Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
â–¼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:18 Jun, 2020 | 16:21
Updated At:04 Aug, 2024 | 12:46
Rejected At:
â–¼CVE Numbering Authority (CNA)

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
3.09.6CRITICAL
CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N
Version: 3.0
Base score: 9.6
Base severity: CRITICAL
Vector:
CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042
x_refsource_CONFIRM
Hyperlink: https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042
Resource:
x_refsource_CONFIRM
â–¼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042
x_refsource_CONFIRM
x_transferred
Hyperlink: https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
â–¼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:18 Jun, 2020 | 17:15
Updated At:21 Jul, 2021 | 11:39

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Secondary3.09.6CRITICAL
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L
Primary2.03.3LOW
AV:A/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.0
Base score: 9.6
Base severity: CRITICAL
Vector:
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L
Type: Primary
Version: 2.0
Base score: 3.3
Base severity: LOW
Vector:
AV:A/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

NETGEAR, Inc.
netgear
>>rbk752>>-
cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk752_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk753>>-
cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk753_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk753s>>-
cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk753s_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr750>>-
cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr750_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs750>>-
cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs750_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk842>>-
cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk842_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr840>>-
cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr840_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs840>>-
cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs840_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk852_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk852>>-
cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk853_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbk853>>-
cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr850_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbr850>>-
cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs850_firmware>>Versions before 3.2.15.25(exclusive)
cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*
NETGEAR, Inc.
netgear
>>rbs850>>-
cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
NVD-CWE-noinfoPrimarynvd@nist.gov
CWE ID: NVD-CWE-noinfo
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042cve@mitre.org
Vendor Advisory
Hyperlink: https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042
Source: cve@mitre.org
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

230Records found

CVE-2018-21169
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.60% / 45.07%
||
7 Day CHG~0.00%
Published-27 Apr, 2020 | 17:32
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7000 before 2018-03-01, D7800 before 1.0.1.31, D8500 before 1.0.3.36, JNR1010v2 before 1.1.0.46, JR6150 before 1.0.1.14, JWNR2010v5 before 1.1.0.46, PR2000 before 2018-03-01, R6050 before 1.0.1.14, R6220 before 1.1.0.60, R6400 before 1.1.0.26, R6400v2 before 1.0.2.46, R6700v2 before 1.2.0.2, R6800 before 1.2.0.2, R6900v2 before 1.2.0.2, R7300DST before 1.0.0.56, R7500 before 1.0.0.112, R7500v2 before 1.0.3.24, R7800 before 1.0.2.36, R7900P before 1.1.4.6, R8000P before 1.1.4.6, R8300 before 1.0.2.104, R8500 before 1.0.2.104, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.94, WNDR3700v5 before 1.1.0.50, WNDR4300 before 1.0.2.96, WNDR4300v2 before 1.0.0.52, WNDR4500v3 before 1.0.0.52, WNR1000v4 before 1.1.0.46, WNR2020 before 1.1.0.46, and WNR2050 before 1.1.0.46.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-jnr1010_firmwarewnr2020_firmwarewndr3700wnr2020r6220_firmwarepr2000r6400_firmwarejwnr2010d7800r8000pwndr4300_firmwarer7500_firmwarer6800r7300dst_firmwarer8300r8500_firmwarer6050pr2000_firmwarewnr1000_firmwarer6220r8000p_firmwarewndr4500r7300dstd8500_firmwarer7900pd7800_firmwared7000r8500r9000_firmwared8500d7000_firmwarer6700r8300_firmwarewndr3700_firmwarewnr1000wndr4500_firmwarer6900r7500r9000r6900_firmwarer6050_firmwarer7800wnr2050jr6150_firmwarejr6150wnr2050_firmwarewndr4300jnr1010r7800_firmwarer6400r6700_firmwarer7900p_firmwarer6800_firmwarejwnr2010_firmwaren/a
CVE-2020-28373
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.00% / 58.88%
||
7 Day CHG~0.00%
Published-09 Nov, 2020 | 21:32
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

