CVE-2021-20695

Summary
Assigner-jpcert
Assigner Org ID-ede6fdc4-6654-4307-a26d-3331c018e2ce
Published At-26 Apr, 2021 | 00:20
Updated At-03 Aug, 2024 | 17:45
Rejected At-
Credits

Improper following of a certificate's chain of trust vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to gain root privileges via unspecified vectors.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:jpcert
Assigner Org ID:ede6fdc4-6654-4307-a26d-3331c018e2ce
Published At:26 Apr, 2021 | 00:20
Updated At:03 Aug, 2024 | 17:45
Rejected At:
▼CVE Numbering Authority (CNA)

Improper following of a certificate's chain of trust vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to gain root privileges via unspecified vectors.

Affected Products
Vendor
D-Link CorporationD-Link Japan K.K.
Product
DAP-1880AC
Versions
Affected
  • firmware version 1.21 and earlier
Problem Types
TypeCWE IDDescription
textN/AImproper following of a certificate's chain of trust
Type: text
CWE ID: N/A
Description: Improper following of a certificate's chain of trust
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.html
x_refsource_MISC
https://jvn.jp/en/vu/JVNVU92898656/index.html
x_refsource_MISC
Hyperlink: https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.html
Resource:
x_refsource_MISC
Hyperlink: https://jvn.jp/en/vu/JVNVU92898656/index.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.html
x_refsource_MISC
x_transferred
https://jvn.jp/en/vu/JVNVU92898656/index.html
x_refsource_MISC
x_transferred
Hyperlink: https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.html
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://jvn.jp/en/vu/JVNVU92898656/index.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:vultures@jpcert.or.jp
Published At:26 Apr, 2021 | 01:15
Updated At:03 May, 2022 | 16:04

Improper following of a certificate's chain of trust vulnerability in DAP-1880AC firmware version 1.21 and earlier allows a remote authenticated attacker to gain root privileges via unspecified vectors.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

D-Link Corporation
dlink
>>dap-1880ac_firmware>>Versions up to 1.21(inclusive)
cpe:2.3:o:dlink:dap-1880ac_firmware:*:*:*:*:*:*:*:*
D-Link Corporation
dlink
>>dap-1880ac>>-
cpe:2.3:h:dlink:dap-1880ac:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-295Primarynvd@nist.gov
CWE ID: CWE-295
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://jvn.jp/en/vu/JVNVU92898656/index.htmlvultures@jpcert.or.jp
Third Party Advisory
https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.htmlvultures@jpcert.or.jp
Vendor Advisory
Hyperlink: https://jvn.jp/en/vu/JVNVU92898656/index.html
Source: vultures@jpcert.or.jp
Resource:
Third Party Advisory
Hyperlink: https://www.dlink-jp.com/support/release/jvnvu92898656_dap-1880ac.html
Source: vultures@jpcert.or.jp
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

313Records found

CVE-2025-11097
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 05:02
Updated-02 Oct, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_device_name command injection

A vulnerability has been found in D-Link DIR-823X 250416. Impacted is an unknown function of the file /goform/set_device_name. The manipulation of the argument mac leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11099
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 06:02
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X delete_prohibiting uci_del command injection

A vulnerability was determined in D-Link DIR-823X 250416. The impacted element is the function uci_del of the file /goform/delete_prohibiting. This manipulation of the argument delvalue causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2928
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.03% / 9.16%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 05:02
Updated-27 Feb, 2026 | 18:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 WLAN Encryption Configuration Endpoint formWlEncrypt sub_452CCC stack-based overflow

A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_452CCC of the file /boafrm/formWlEncrypt of the component WLAN Encryption Configuration Endpoint. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2929
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.02% / 4.89%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 05:32
Updated-27 Feb, 2026 | 18:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 Wireless Access Control Endpoint formWlAc sub_453140 stack-based overflow

A vulnerability was determined in D-Link DWR-M960 1.01.07. Impacted is the function sub_453140 of the file /boafrm/formWlAc of the component Wireless Access Control Endpoint. This manipulation of the argument submit-url causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2926
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.22%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 04:32
Updated-26 Feb, 2026 | 16:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 LTE Configuration Endpoint formLteSetup sub_4237AC stack-based overflow

A flaw has been found in D-Link DWR-M960 1.01.07. This affects the function sub_4237AC of the file /boafrm/formLteSetup of the component LTE Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-44959
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-47.06% / 97.72%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 00:00
Updated-18 Sep, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue found in D-Link DSL-3782 v.1.03 and before allows remote authenticated users to execute arbitrary code as root via the Router IP Address fields of the network settings page.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dsl-3782_firmwaredsl-3782n/adsl-3782_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2958
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.02% / 4.89%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 23:32
Updated-23 Feb, 2026 | 21:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 formWsc sub_457C5C stack-based overflow

