An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456.
D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded adminpldt / z6dUABtl270qRxt7a2uGTiw credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded trueadmin / admintrue credentials for an ISP.
An issue was discovered on FiberHome AN5506-04-FA devices with firmware RP2631. There is a gepon password for the gepon account.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / tele1234 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 888888 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 1234 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded L1vt1m4eng / 888888 credentials for an ISP.
D-Link DIR-456U Hardware Revision A1 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /etc/init0.d/S80telnetd.sh with the username "Alphanetworks" and the static password "whdrv01_dlob_dir456U" read from /etc/config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.
An issue was discovered on FiberHome HG6245D devices through RP2613. Credentials in /fhconf/umconfig.txt are obfuscated via XOR with the hardcoded *j7a(L#yZ98sSd5HfSgGjMj8;Ss;d)(*&^#@$a2s0i3g key. (The webs binary has details on how XOR is used.)
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a 6GFJdY4aAuUKJjdtSn7d password for the rdsadmin account.
Mutiny 7.2.0-10788 suffers from Hardcoded root password.
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / user1234 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a password of four hexadecimal characters for the admin account. These characters are generated in init_3bb_password in libci_adaptation_layer.so.
Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user.
Hard-coded FTP credentials (r:r) are included in the Foscam C1 running firmware 1.9.1.12. Knowledge of these credentials would allow remote access to any cameras found on the internet that do not have port 50021 blocked by an intermediate device.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / admin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded f~i!b@e#r$h%o^m*esuperadmin / s(f)u_h+g|u credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded awnfibre / fibre@dm!n credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / tattoo@home credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. A hardcoded GEPON password for root is defined inside /etc/init.d/system-config.sh.
An issue was discovered on FiberHome HG6245D devices through RP2613. The password for the enable command is gpon.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded gestiontelebucaramanga / t3l3buc4r4m4ng42013 credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The telnet daemon on port 23/tcp can be abused with the gpon/gpon credentials.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / lnadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / CUadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded rootmet / m3tr0r00t credentials for an ISP.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
Le-yan Personnel and Salary Management System has hard-coded database account and password within the website source code. An unauthenticated remote attacker can access, modify system data or disrupt service.
Brocade Fabric OS before Brocade Fabric OS v8.2.1c, v8.1.2h, and all versions of Brocade Fabric OS v8.0.x and v7.x contain documented hard-coded credentials, which could allow attackers to gain access to the system.
Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 3UJUh2VemEfUtesEchEC2d2e credentials for an ISP.
The trove service user in (1) Openstack deployment (aka crowbar-openstack) and (2) Trove Barclamp (aka barclamp-trove and crowbar-barclamp-trove) in the Crowbar Framework has a default password, which makes it easier for remote attackers to obtain access via unspecified vectors.
NUUO NVRmini 2 1.0.0 through 3.0.0 and NUUO NVRsolo 1.0.0 through 3.0.0 have hardcoded root credentials, which allows remote attackers to obtain administrative access via unspecified vectors.
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
Dentsply Sirona (formerly Schick) CDR Dicom 5 and earlier has default passwords for the sa and cdr accounts, which allows remote attackers to obtain administrative access by leveraging knowledge of these passwords.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
Novel-Plus v3.6.2 was discovered to contain a hard-coded JWT key located in the project config file. This vulnerability allows attackers to create a custom user session.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
Gladinet CentreStack and Triofox prior to version 16.12.10420.56791 used hardcoded values for their implementation of the AES cryptoscheme. This degrades security for public exposed endpoints that may make use of it and may offer arbitrary local file inclusion when provided a specially crafted request without authentication. This opens the door for future exploitation and can be leveraged with previous vulnerabilities to gain a full system compromise.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not).
Trendnet AC2600 TEW-827DRU version 2.08B01 makes use of hardcoded credentials. It is possible to backup and restore device configurations via the management web interface. These devices are encrypted using a hardcoded password of "12345678".