upnpd on certain NETGEAR devices allows remote (LAN) attackers to execute arbitrary code via a stack-based buffer overflow. This affects R6400v2 V1.0.4.102_10.0.75, R6400 V1.0.1.62_1.0.41, R7000P V1.3.2.126_10.1.66, XR300 V1.0.3.50_10.3.36, R8000 V1.0.4.62, R8300 V1.0.2.136, R8500 V1.0.2.136, R7300DST V1.0.0.74, R7850 V1.0.5.64, R7900 V1.0.4.30, RAX20 V1.0.2.64, RAX80 V1.0.3.102, and R6250 V1.0.4.44.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8500rax80r7850_firmwarer8300_firmwarer6400v2r8000xr300r6400_firmwarerax80_firmwarer7900r7000pr6250r6400v2_firmwarer8300r8500_firmwarer7300dst_firmwarexr300_firmwarer7900_firmwarer7850rax20r7300dstr6400rax20_firmwarer6250_firmwarer8000_firmwarer7000p_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-27866
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-8.66% / 94.53%
||
7 Day CHG~0.00%
Published-11 Feb, 2021 | 23:35
Updated-04 Aug, 2024 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R6020, R6080, R6120, R6220, R6260, R6700v2, R6800, R6900v2, R7450, JNR3210, WNR2020, Nighthawk AC2100, and Nighthawk AC2400 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the mini_httpd service, which listens on TCP port 80 by default. The issue results from incorrect string matching logic when accessing protected pages. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-11355.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r6850_firmwarer6120r7450_firmwarer6220_firmwareac2600ac2400r6080_firmwarer7200_firmwarer6120_firmwarer6800r6260_firmwarer6260r6220r6020r6330_firmwareac2400_firmwarer7350_firmwarer7400_firmwarer6020_firmwarer7200r6350_firmwarer6080r6230r6700r6330r6800_firmwarer6230_firmwareac2100_firmwarer6900r6900_firmwarer7400ac2100r7450r6350r6850r6700_firmwarer7350ac2600_firmwareMultiple Routers
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-287
Improper Authentication
CVE-2020-26900
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.52% / 40.80%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:33
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26906
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.61% / 45.45%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:32
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26911
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.3||HIGH
EPSS-0.53% / 41.10%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:31
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6200 before 1.1.00.38, D7000 before 1.0.1.78, JR6150 before 1.0.1.24, R6020 before 1.0.0.42, R6050 before 1.0.1.24, R6080 before 1.0.0.42, R6120 before 1.0.0.66, R6220 before 1.1.0.100, R6260 before 1.1.0.64, R6700v2 before 1.2.0.62, R6800 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, and WNR2020 before 1.1.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r6700v2_firmwared7000wnr2020_firmwarer6120r6080r7450_firmwarewnr2020d7000_firmwarer6220_firmwarer6080_firmwarer6900v2r6120_firmwared6200_firmwarer6800r6900v2_firmwarer6050_firmwarer6700v2r6050r7450r6260_firmwarer6260r6220r6020jr6150_firmwared6200jr6150r6020_firmwarer6800_firmwaren/a
CVE-2020-26899
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.77% / 51.50%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:34
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26901
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.51% / 40.31%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:33
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850rbk752_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26898
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.60% / 44.96%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:34
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR RAX40 devices before 1.0.3.80 are affected by incorrect configuration of security settings.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax40_firmwarerax40n/a
CVE-2020-26920
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.17% / 64.04%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:28
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.3.110, SRR60 before 2.5.3.110, and SRS60 before 2.5.3.110.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-srk60_firmwaresrr60srs60_firmwaresrk60srs60srr60_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-26921
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.3||HIGH
EPSS-0.77% / 51.39%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:28
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs810emx_firmwaregs110emxxs724em_firmwarexs512em_firmwaregs110emx_firmwarexs512emxs724emgs810emxn/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-26907
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.54% / 72.11%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:32
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850rbs850_firmwarerbr850rbk852_firmwarerbk852rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-26903
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.52% / 40.80%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:33
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26902
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.26% / 81.07%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:33
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850rbk752_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-26904
