Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2020-6765

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-10 Apr, 2020 | 18:26
Updated At-04 Aug, 2024 | 09:11
Rejected At-
Credits

D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:10 Apr, 2020 | 18:26
Updated At:04 Aug, 2024 | 09:11
Rejected At:
▼CVE Numbering Authority (CNA)

D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165
x_refsource_CONFIRM
Hyperlink: https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165
x_refsource_CONFIRM
x_transferred
Hyperlink: https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:10 Apr, 2020 | 19:15
Updated At:13 Apr, 2020 | 13:57

D-Link DSL-GS225 J1 AU_1.0.4 devices allow an admin to execute OS commands by placing shell metacharacters after a supported CLI command, as demonstrated by ping -c1 127.0.0.1; cat/etc/passwd. The CLI is reachable by TELNET.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

D-Link Corporation
dlink
>>dsl-gs225>>j1
cpe:2.3:h:dlink:dsl-gs225:j1:*:*:*:*:*:*:*
D-Link Corporation
dlink
>>dsl-gs225_firmware>>Versions up to au_1.0.4(inclusive)
cpe:2.3:o:dlink:dsl-gs225_firmware:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165cve@mitre.org
Patch
Vendor Advisory
Hyperlink: https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10165
Source: cve@mitre.org
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1178Records found

CVE-2019-10999
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-35.80% / 96.96%
||
7 Day CHG~0.00%
Published-06 May, 2019 | 19:30
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below).

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dcs-932ldcs-931ldcs-5030l_firmwaredcs-930ldcs-932l_firmwaredcs-5020l_firmwaredcs-5025l_firmwaredcs-933l_firmwaredcs-5020ldcs-5010l_firmwaredcs-930l_firmwaredcs-934ldcs-5025ldcs-934l_firmwaredcs-933ldcs-5030ldcs-5009ldcs-931l_firmwaredcs-5009l_firmwaredcs-5010ln/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-5151
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.52% / 65.97%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:31
Updated-24 Sep, 2024 | 19:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 autheditpwd.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-8000 up to 20151231. Affected by this vulnerability is an unknown functionality of the file /autheditpwd.php. The manipulation of the argument hid_id leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240247. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-8000DAR-8000dar-8000_firmware
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-8956
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 26.27%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7922
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 80.82%
||
7 Day CHG~0.00%
Published-19 Aug, 2024 | 15:00
Updated-20 Aug, 2024 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 myMusic.cgi cgi_write_playlist command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814 and classified as critical. Affected by this issue is the function cgi_audio_search/cgi_create_playlist/cgi_get_album_all_tracks/cgi_get_alltracks_editlist/cgi_get_artist_all_album/cgi_get_genre_all_tracks/cgi_get_tracks_list/cgi_set_airplay_content/cgi_write_playlist of the file /cgi-bin/myMusic.cgi. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link CorporationDell Inc.
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-120_firmwaredns-326_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-343_firmwarednr-202l_firmwaredns-320lw_firmwaredns-323_firmwaredns-320_firmwaredns-315l_firmwaredns-321_firmwaredns-320l_firmwarednr-322l_firmwaredns-325_firmwaredns-120_firmwaredns-326_firmwaredns-1550-04_firmwaredns-726-4_firmwaredns-1200-05_firmwaredns-340l_firmwaredns-1100-4_firmwarednr-326_firmwaredns-345_firmwaredns-327l_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-5150
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.28% / 50.72%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:31
Updated-18 Jun, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 web.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000 and DAR-8000 up to 20151231. Affected is an unknown function of the file /useratte/web.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-240246 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-8000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-7715
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.35% / 57.02%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 06:31
Updated-15 Aug, 2024 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 photocenter_mgr.cgi sprintf command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240812. It has been classified as critical. This affects the function sprintf of the file /cgi-bin/photocenter_mgr.cgi. The manipulation of the argument filter leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-DNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-120_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7192
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 30.84%
||
7 Day CHG~0.00%
Published-08 Jul, 2025 | 19:32
Updated-14 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-645 ssdpcgi cgibin ssdpcgi_main command injection

