MeterSphere is a one-stop open source continuous testing platform, covering functions such as test tracking, interface testing, UI testing and performance testing. The Selenium VNC config used in Metersphere is using a weak password by default, attackers can login to vnc and obtain high permissions. This issue has been addressed in version 2.10.7 LTS. Users are advised to upgrade. There are no known workarounds for this vulnerability.
D-Link DVX-2000MS contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values.
NPort IAW5000A-I/O Series firmware version v2.2 and prior is affected by a hardcoded credential vulnerabilitywhich poses a potential risk to the security and integrity of the affected device. This vulnerability is attributed to the presence of a hardcoded key, which could potentially facilitate firmware manipulation.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.
D-Link DVG-3104MS version 1.0.2.0.3, 1.0.2.0.4, and 1.0.2.0.4E contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
The installation script in Katello 1.0 and earlier does not properly generate the Application.config.secret_token value, which causes each default installation to have the same secret token, and allows remote attackers to authenticate to the CloudForms System Engine web interface as an arbitrary user by creating a cookie using the default secret_token.
A hard coded password in Super Store Finder v3.6 allows attackers to access the administration panel.
A privilege escalation vulnerability exists in the /bin/login functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted command line argument can lead to a limited-shell escape and elevated capabilities. An attacker can authenticate with hard-coded credentials and execute unblocked default busybox functionality to trigger this vulnerability.
NETSCOUT nGeniusPULSE 3.8 has a Hardcoded Cryptographic Key.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to gain administrative privileges to all UNI-NMS managed devices.
In ZKT ZKBio CVSecurity 6.4.1_R an unauthenticated attacker can craft JWT token using the hardcoded secret to authenticate to the service console. NOTE: the Supplier disputes the significance of this report because the service console is typically only accessible from a local area network, and because access to the service console does not result in login access or data access in the context of the application software platform.
N.V.K.INTER CO., LTD. (NVK) iBSG v3.5 was discovered to contain a hardcoded root password which allows attackers to login with root privileges via the SSH service.
The affected devices use publicly available default credentials with administrative privileges.
D-Link DPH-400S/SE VoIP Phone v1.01 contains hardcoded provisioning variables, including PROVIS_USER_PASSWORD, which may expose sensitive user credentials. An attacker with access to the firmware image can extract these credentials using static analysis tools such as strings or xxd, potentially leading to unauthorized access to device functions or user accounts. This vulnerability exists due to insecure storage of sensitive information in the firmware binary.
An issue in SCHUHFRIED v.8.22.00 allows remote attacker to obtain the database password via crafted curl command.
The /irmdata/api/ endpoints exposed by the IRM Next Generation booking engine authenticates requests using HMAC tokens. These tokens are however exposed in a JavaScript file loaded on the client side, thus rendering this extra safety mechanism useless.
Shenzhen Tuoshi NR500-EA RG500UEAABxCOMSLICv3.4.2731.16.43 devices enable the SSH service by default. There is a hidden hard-coded root account that cannot be disabled in the GUI.
SpotCam Co., Ltd. SpotCam FHD 2’s hidden Telnet function has a vulnerability of using hard-coded Telnet credentials. An remote unauthenticated attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
The CS5000 Fire Panel is vulnerable due to a hard-coded password that runs on a VNC server and is visible as a string in the binary responsible for running VNC. This password cannot be altered, allowing anyone with knowledge of it to gain remote access to the panel. Such access could enable an attacker to operate the panel remotely, potentially putting the fire panel into a non-functional state and causing serious safety issues.
SpotCam Co., Ltd. SpotCam FHD 2 has a vulnerability of using hard-coded uBoot credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service.
A use of hard-coded cryptographic key in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via crafted requests.
SmartSoft SmartBPM.NET has a vulnerability of using hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code and disrupt service.
Control ID IDSecure 4.7.26.0 and prior uses a hardcoded cryptographic key in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
JBL soundbar multibeam 5.1 - CWE-798: Use of Hard-coded Credentials
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
IBM Spectrum Virtualize 8.2, 8.3, and 8.4 could allow an attacker to allow unauthorized access due to the reuse of support generated credentials. IBM X-Force ID: 212609.
PiiGAB M-Bus contains hard-coded credentials which it uses for authentication.
Connected IO v2.1.0 and prior uses a hard-coded username/password pair embedded in their device's firmware used for device communication using MQTT. An attacker who gained access to these credentials is able to connect to the MQTT broker and send messages on behalf of devices, impersonating them. in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
ENENSYS IPGuard v2 2.10.0 was discovered to contain hardcoded credentials.
Draytek Vigor Routers firmware versions below 3.9.6/4.2.4, Access Points firmware versions below v1.4.0, Switches firmware versions below 2.6.7, and Myvigor firmware versions below 2.3.2 were discovered to use hardcoded encryption keys which allows attackers to bind any affected device to their own account. Attackers are then able to create WCF and DrayDDNS licenses and synchronize them from the website.
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 256016.
MXsecurity version 1.0 is vulnearble to hardcoded credential vulnerability. This vulnerability has been reported that can be exploited to craft arbitrary JWT tokens and subsequently bypass authentication for web-based APIs.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 contains multiple hard coded credentials for the Telnet and SSH interfaces.
AMI SPx contains a vulnerability in the BMC where an Attacker may cause a use of hard-coded cryptographic key by a hard-coded certificate. A successful exploit of this vulnerability may lead to a loss of confidentiality, integrity, and availability.
Synel SYnergy Fingerprint Terminals - CWE-798: Use of Hard-coded Credentials
The Dataprobe iBoot PDU running firmware version 1.43.03312023 or earlier uses hard-coded credentials for all interactions with the internal Postgres database. A malicious agent with the ability to execute operating system commands on the device can leverage this vulnerability to read, modify, or delete arbitrary database records.
Dromara Lamp-Cloud before v3.8.1 was discovered to use a hardcoded cryptographic key when creating and verifying a Json Web Token. This vulnerability allows attackers to authenticate to the application via a crafted JWT token.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
All versions of the qBittorrent client through 4.5.5 use default credentials when the web user interface is enabled. The administrator is not forced to change the default credentials. As of 4.5.5, this issue has not been fixed. A remote attacker can use the default credentials to authenticate and execute arbitrary operating system commands using the "external program" feature in the web user interface. This was reportedly exploited in the wild in March 2023.
A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508.
Dromara Sureness before v1.0.8 was discovered to use a hardcoded key.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts.
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP.