A vulnerability in the HTTPS proxy feature of Cisco Wide Area Application Services (WAAS) Software could allow an unauthenticated, remote attacker to use the Central Manager as an HTTPS proxy. The vulnerability is due to insufficient authentication of proxy connection requests. An attacker could exploit this vulnerability by sending a malicious HTTPS CONNECT message to the Central Manager. A successful exploit could allow the attacker to access public internet resources that would normally be blocked by corporate policies.
includes/class-coming-soon-creator.php in the igniteup plugin through 3.4 for WordPress allows unauthenticated arbitrary file deletion.
Functions/EWD_UFAQ_Import.php in the ultimate-faqs plugin through 1.8.24 for WordPress allows unauthenticated options import.
search-exclude.php in the "Search Exclude" plugin before 1.2.4 for WordPress allows unauthenticated options changes.
A vulnerability in the configuration import utility of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to have write access and upload arbitrary data to the filesystem. The vulnerability is due to a failure to delete temporarily uploaded files. An attacker could exploit this vulnerability by crafting a malicious file and uploading it to the affected device. An exploit could allow the attacker to fill up the filesystem or upload malicious scripts.
The udpServerSys service in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to initiate firmware upgrades and alter device settings.
A security vulnerability exists in the Zingbox Inspector versions 1.280 and earlier, where authentication is not required when binding the Inspector instance to a different customer tenant.
VDSM and libvirt in Red Hat Enterprise Virtualization Hypervisor (aka RHEV-H) 7-7.x before 7-7.2-20151119.0 and 6-6.x before 6-6.7-20151117.0 as packaged in Red Hat Enterprise Virtualization before 3.5.6 when VSDM is run with -spice disable-ticketing and a VM is suspended and then restored, allows remote attackers to log in without authentication via unspecified vectors.
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
An issue was discovered in Joomla! before 3.9.5. The "refresh list of helpsites" endpoint of com_users lacks access checks, allowing calls from unauthenticated users.
Missing Authentication for Critical Function vulnerability in Microchip TimePictra allows Configuration/Environment Manipulation.This issue affects TimePictra: from 11.0 through 11.3 SP2.
Yoke is a Helm-inspired infrastructure-as-code (IaC) package deployer. In 0.19.0 and earlier, a vulnerability exists in the Air Traffic Controller (ATC) component of Yoke. The ATC webhook endpoints lack proper authentication mechanisms, allowing any pod within the cluster network to directly send AdmissionReview requests to the webhook, bypassing Kubernetes API Server authentication. This enables attackers to trigger WASM module execution in the ATC controller context without proper authorization.
PolarLearn is a free and open-source learning program. In 0-PRERELEASE-16 and earlier, the group chat WebSocket at wss://polarlearn.nl/api/v1/ws can be used without logging in. An unauthenticated client can subscribe to any group chat by providing a group UUID, and can also send messages to any group. The server accepts the message and stores it in the group’s chatContent, so this is not just a visual spam issue.
OpenClaw is a personal AI assistant. Versions 2026.2.13 and below allow the optional @openclaw/voice-call plugin Telnyx webhook handler to accept unsigned inbound webhook requests when telnyx.publicKey is not configured, enabling unauthenticated callers to forge Telnyx events. Telnyx webhooks are expected to be authenticated via Ed25519 signature verification. In affected versions, TelnyxProvider.verifyWebhook() could effectively fail open when no Telnyx public key was configured, allowing arbitrary HTTP POST requests to the voice-call webhook endpoint to be treated as legitimate Telnyx events. This only impacts deployments where the Voice Call plugin is installed, enabled, and the webhook endpoint is reachable from the attacker (for example, publicly exposed via a tunnel/proxy). The issue has been fixed in version 2026.2.14.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
SAP Process Integration, business-to-business add-on, versions 1.0, 2.0, does not perform authentication check properly when the default security provider is changed to BouncyCastle (BC), leading to Missing Authentication Check
An issue was discovered in SysAid ITIL 20.4.74 b10. The /enduserreg endpoint is used to register end users anonymously, but does not respect the server-side setting that determines if anonymous users are allowed to register new accounts. Configuring the server-side setting to disable anonymous user registration only hides the client-side registration form. An attacker can still post registration data to create new accounts without prior authentication.
In WhatsUp Gold versions released before 2024.0.2, an unauthenticated attacker can configure LDAP settings.
Missing authentication in the SetStudentNotes method in IDAttend’s IDWeb application 3.1.052 and earlier allows modification of student data by unauthenticated attackers.
Apollo is a configuration management system. Prior to version 2.1.0, there are potential security issues if users expose apollo-configservice to the internet, which is not recommended. This is because there is no authentication feature enabled for the built-in eureka service. Malicious hackers may access eureka directly to mock apollo-configservice and apollo-adminservice. Login authentication for eureka was added in version 2.1.0. As a workaround, avoid exposing apollo-configservice to the internet.
An issue was discovered in the femanager extension before 5.5.3, 6.x before 6.3.4, and 7.x before 7.1.0 for TYPO3. Missing access checks in the InvitationController allow an unauthenticated user to delete all frontend users.
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
An issue was discovered in the femanager extension before 5.5.3, 6.x before 6.3.4, and 7.x before 7.1.0 for TYPO3. Missing access checks in the InvitationController allow an unauthenticated user to set the password of all frontend users.
Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
Vulnerability in the Oracle iSetup product of Oracle E-Business Suite (component: General Ledger Update Transform, Reports). Supported versions that are affected are 12.2.3-12.2.12. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle iSetup. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle iSetup accessible data. CVSS 3.1 Base Score 7.5 (Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
A remote unauthenticated attacker may be able to bypass authentication by utilizing a specific API route to execute arbitrary OS commands.
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
Gnuboard 5.5.4 and 5.5.5 is vulnerable to Insecure Permissions. An attacker can change password of all users without knowing victim's original password.
getgps data in iTrack Easy can be modified without authentication by setting the data using the parametercmd:setothergps. This vulnerability can be exploited to alter the GPS data of a lost device.
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
A vulnerability, which was classified as problematic, was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is an unknown function of the file /wizard.html of the component Password Reset Handler. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272568. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
The includes/gateways/stripe/includes/admin/admin-actions.php in GiveWP plugin through 2.5.9 for WordPress allows unauthenticated settings change.
An access control issue in Canaan Avalon ASIC Miner 2020.3.30 and below allows unauthenticated attackers to arbitrarily change user passwords via a crafted POST request.
Insecure permissions in cskefu v7.0.1 allows unauthenticated attackers to arbitrarily add administrator accounts.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable an authentication profile server via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable an authentication profile server via crafted HTTP requests.
Lack of authentication in the network relays used in MEGVII Koala 2.9.1-c3s allows attackers to grant physical access to anyone by sending packet data to UDP port 5000.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable front panel authentication via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to set an arbitrary authentication profile server via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable front panel authentication via crafted HTTP requests.
The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
An issue was discovered in Couchbase Server before 7.0.4. The Index Service does not enforce authentication for TCP/TLS servers.
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known.
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.