n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6485
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-10.93% / 93.13%
||
7 Day CHG-1.43%
Published-22 Jun, 2025 | 17:00
Updated-14 Aug, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3002R formWlSiteSurvey os command injection

A vulnerability was found in TOTOLINK A3002R 1.1.1-B20200824.0128. It has been classified as critical. This affects the function formWlSiteSurvey of the file /boafrm/formWlSiteSurvey. The manipulation of the argument wlanif leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a3002r_firmwarea3002rA3002R
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6618
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE wps.so SetWLanApcliSettings os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been classified as critical. Affected is the function SetWLanApcliSettings of the file wps.so. The manipulation of the argument PIN leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11699
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-16.88% / 94.69%
||
7 Day CHG~0.00%
Published-17 Sep, 2020 | 16:31
Updated-04 Aug, 2024 | 11:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Titan SpamTitan 7.07. Improper validation of the parameter fname on the page certs-x.php would allow an attacker to execute remote code on the target server. The user has to be authenticated before interacting with this page.

Action-Not Available
Vendor-titanhqn/a
Product-spamtitann/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6104
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.45%
||
7 Day CHG-0.03%
Published-16 Jun, 2025 | 03:31
Updated-16 Jun, 2025 | 18:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wifi-soft UniBox Controller pms_check.php os command injection

A vulnerability, which was classified as critical, was found in Wifi-soft UniBox Controller up to 20250506. This affects an unknown part of the file /billing/pms_check.php. The manipulation of the argument ipaddress leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Wifi-soft
Product-UniBox Controller
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6619
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE upgrade.so setUpgradeFW os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been declared as critical. Affected by this vulnerability is the function setUpgradeFW of the file upgrade.so. The manipulation of the argument FileName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11016
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.1||CRITICAL
EPSS-1.37% / 79.43%
||
7 Day CHG~0.00%
Published-30 Apr, 2020 | 22:25
Updated-04 Aug, 2024 | 11:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Remote code execution in Message sending functionality in IntelMQ Manager

IntelMQ Manager from version 1.1.0 and before version 2.1.1 has a vulnerability where the backend incorrectly handled messages given by user-input in the "send" functionality of the Inspect-tool of the Monitor component. An attacker with access to the IntelMQ Manager could possibly use this issue to execute arbitrary code with the privileges of the webserver. Version 2.1.1 fixes the vulnerability.

Action-Not Available
Vendor-intelmq_manager_projectcerttools
Product-intelmq_managerIntelMQ Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6562
Matching Score-4
Assigner-TWCERT/CC
ShareView Details
Matching Score-4
Assigner-TWCERT/CC
CVSS Score-8.7||HIGH
EPSS-0.48% / 64.29%
||
7 Day CHG~0.00%
Published-26 Jun, 2025 | 12:12
Updated-26 Jun, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Hunt Electronic Hybrid DVR - OS Command Injection

Certain hybrid DVR models (HBF-09KD and HBF-16NK) from Hunt Electronic have an OS Command Injection vulnerability, allowing remote attackers with regular privileges to inject arbitrary OS commands and execute them on the device.

Action-Not Available
Vendor-Hunt Electronic
Product-Hybrid DVR
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23667
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-1.26% / 78.60%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 20:08
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6102
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.37% / 58.00%
||
7 Day CHG-0.05%
Published-16 Jun, 2025 | 02:31
Updated-16 Jun, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wifi-soft UniBox Controller logout.php os command injection

A vulnerability classified as critical was found in Wifi-soft UniBox Controller up to 20250506. Affected by this vulnerability is an unknown functionality of the file /authentication/logout.php. The manipulation of the argument mac_address leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Wifi-soft
Product-UniBox Controller
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10818
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-7.56% / 91.46%
||
7 Day CHG~0.00%
Published-22 Mar, 2020 | 19:53
Updated-04 Aug, 2024 | 11:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Artica Proxy 4.26 allows remote command execution for an authenticated user via shell metacharacters in the "Modify the hostname" field.

Action-Not Available
Vendor-n/aArtica Tech SARL
Product-artica_proxyn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10808
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-86.47% / 99.37%
||
7 Day CHG~0.00%
Published-22 Mar, 2020 | 16:07
Updated-04 Aug, 2024 | 11:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vesta Control Panel (VestaCP) through 0.9.8-26 allows Command Injection via the schedule/backup Backup Listing Endpoint. The attacker must be able to create a crafted filename on the server, as demonstrated by an FTP session that renames .bash_logout to a .bash_logout' substring followed by shell metacharacters.