A security vulnerability has been detected in D-Link DWR-M960 1.01.07. Affected is the function sub_457C5C of the file /boafrm/formWsc. Such manipulation of the argument save_apply leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-43960
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-6.19% / 90.96%
||
7 Day CHG~0.00%
Published-11 Oct, 2023 | 00:00
Updated-18 Sep, 2024 | 16:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in DLINK DPH-400SE FRU 2.2.15.8 allows a remote attacker to escalate privileges via the User Modify function in the Maintenance/Access function component.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dph-400sedph-400se_firmwaren/adph-400se_fru
CWE ID-CWE-269
Improper Privilege Management
CVE-2026-2883
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.02% / 4.89%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 20:02
Updated-23 Feb, 2026 | 19:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 formIpQoS sub_427D74 stack-based overflow

A vulnerability was determined in D-Link DWR-M960 1.01.07. Impacted is the function sub_427D74 of the file /boafrm/formIpQoS. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2882
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.22%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 20:02
Updated-23 Feb, 2026 | 19:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 formDosCfg sub_46385C stack-based overflow

A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_46385C of the file /boafrm/formDosCfg. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2023-43284
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-37.68% / 97.25%
||
7 Day CHG~0.00%
Published-05 Oct, 2023 | 00:00
Updated-19 Sep, 2024 | 20:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link Wireless MU-MIMO Gigabit AC1200 Router DIR-846 100A53DBR-Retail devices allow an authenticated remote attacker to execute arbitrary code via an unspecified manipulation of the QoS POST parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-846_firmwaredir-846n/adir-846_firmware
CVE-2026-2885
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.02% / 4.89%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 20:32
Updated-23 Feb, 2026 | 19:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 formIpv6Setup sub_469104 stack-based overflow

A security flaw has been discovered in D-Link DWR-M960 1.01.07. The impacted element is the function sub_469104 of the file /boafrm/formIpv6Setup. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2853
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.22%
||
7 Day CHG~0.00%
Published-20 Feb, 2026 | 19:02
Updated-24 Feb, 2026 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 System Log Configuration Endpoint formSysLog sub_462E14 stack-based overflow

A vulnerability was detected in D-Link DWR-M960 1.01.07. This affects the function sub_462E14 of the file /boafrm/formSysLog of the component System Log Configuration Endpoint. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2854
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.22%
||
7 Day CHG~0.00%
Published-20 Feb, 2026 | 19:02
Updated-24 Feb, 2026 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M960 NTP Configuration Endpoint formNtp sub_4611CC stack-based overflow

A flaw has been found in D-Link DWR-M960 1.01.07. This impacts the function sub_4611CC of the file /boafrm/formNtp of the component NTP Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m960_firmwaredwr-m960DWR-M960
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-11095
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 04:02
Updated-02 Oct, 2025 | 19:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X delete_offline_device command injection

A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/delete_offline_device. Performing manipulation of the argument delvalue results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11092
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 02:02
Updated-02 Oct, 2025 | 19:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_switch_settings sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_switch_settings. This manipulation of the argument port causes command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11100
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 06:32
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_wifi_blacklists uci_set command injection

A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the file /goform/set_wifi_blacklists. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10779
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.27% / 50.13%
||
7 Day CHG~0.00%
Published-22 Sep, 2025 | 03:02
Updated-25 Sep, 2025 | 20:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-935L HNAP1 sub_402280 stack-based overflow

A vulnerability was found in D-Link DCS-935L up to 1.13.01. The impacted element is the function sub_402280 of the file /HNAP1/. The manipulation of the argument HNAP_AUTH/SOAPAction results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-935ldcs-935l_firmwareDCS-935L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-11339
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.50% / 66.00%
||
7 Day CHG-0.02%
Published-06 Oct, 2025 | 16:32
Updated-19 Nov, 2025 | 21:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow

A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1_firmwaredi-7100g_c1DI-7100G C1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-9535
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.59%
||
7 Day CHG~0.00%
Published-01 Mar, 2020 | 23:03
Updated-04 Aug, 2024 | 10:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

fmwlan.c on D-Link DIR-615Jx10 devices has a stack-based buffer overflow via the formWlanSetup_Wizard webpage parameter when f_radius_ip1 is malformed.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-615jx10_firmwaredir-615jx10n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-11098
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 05:32
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_wifi_blacklists command injection

A vulnerability was found in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_wifi_blacklists. The manipulation of the argument macList results in command injection. The attack may be performed from remote. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-9377
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-76.64% / 98.96%
||
7 Day CHG~0.00%
Published-09 Jul, 2020 | 12:06
Updated-10 Nov, 2025 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-04-15||The impacted product is end-of-life and should be disconnected if still in use.