A vulnerability was found in D-Link DIR-645 up to 1.05B01 and classified as critical. This issue affects the function ssdpcgi_main of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-645_firmwaredir-645DIR-645
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-5146
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.88% / 74.47%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 00:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 updatelib.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231 and classified as critical. Affected by this issue is some unknown functionality of the file /sysmanage/updatelib.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-240242 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5148
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.08% / 83.26%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:00
Updated-24 Sep, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 uploadfile.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231. It has been declared as critical. This vulnerability affects unknown code of the file /Tool/uploadfile.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240244. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000dar-8000_firmwaredar-7000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5149
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.41% / 60.59%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 userattestation.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2025-5492
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 15.80%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-20674
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.59% / 68.10%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 00:00
Updated-16 Sep, 2024 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-822 C1 before v3.11B01Beta, DIR-822-US C1 before v3.11B01Beta, DIR-850L A* before v1.21B08Beta, DIR-850L B* before v2.22B03Beta, and DIR-880L A* before v1.20B02Beta devices allow authenticated remote command execution.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-822-usdir-850ldir-880ldir-850l_firmwaredir-822_firmwaredir-880l_firmwaredir-822dir-822-us_firmwaren/a
CVE-2021-20694
Matching Score-8
Assigner-JPCERT/CC
ShareView Details
Matching Score-8
Assigner-JPCERT/CC
CVSS Score-8.8||HIGH
EPSS-0.20% / 42.63%
||
7 Day CHG~0.00%
Published-26 Apr, 2021 | 00:20
Updated-03 Aug, 2024 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper access control vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to bypass access restriction and to start a telnet service via unspecified vectors.

Action-Not Available
Vendor-D-Link Corporation
Product-dap-1880acdap-1880ac_firmwareDAP-1880AC
CVE-2018-17442
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.01% / 91.09%
||
7 Day CHG~0.00%
Published-08 Oct, 2018 | 16:00
Updated-05 Aug, 2024 | 10:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link Central WiFi Manager before v 1.03r0100-Beta1. An unrestricted file upload vulnerability in the onUploadLogPic endpoint allows remote authenticated users to execute arbitrary PHP code.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-central_wifimanagern/a
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2022-46568
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the AccountPassword parameter in the SetSysEmailSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46562
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.76% / 72.36%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the PSK parameter in the SetQuickVPNSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46566
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Password parameter in the SetQuickVPNSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46561
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Password parameter in the SetWanSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46569
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.76% / 72.36%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Key parameter in the SetWLanRadioSecurity module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46570
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Password parameter in the SetWan3Settings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46560
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Password parameter in the SetWan2Settings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4883
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.25% / 48.33%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 14:31
Updated-21 May, 2025 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8100 Connection Limit Page ctxz.asp ctxz_asp stack-based overflow

A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been declared as critical. This vulnerability affects the function ctxz_asp of the file /ctxz.asp of the component Connection Limit Page. The manipulation of the argument def/defTcp/defUdp/defIcmp/defOther leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8100g_firmwaredi-8100gDI-8100
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46563
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.05% / 76.61%
||
7 Day CHG~0.00%
Published-23 Dec, 2022 | 00:00
Updated-15 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the Password parameter in the SetDynamicDNSSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_a1dir-882_a1_firmwaren/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4454
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4445
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 29.79%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 22.65%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4341
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 16.55%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:31
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-880L Request Header ssdpcgi sub_16570 command injection

A vulnerability classified as critical was found in D-Link DIR-880L up to 104WWb01. Affected by this vulnerability is the function sub_16570 of the file /htdocs/ssdpcgi of the component Request Header Handler. The manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-880l_firmwaredir-880lDIR-880L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4544
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-7.5||HIGH
EPSS-0.24% / 46.90%
||
7 Day CHG~0.00%
Published-11 May, 2025 | 18:31
Updated-22 May, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8100 jhttpd ddos.asp stack-based overflow

A vulnerability was found in D-Link DI-8100 up to 16.07.26A1 and classified as critical. This issue affects some unknown processing of the file /ddos.asp of the component jhttpd. The manipulation of the argument def_max/def_time/def_tcp_max/def_tcp_time/def_udp_max/def_udp_time/def_icmp_max leads to stack-based buffer overflow. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8100di-8100_firmwareDI-8100
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-10713
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.53% / 66.44%
||
7 Day CHG~0.00%
Published-03 May, 2018 | 16:00
Updated-16 Sep, 2024 | 18:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'read' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'read <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-3782_firmwaredsl-3782n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-29778
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-25.24% / 95.98%
||
7 Day CHG~0.00%
Published-03 Jun, 2022 | 20:19
Updated-28 Oct, 2024 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-890L 1.20b01 allows attackers to execute arbitrary code due to the hardcoded option Wake-On-Lan for the parameter 'descriptor' at SetVirtualServerSettings.php