Action-Not Available
Vendor-vestacpn/a
Product-vesta_control_paneln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10221
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-91.06% / 99.63%
||
7 Day CHG~0.00%
Published-08 Mar, 2020 | 21:03
Updated-30 Jul, 2025 | 01:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-03||Apply updates per vendor instructions.

lib/ajaxHandlers/ajaxAddTemplate.php in rConfig through 3.94 allows remote attackers to execute arbitrary OS commands via shell metacharacters in the fileName POST parameter.

Action-Not Available
Vendor-rconfign/arConfig
Product-rconfign/arConfig
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10603
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.39% / 58.97%
||
7 Day CHG~0.00%
Published-09 Apr, 2020 | 13:10
Updated-04 Aug, 2024 | 11:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

WebAccess/NMS (versions prior to 3.0.2) does not properly sanitize user input and may allow an attacker to inject system commands remotely.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccess\/nmsWebAccess/NMS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:31
Updated-10 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkFWByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this issue is the function RP_checkFWByBBS of the file /goform/RP_checkFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.13%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.73%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.46%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.23%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5441
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.64%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10390
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-4.70% / 88.94%
||
7 Day CHG~0.00%
Published-12 Mar, 2020 | 13:03
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OS Command Injection in export.php (vulnerable function called from include/functions-article.php) in Chadha PHPKB Standard Multi-Language 9 allows remote attackers to achieve Code Execution by saving the code to be executed as the wkhtmltopdf path via admin/save-settings.php.

Action-Not Available
Vendor-chadhaajayn/a
Product-phpkbn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5444
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.24%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10213
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.55% / 88.76%
||
7 Day CHG~0.00%
Published-07 Mar, 2020 | 00:29
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the wps_sta_enrollee_pin parameter in a set_sta_enrollee_pin.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.

Action-Not Available
Vendor-n/aTRENDnet, Inc.D-Link Corporation
Product-tew-632brpdir-825_firmwaredir-825tew-632brp_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10216
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.58% / 88.81%
||
7 Day CHG~0.00%
Published-07 Mar, 2020 | 00:29
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the date parameter in a system_time.cgi POST request. TRENDnet TEW-632BRP 1.010B32 is also affected.

Action-Not Available
Vendor-n/aTRENDnet, Inc.D-Link Corporation
Product-tew-632brpdir-825_firmwaredir-825tew-632brp_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10173
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-65.18% / 98.41%
||
7 Day CHG~0.00%
Published-05 Mar, 2020 | 14:36
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Comtrend VR-3033 DE11-416SSG-C01_R02.A2pvI042j1.d26m devices have Multiple Authenticated Command Injection vulnerabilities via the ping and traceroute diagnostic pages, as demonstrated by shell metacharacters in the pingIpAddress parameter to ping.cgi.

Action-Not Available
Vendor-comtrendn/a
Product-vr-3033vr-3033_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10583
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.36% / 84.30%
||
7 Day CHG~0.00%
Published-25 Mar, 2021 | 19:47
Updated-04 Aug, 2024 | 11:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The /admin/admapi.php script of Invigo Automatic Device Management (ADM) through 5.0 allows remote authenticated attackers to execute arbitrary OS commands on the server as the user running the application.

Action-Not Available
Vendor-invigon/a
Product-automatic_device_managementn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-10235
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.70% / 71.07%
||
7 Day CHG~0.00%
Published-09 Mar, 2020 | 15:04
Updated-04 Aug, 2024 | 10:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Froxlor before 0.10.14. Remote attackers with access to the installation routine could have executed arbitrary code via the database configuration options that were passed unescaped to exec, because of _backupExistingDatabase in install/lib/class.FroxlorInstall.php.