D-Link DIR-610 devices allow Remote Command Execution via the cmd parameter to command.php. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-610_firmwaredir-610n/aDIR-610 Devices
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-11338
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.54% / 67.95%
||
7 Day CHG-0.03%
Published-06 Oct, 2025 | 16:02
Updated-19 Nov, 2025 | 21:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow

A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1_firmwaredi-7100g_c1DI-7100G C1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-23754
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.26%
||
7 Day CHG~0.00%
Published-21 Jan, 2026 | 18:02
Updated-14 May, 2026 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View 8 IDOR Allows Credential Disclosure and Account Takeover

D-Link D-View 8 versions 2.0.1.107 and below contain an improper access control vulnerability in backend API endpoints. Any authenticated user can supply an arbitrary user_id value to retrieve sensitive credential data belonging to other users, including super administrators. The exposed credential material can be reused directly as a valid authentication secret, allowing full impersonation of the targeted account. This results in complete account takeover and full administrative control over the D-View system.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-View 8
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2025-11096
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG+0.11%
Published-28 Sep, 2025 | 04:32
Updated-02 Oct, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X diag_traceroute command injection

A flaw has been found in D-Link DIR-823X 250416. This issue affects some unknown processing of the file /goform/diag_traceroute. Executing manipulation of the argument target_addr can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11408
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.16% / 36.64%
||
7 Day CHG-0.01%
Published-07 Oct, 2025 | 20:32
Updated-19 Nov, 2025 | 20:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7001 MINI dbsrv.asp buffer overflow

A security vulnerability has been detected in D-Link DI-7001 MINI 24.04.18B1. The affected element is an unknown function of the file /dbsrv.asp. Such manipulation of the argument str leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7001mini-8gdi-7001mini-8g_firmwareDI-7001 MINI
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2020-9534
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.42% / 61.94%
||
7 Day CHG~0.00%
Published-01 Mar, 2020 | 23:03
Updated-04 Aug, 2024 | 10:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

fmwlan.c on D-Link DIR-615Jx10 devices has a stack-based buffer overflow via the formWlanSetup webpage parameter when f_radius_ip1 is malformed.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-615jx10_firmwaredir-615jx10n/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-2168
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.40%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeQuectel sub_419920 command injection

A flaw has been found in D-Link DWR-M921 1.1.50. This affects the function sub_419920 of the file /boafrm/formLtefotaUpgradeQuectel. This manipulation of the argument fota_url causes command injection. It is possible to initiate the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2193
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 27.23%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:02
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 set_jhttpd_info command injection

A vulnerability was detected in D-Link DI-7100G C1 24.04.18D1. Affected by this issue is the function set_jhttpd_info. Performing a manipulation of the argument usb_username results in command injection. Remote exploitation of the attack is possible.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1di-7100g_c1_firmwareDI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2194
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.89%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:32
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 start_proxy_client_email command injection

A flaw has been found in D-Link DI-7100G C1 24.04.18D1. This affects the function start_proxy_client_email. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1di-7100g_c1_firmwareDI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2169
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 26.28%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeFibocom command injection

A vulnerability has been found in D-Link DWR-M921 1.1.50. This impacts an unknown function of the file /boafrm/formLtefotaUpgradeFibocom. Such manipulation of the argument fota_url leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1624
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.02% / 5.19%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 22:02
Updated-23 Feb, 2026 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M961 formLtefotaUpgradeFibocom command injection

A security vulnerability has been detected in D-Link DWR-M961 1.1.47. The affected element is an unknown function of the file /boafrm/formLtefotaUpgradeFibocom. Such manipulation of the argument fota_url leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m961dwr-m961_firmwareDWR-M961
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-1625
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.02% / 5.19%
||
7 Day CHG~0.00%
Published-29 Jan, 2026 | 22:02
Updated-23 Feb, 2026 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M961 SMS Message formSmsManage sub_4250E0 command injection

A vulnerability was detected in D-Link DWR-M961 1.1.47. The impacted element is the function sub_4250E0 of the file /boafrm/formSmsManage of the component SMS Message. Performing a manipulation of the argument action_value results in command injection. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m961dwr-m961_firmwareDWR-M961
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10401
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.31% / 53.96%
||
7 Day CHG~0.00%
Published-14 Sep, 2025 | 15:32
Updated-24 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823x diag_ping command injection

A vulnerability was detected in D-Link DIR-823x up to 250416. The affected element is an unknown function of the file /goform/diag_ping. Performing manipulation of the argument target_addr results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823x
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10629
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.40%
||
7 Day CHG~0.00%
Published-18 Sep, 2025 | 00:32
Updated-22 Sep, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Simple Service Discovery Protocol Service cgibin ssdpcgi_main command injection