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-890l_firmwaredir-890ln/adir-890l_firmware
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2025-29039
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.24%
||
7 Day CHG~0.00%
Published-17 Apr, 2025 | 00:00
Updated-25 Apr, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in dlink DIR 832x 240802 allows a remote attacker to execute arbitrary code via the function 0x41dda8

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823x_firmwaredir-823xn/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2019-9122
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-9.63% / 92.58%
||
7 Day CHG~0.00%
Published-25 Feb, 2019 | 05:00
Updated-04 Aug, 2024 | 21:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. They allow remote attackers to execute arbitrary commands via the ntp_server parameter in an ntp_sync.cgi POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-825_rev.b_firmwaredir-825_rev.bn/a
CVE-2025-25743
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.85% / 82.24%
||
7 Day CHG~0.00%
Published-12 Feb, 2025 | 00:00
Updated-05 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-853 A1 FW1.20B07 was discovered to contain a command injection vulnerability in the SetVirtualServerSettings module.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-853_firmwaredir-853n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-5143
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.45% / 62.55%
||
7 Day CHG~0.00%
Published-24 Sep, 2023 | 22:31
Updated-06 Mar, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 webmailattach.php Privilege Escalation

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000 up to 20151231. This issue affects some unknown processing of the file /log/webmailattach.php. The manipulation of the argument table_name leads to an unknown weakness. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240239. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000dar-7000_firmwareDAR-7000
CWE ID-CWE-20
Improper Input Validation
CVE-2023-5153
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.43% / 61.38%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 02:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 querysql.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-8000 up to 20151231. This affects an unknown part of the file /Tool/querysql.php. The manipulation leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240249 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-8000
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-1800
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.20%
||
7 Day CHG~0.00%
Published-01 Mar, 2025 | 18:00
Updated-21 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 HTTP POST Request sxh_vpnlic.php get_ip_addr_details command injection

A vulnerability has been found in D-Link DAR-7000 3.2 and classified as critical. This vulnerability affects the function get_ip_addr_details of the file /view/vpn/sxh_vpn/sxh_vpnlic.php of the component HTTP POST Request Handler. The manipulation of the argument ethname leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7436
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 80.81%
||
7 Day CHG~0.00%
Published-03 Aug, 2024 | 14:00
Updated-11 Sep, 2024 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8100 msp_info.htm msp_info_htm command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07. This issue affects the function msp_info_htm of the file msp_info.htm. The manipulation of the argument cmd leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273521 was assigned to this vulnerability.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8100di-8100_firmwareDI-8100di-8100
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8212
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.60% / 68.44%
||
7 Day CHG~0.00%
Published-27 Aug, 2024 | 19:31
Updated-29 Aug, 2024 | 15:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 hd_config.cgi cgi_FMT_R12R5_2nd_DiskMGR command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814. It has been rated as critical. This issue affects the function cgi_FMT_R12R5_2nd_DiskMGR of the file /cgi-bin/hd_config.cgi. The manipulation of the argument f_source_dev leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-326_firmwaredns-120_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-726-4_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-4963
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.39% / 79.57%
||
7 Day CHG~0.00%
Published-16 May, 2024 | 07:00
Updated-15 Jul, 2025 | 16:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000-40 url.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000-40 V31R02B1413C. This affects an unknown part of the file /url/url.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-264531. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000-40
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2021-46314
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-23.47% / 95.75%
||
7 Day CHG~0.00%
Published-17 Feb, 2022 | 20:59
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Command Execution (RCE) vulnerability exists in HNAP1/control/SetNetworkTomographySettings.php of D-Link Router DIR-846 DIR846A1_FW100A43.bin and DIR846enFW100A53DLA-Retail.bin because backticks can be used for command injection when judging whether it is a reasonable domain name.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846_firmwaredir-846n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-5295
Matching Score-6
Assigner-Zero Day Initiative
ShareView Details
Matching Score-6
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-4.49% / 88.67%
||
7 Day CHG~0.00%
Published-23 May, 2024 | 21:29
Updated-10 Mar, 2025 | 16:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link G416 flupl self Command Injection Remote Code Execution Vulnerability

D-Link G416 flupl self Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link G416 wireless routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HTTP service listening on TCP port 80. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21294.