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.74% / 50.53%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:33
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852_firmwarerbr750_firmwarerbk852rbr850_firmwaren/a
CVE-2020-26897
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.61% / 45.45%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:34
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40rbs850rbk752_firmwarecbr40_firmwarerbk752rbs750_firmwarerbr750rbs750rbs850_firmwarerbr850rbk852rbr750_firmwarerbk852_firmwarerbr850_firmwaren/a
CVE-2020-26931
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.40% / 32.57%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:24
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wc7500_firmwarewc9500wc7500wc7600_firmwarewc9500_firmwarewc7600n/a
CVE-2020-26909
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.49% / 82.85%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:31
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.58 and R7500v2 before 1.0.3.48.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer7500v2r7500v2_firmwared7800n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-26924
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-3.1||LOW
EPSS-0.56% / 42.92%
||
7 Day CHG~0.00%
Published-09 Oct, 2020 | 06:27
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WAC720 before 3.9.1.13 and WAC730 before 3.9.1.13.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wac720wac730_firmwarewac720_firmwarewac730n/a
CVE-2020-25067
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.01% / 78.66%
||
7 Day CHG~0.00%
Published-01 Sep, 2020 | 03:22
Updated-04 Aug, 2024 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR R8300 devices before 1.0.2.134 are affected by command injection by an unauthenticated attacker.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8300_firmwarer8300n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-17409
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-6.5||MEDIUM
EPSS-0.70% / 48.98%
||
7 Day CHG~0.00%
Published-13 Oct, 2020 | 17:10
Updated-04 Aug, 2024 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of NETGEAR R6120, R6080, R6260, R6220, R6020, JNR3210, and WNR2020 routers with firmware 1.0.66. Authentication is not required to exploit this vulnerability. The specific flaw exists within the mini_httpd service, which listens on TCP port 80 by default. The issue results from incorrect string matching logic when accessing protected pages. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-10754.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r6350_firmwarewnr2020_firmwarer6120r6850_firmwarer6080wnr2020r6230r6220_firmwarer6330jnr3210_firmwarer6080_firmwarer6230_firmwarer6120_firmwarer6850r6260r6260_firmwarer6350r6220jnr3210r6020r6330_firmwarer6020_firmwareMultiple Routers
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CVE-2020-15635
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-2.64% / 83.92%
||
7 Day CHG~0.00%
Published-19 Aug, 2020 | 20:55
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6700 V1.0.4.84_10.0.58 routers with firmware 1.0.4.84_10.0.58. Authentication is not required to exploit this vulnerability. The specific flaw exists within the acsd service, which listens on TCP port 5916 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-9853.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r6700_firmwarer6700R6700
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2020-15416
Matching Score-8
Assigner-Zero Day Initiative
ShareView Details
Matching Score-8
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-6.42% / 92.93%
||
7 Day CHG~0.00%
Published-28 Jul, 2020 | 17:10
Updated-04 Aug, 2024 | 13:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R6700 V1.0.4.84_10.0.58 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the httpd service, which listens on TCP port 80 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length, stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-9703.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-r6700_firmwarer6700R6700
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2020-14437
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.84% / 76.63%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:37
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14439
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.42% / 82.37%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:38
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14436
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.29% / 81.35%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:35
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14438
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.84% / 76.63%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:38
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14442
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.84% / 76.63%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:40
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14426
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.54% / 41.84%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:20