A vulnerability was determined in D-Link DIR-852 1.00CN B09. This issue affects the function ssdpcgi_main of the file htodcs/cgibin of the component Simple Service Discovery Protocol Service. Executing manipulation of the argument ST can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10034
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.20% / 41.77%
||
7 Day CHG~0.00%
Published-06 Sep, 2025 | 14:32
Updated-29 Sep, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-825 httpd ping6_response.cg get_ping6_app_stat buffer overflow

A vulnerability was found in D-Link DIR-825 1.08.01. This impacts the function get_ping6_app_stat of the file ping6_response.cg of the component httpd. Performing manipulation of the argument ping6_ipaddr results in buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-825dir-825_firmwareDIR-825
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-10634
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.13%
||
7 Day CHG~0.00%
Published-18 Sep, 2025 | 01:02
Updated-24 Sep, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X Environment Variable goahead sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. This manipulation of the argument terminal_addr/server_ip/server_port causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10628
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.94%
||
7 Day CHG~0.00%
Published-18 Sep, 2025 | 00:02
Updated-22 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Web Management hedwig.cgi command injection

A vulnerability was found in D-Link DIR-852 1.00CN B09. This vulnerability affects unknown code of the file /htdocs/cgibin/hedwig.cgi of the component Web Management Interface. Performing manipulation results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10666
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-6.37% / 91.10%
||
7 Day CHG~0.00%
Published-18 Sep, 2025 | 13:02
Updated-03 Feb, 2026 | 22:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-825 apply.cgi sub_4106d4 buffer overflow

A security flaw has been discovered in D-Link DIR-825 up to 2.10. Affected by this vulnerability is the function sub_4106d4 of the file apply.cgi. The manipulation of the argument countdown_time results in buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be exploited. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-825dir-825_firmwareDIR-825
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9913
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.22%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 17:31
Updated-16 Oct, 2024 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetRoute buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formSetRoute of the file /goform/formSetRoute. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9555
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.14% / 33.10%
||
7 Day CHG+0.03%
Published-06 Oct, 2024 | 14:31
Updated-08 Oct, 2024 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetEasy_Wizard buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-605L 2.13B01 BETA. Affected by this issue is the function formSetEasy_Wizard of the file /goform/formSetEasy_Wizard. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9558
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.33% / 56.17%
||
7 Day CHG+0.07%
Published-06 Oct, 2024 | 18:00
Updated-08 Oct, 2024 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetWanPPTP buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formSetWanPPTP of the file /goform/formSetWanPPTP. The manipulation of the argument webpage leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9566
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.18% / 39.16%
||
7 Day CHG+0.04%
Published-07 Oct, 2024 | 13:00
Updated-09 Oct, 2024 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formDeviceReboot buffer overflow

A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. This vulnerability affects the function formDeviceReboot of the file /goform/formDeviceReboot. The manipulation of the argument next_page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9535
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.38% / 59.53%
||
7 Day CHG+0.09%
Published-05 Oct, 2024 | 14:00
Updated-09 Oct, 2024 | 11:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formEasySetupWWConfig buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been declared as critical. Affected by this vulnerability is the function formEasySetupWWConfig of the file /goform/formEasySetupWWConfig. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9908
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.35% / 57.53%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 12:00
Updated-16 Oct, 2024 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetMACFilter buffer overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-619L B1 2.06. Affected is the function formSetMACFilter of the file /goform/formSetMACFilter. The manipulation of the argument curTime leads to buffer overflow. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9782
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.55%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 11:31
Updated-16 Oct, 2024 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formEasySetupWWConfig buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formEasySetupWWConfig of the file /goform/formEasySetupWWConfig. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9911
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.75%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 16:00
Updated-16 Oct, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetPortTr buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been classified as critical. This affects the function formSetPortTr of the file /goform/formSetPortTr. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9786
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.35% / 57.48%
||
7 Day CHG~0.00%
Published-10 Oct, 2024 | 13:00
Updated-16 Oct, 2024 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetLog buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. Affected by this issue is the function formSetLog of the file /goform/formSetLog. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9569
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.36% / 58.26%
||
7 Day CHG+0.08%
Published-07 Oct, 2024 | 15:00
Updated-09 Oct, 2024 | 13:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formEasySetPassword buffer overflow

A vulnerability has been found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this vulnerability is the function formEasySetPassword of the file /goform/formEasySetPassword. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9910
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.75%
||
7 Day CHG~0.00%
Published-13 Oct, 2024 | 14:31
Updated-16 Oct, 2024 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formSetPassword buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this issue is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')