Action-Not Available
Vendor-D-Link Corporation
Product-g416g416_firmwareG416g416_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-46441
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-22.97% / 95.69%
||
7 Day CHG~0.00%
Published-27 Apr, 2022 | 10:12
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In the "webupg" binary of D-Link DIR-825 G1, because of the lack of parameter verification, attackers can use "cmd" parameters to execute arbitrary system commands after obtaining authorization.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-825_firmwaredir-825n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-48633
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-0.43% / 61.80%
||
7 Day CHG~0.00%
Published-17 Oct, 2024 | 00:00
Updated-07 May, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR_882_FW130B06 and DIR_878 DIR_878_FW130B08 were discovered to contain multiple command injection vulnerabilities via the ExternalPort, InternalPort, ProtocolNumber, and LocalIPAddress parameters in the SetVirtualServerSettings function. This vulnerability allows attackers to execute arbitrary OS commands via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878_firmwaredir-882dir-882_firmwaredir-878n/adir-882_firmwaredir-878_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-48632
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-0.43% / 61.80%
||
7 Day CHG~0.00%
Published-17 Oct, 2024 | 00:00
Updated-07 May, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR_882_FW130B06 and DIR_878 DIR_878_FW130B08 were discovered to contain multiple command injection vulnerabilities via the LocalIPAddress, TCPPorts, and UDPPorts parameters in the SetPortForwardingSettings function. This vulnerability allows attackers to execute arbitrary OS commands via a crafted POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878_firmwaredir-882dir-882_firmwaredir-878n/adir-882_firmwaredir-878_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-6013
Matching Score-6
Assigner-JPCERT/CC
ShareView Details
Matching Score-6
Assigner-JPCERT/CC
CVSS Score-6.6||MEDIUM
EPSS-0.16% / 37.63%
||
7 Day CHG~0.00%
Published-26 Dec, 2019 | 15:16
Updated-04 Aug, 2024 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

DBA-1510P firmware 1.70b009 and earlier allows authenticated attackers to execute arbitrary OS commands via Command Line Interface (CLI).

Action-Not Available
Vendor-D-Link Corporation
Product-dba-1510p_firmwaredba-1510pDBA-1510P
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-42784
Matching Score-6
Assigner-Government Technology Agency of Singapore Cyber Security Group (GovTech CSG)
ShareView Details
Matching Score-6
Assigner-Government Technology Agency of Singapore Cyber Security Group (GovTech CSG)
CVSS Score-9.8||CRITICAL
EPSS-3.92% / 87.84%
||
7 Day CHG~0.00%
Published-23 Nov, 2021 | 21:37
Updated-04 Aug, 2024 | 03:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OS Command Injection in debug_fcgi in D-Link DWR-932C E1 Firmware 1.0.0.4

OS Command Injection vulnerability in debug_fcgi of D-Link DWR-932C E1 firmware allows a remote attacker to perform command injection via a crafted HTTP request.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-932c_e1_firmwaredwr-932cDWR-932C E1
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44333
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.12% / 32.29%
||
7 Day CHG~0.00%
Published-09 Sep, 2024 | 00:00
Updated-09 Sep, 2024 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DI-7003GV2 v24.04.18D1, DI-7100G+V2 v24.04.18D1, DI-7100GV2 v24.04.18D1, DI-7200GV2 v24.04.18E1, DI-7300G+V2 v24.04.18D1, and DI-7400G+V2 v24.04.18D1 are vulnerable to Remote Command Execution. An attacker can achieve arbitrary command execution by sending a carefully crafted malicious string to the CGI function responsible for handling usb_paswd.asp.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-n/adi-7400g\+v2_firmwaredi-7003gv2_firmwaredi-7200gv2_firmwaredi-7100gv2_firmwaredi-7100g\+v2_firmwaredi-7300g\+v2_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-46315
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-26.25% / 96.10%
||
7 Day CHG~0.00%
Published-17 Feb, 2022 | 21:15
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Remote Command Execution (RCE) vulnerability exists in HNAP1/control/SetWizardConfig.php in D-Link Router DIR-846 DIR846A1_FW100A43.bin and DIR846enFW100A53DLA-Retail.bin. Malicoius users can use this vulnerability to use "\ " or backticks in the shell metacharacters in the ssid0 or ssid1 parameters to cause arbitrary command execution. Since CVE-2019-17510 vulnerability has not been patched and improved www/hnap1/control/setwizardconfig.php, can also use line breaks and backquotes to bypass.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846_firmwaredir-846n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 23
  • 24
  • Next
Details not found