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852rbk852_firmwarerbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CVE-2020-14435
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-1.00% / 59.05%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:35
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-srk60b04_firmwaresrk60b06_firmwaresrk60b05_firmwaresrk60b06srk60b03_firmwaresrk60_firmwaresrk60b05srr60srs60_firmwaresrk60srs60srk60b04srk60b03srr60_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14431
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.81% / 52.86%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:26
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CVE-2020-14428
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.77% / 51.45%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:21
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CVE-2020-14440
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-3.09% / 86.28%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:39
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14441
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.84% / 76.63%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 16:39
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs750_firmwarerbs850_firmwarerbr850rbr750_firmwarerbk842rbk853_firmwarerbs850rbk752_firmwarerbk753_firmwarerbk752rbr750rbs750rbs840_firmwarerbk853rbr840rbk753rbk753srbr840_firmwarerbk852_firmwarerbk852rbk842_firmwarerbk753s_firmwarerbr850_firmwarerbs840n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-21204
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.57% / 43.30%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:11
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwarewndr3700wndr3700_firmwarewndr4500_firmwared7800r6100_firmwarer9000r7500wndr4300_firmwarer7500_firmwarer7800wndr4500r6100wndr4300r7800_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-21211
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.73% / 50.18%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:34
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwared6000_firmwarewndr3700wndr3700_firmwarewndr4500_firmwared7800wnr2000_firmwared6000r9000r7500wndr4300_firmwared3600_firmwarer7500_firmwarer7800d6100_firmwared6100wndr4500d3600wndr4300r7800_firmwarewnr2000n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21210
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.63% / 46.17%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:33
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wn2000rpt_firmwarewn3000rp_firmwared7800_firmwarewn3000rpr900d6000_firmwarewndr3700wndr3700_firmwarer900_firmwared7800r6100_firmwarewndr4500_firmwareex2700d6000wn3100rp_firmwarewn2000rptwndr4300_firmwarer7500d3600_firmwarer7500_firmwarer7800wn3100rpex2700_firmwarewndr4500d3600r6100wndr4300r7800_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21212
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.72% / 49.94%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:36
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, WN3100RPv2 before 1.0.0.56, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wn2000rpt_firmwarewn3000rp_firmwared7800_firmwarewn3000rpr900d6000_firmwarewndr3700wndr3700_firmwarer900_firmwared7800r6100_firmwarewndr4500_firmwareex2700d6000wn3100rp_firmwarewn2000rptwndr4300_firmwarer7500d3600_firmwarer7500_firmwarer7800wn3100rpex2700_firmwared6100_firmwared6100wndr4500d3600r6100wndr4300r7800_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21223
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.63% / 46.17%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 16:26
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwared6000_firmwarewndr3700wndr3700_firmwarewndr4500_firmwared7800r6100_firmwarewnr2000_firmwared6000r9000r7500wndr4300_firmwared3600_firmwarer7500_firmwarewndr4500d3600r6100wndr4300wnr2000n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21214
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.69% / 48.90%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:40
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, EX2700 before 1.0.1.28, R6100 before 1.0.1.20, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.50, and WN3100RPv2 before 1.0.0.56.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wn2000rpt_firmwarewn3000rp_firmwarewn3000rpr9000_firmwared6000_firmwarer6100_firmwared6000ex2700wn2000rptwn3100rp_firmwarer9000r7500r7500_firmwared3600_firmwarewn3100rpex2700_firmwared3600r6100n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21123
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.49% / 71.20%
||
7 Day CHG+0.06%
Published-22 Apr, 2020 | 15:48
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wc7500_firmwarewc7520wc7500wc7520_firmwarewc7600_firmwarewc7600n/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2018-21093
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.4||MEDIUM
EPSS-0.61% / 45.18%
||
7 Day CHG~0.00%
Published-27 Apr, 2020 | 14:41