Action-Not Available
Vendor-froxlorn/a
Product-froxlorn/a
CWE ID-CWE-116
Improper Encoding or Escaping of Output
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-9859
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.16%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 12:34
Updated-04 Aug, 2024 | 22:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vesta Control Panel (VestaCP) 0.9.7 through 0.9.8-23 is vulnerable to an authenticated command execution that can result in remote root access on the server. The platform works with PHP as the frontend language and uses shell scripts to execute system actions. PHP executes shell script through the dangerous command exec. This function can be dangerous if arguments passed to it are not filtered. Every user input in VestaCP that is used as an argument is filtered with the escapeshellarg function. This function comes from the PHP library directly and its description is as follows: "escapeshellarg() adds single quotes around a string and quotes/escapes any existing single quotes allowing you to pass a string directly to a shell function and having it be treated as a single safe argument." It means that if you give Username, it will have 'Username' as a replacement. This works well and protects users from exploiting this potentially dangerous exec function. Unfortunately, VestaCP uses this escapeshellarg function incorrectly in several places.

Action-Not Available
Vendor-vestacpn/a
Product-vesta_control_paneln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8314
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 80.55%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the system function with untrusted input from the request body for the SetQoSSettings API function, as demonstrated by shell metacharacters in the IPAddress field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-47709
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-9.1||CRITICAL
EPSS-0.29% / 52.32%
||
7 Day CHG~0.00%
Published-11 May, 2024 | 13:07
Updated-14 Jan, 2025 | 21:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
IBM Security Guardium command injection

IBM Security Guardium 11.3, 11.4, 11.5, and 12.0 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 271524.

Action-Not Available
Vendor-IBM Corporation
Product-security_guardiumSecurity Guardiumsecurity_guardium
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8316
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.53% / 80.59%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the system function with untrusted input from the request body for the SetWebFilterSettings API function, as demonstrated by shell metacharacters in the WebFilterURLs field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-8318
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.52% / 80.55%
||
7 Day CHG~0.00%
Published-13 Feb, 2019 | 03:00
Updated-16 Sep, 2024 | 19:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-878 devices with firmware 1.12A1. This issue is a Command Injection allowing a remote attacker to execute arbitrary code, and get a root shell. A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted /HNAP1 POST request. This occurs when any HNAP API function triggers a call to the twsystem function with untrusted input from the request body for the SetSysEmailSettings API function, as demonstrated by shell metacharacters in the SMTPServerPort field.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-39202
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.6||HIGH
EPSS-2.31% / 84.15%
||
7 Day CHG~0.00%
Published-08 Jul, 2024 | 00:00
Updated-02 Aug, 2024 | 04:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-823X firmware - 240126 was discovered to contain a remote command execution (RCE) vulnerability via the dhcpd_startip parameter at /goform/set_lan_settings.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823x_ax3000_firmwaredir-823x_ax3000n/adir-823x_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-20727
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.95% / 87.89%
||
7 Day CHG~0.00%
Published-17 Jan, 2019 | 02:00
Updated-05 Aug, 2024 | 12:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple command injection vulnerabilities in NeDi before 1.7Cp3 allow authenticated users to execute code on the server side via the flt parameter to Nodes-Traffic.php, the dv parameter to Devices-Graph.php, or the tit parameter to drawmap.php.

Action-Not Available
Vendor-nedin/a
Product-nedin/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-47560
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-7.4||HIGH
EPSS-0.49% / 64.56%
||
7 Day CHG~0.00%
Published-05 Jan, 2024 | 16:18
Updated-17 Jun, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
QuMagie

An OS command injection vulnerability has been reported to affect QuMagie. If exploited, the vulnerability could allow authenticated users to execute commands via a network. We have already fixed the vulnerability in the following version: QuMagie 2.2.1 and later

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-qumagieQuMagie
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-2234
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.9||CRITICAL
EPSS-2.01% / 82.96%
||
7 Day CHG-1.27%
Published-24 Aug, 2022 | 15:15
Updated-16 Apr, 2025 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mySCADA myPRO Command Injection

An authenticated mySCADA myPRO 8.26.0 user may be able to modify parameters to run commands directly in the operating system.

Action-Not Available
Vendor-myscadamySCADA Technologies
Product-mypromySCADA myPRO
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-47565
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-8||HIGH
EPSS-79.95% / 99.07%
||
7 Day CHG~0.00%
Published-08 Dec, 2023 | 16:06
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2024-01-11||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
Legacy VioStor NVR

An OS command injection vulnerability has been found to affect legacy QNAP VioStor NVR models running QVR Firmware 4.x. If exploited, the vulnerability could allow authenticated users to execute commands via a network. We have already fixed the vulnerability in the following versions: QVR Firmware 5.0.0 and later

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-qvr_firmwareVioStor NVRVioStor NVR
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 20
  • 21
  • Next
Details not found