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D8500 before 1.0.3.42, EX3700 before 1.0.0.70, EX3800 before 1.0.0.70, EX6000 before 1.0.0.30, EX6100 before 1.0.2.24, EX6120 before 1.0.0.40, EX6130 before 1.0.0.22, EX6150 before 1.0.0.42, EX6200 before 1.0.3.88, EX7000 before 1.0.0.66, R6250 before 1.0.4.26, R6300-2CXNAS before 1.0.3.60, R6300v2 before 1.0.4.28, R6400 before 1.0.1.36, R6400v2 before 1.0.2.52, R6700 before 1.0.1.46, R6900 before 1.0.1.46, R7000 before 1.0.9.28, R7000P before 1.3.1.44, R6900P before 1.3.1.44, R7100LG before 1.0.0.46, R7300 before 1.0.0.68, R7900 before 1.0.2.10, R8000 before 1.0.4.18, R8000P before 1.3.0.10, R7900P before 1.3.0.10, R8500 before 1.0.2.122, R8300 before 1.0.2.122, RBW30 before 2.1.2.6, WN2500RPv2 before 1.0.0.54, and WNR3500Lv2 before 1.2.0.56.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7300rbw30_firmwarer7300_firmwarer8000r6400_firmwareex3800_firmwareex6200ex7000r6900pr7100lgr7900r8000pex3700r6900p_firmwarerbw30r8500_firmwarer7100lg_firmwarer8300r7000_firmwarer6300-2cxnas_firmwarer6300-2cxnasr8000p_firmwarewn2500rpwn2500rp_firmwarer6300_firmwareex6130d8500_firmwarer6250_firmwarer7900pex6000_firmwareex6100r7000p_firmwarer8500ex6130_firmwared8500r6700r8300_firmwarer7000wnr3500l_firmwareex6200_firmwareex6150r6900r7000pwnr3500lr6900_firmwareex3800r7900_firmwareex6100_firmwareex3700_firmwareex6000ex7000_firmwareex6120r6300r6400r6700_firmwarer7900p_firmwareex6120_firmwareex6150_firmwarer8000_firmwarer6250n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-21113
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.64% / 73.70%
||
7 Day CHG+0.07%
Published-22 Apr, 2020 | 14:38
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D6100 before 1.0.0.58, D7800 before 1.0.1.42, R6100 before 1.0.1.28, R7500 before 1.0.0.130, R7500v2 before 1.0.3.36, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WNDR3700v4 before 1.0.2.102, WNDR4300 before 1.0.2.104, WNDR4300v2 before 1.0.0.56, and WNDR4500v3 before 1.0.0.56.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer8900r9000_firmwarewndr3700r8900_firmwarewndr3700_firmwarewndr4500_firmwared7800r6100_firmwarer9000r7500wndr4300_firmwarer7500_firmwarer7800d6100_firmwared6100wndr4500r6100wndr4300r7800_firmwaren/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2018-21218
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.72% / 49.94%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:43
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwared6000_firmwarewndr3700wndr3700_firmwarewnr2000_firmwared7800r6100_firmwarewndr4500_firmwared6000r9000r7500wndr4300_firmwarer7500_firmwared3600_firmwared6100_firmwared6100wndr4500d3600r6100wndr4300wnr2000n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21213
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.63% / 46.17%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:40
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, and WNDR4500v3 before 1.0.0.50.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwared6000_firmwarewndr3700wndr3700_firmwarewndr4500_firmwared7800r6100_firmwared6000r9000r7500wndr4300_firmwarer7500_firmwared3600_firmwarer7800wndr4500d3600r6100wndr4300r7800_firmwaren/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21130
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.62% / 73.39%
||
7 Day CHG+0.07%
Published-22 Apr, 2020 | 17:35
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wac505_firmwarewac510_firmwarewac505wac510n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-21216
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.69% / 48.90%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:42
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, and R6100 before 1.0.1.20.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d3600_firmwared6000_firmwared6100_firmwared6100d3600r6100r6100_firmwared6000n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2018-21158
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.61% / 45.16%
||
7 Day CHG~0.00%
Published-27 Apr, 2020 | 17:25
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR R7800 devices before 1.0.2.46 are affected by incorrect configuration of security settings.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7800r7800_firmwaren/a
CVE-2018-21126
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-1.49% / 71.20%
||
7 Day CHG+0.06%
Published-22 Apr, 2020 | 15:51
Updated-05 Aug, 2024 | 12:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WAC505 before 5.0.0.17 and WAC510 before 5.0.0.17.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wac505_firmwarewac510_firmwarewac505wac510n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-21219
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.63% / 46.27%
||
7 Day CHG~0.00%
Published-28 Apr, 2020 | 15:44
Updated-05 Aug, 2024 | 12:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-d7800_firmwarer9000_firmwared6000_firmwarewndr3700wndr3700_firmwarewnr2000_firmwared7800r6100_firmwarewndr4500_firmwared6000r9000r7500wndr4300_firmwarer7500_firmwared3600_firmwared6100_firmwared6100wndr4500d3600r6100wndr4300wnr2000n/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')