Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-21595

Summary
Assigner-dell
Assigner Org ID-c550e75a-17ff-4988-97f0-544cde3820fe
Published At-16 Aug, 2021 | 22:00
Updated At-17 Sep, 2024 | 00:30
Rejected At-
Credits

Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:dell
Assigner Org ID:c550e75a-17ff-4988-97f0-544cde3820fe
Published At:16 Aug, 2021 | 22:00
Updated At:17 Sep, 2024 | 00:30
Rejected At:
▼CVE Numbering Authority (CNA)

Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.

Affected Products
Vendor
Dell Inc.Dell
Product
PowerScale OneFS
Versions
Affected
  • 8.2.x - 9.1.1.x
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.16.0MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Version: 3.1
Base score: 6.0
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dell.com/support/kbdoc/000190408
x_refsource_MISC
Hyperlink: https://www.dell.com/support/kbdoc/000190408
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dell.com/support/kbdoc/000190408
x_refsource_MISC
x_transferred
Hyperlink: https://www.dell.com/support/kbdoc/000190408
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:security_alert@emc.com
Published At:16 Aug, 2021 | 22:15
Updated At:25 Aug, 2021 | 00:43

Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.7MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Secondary3.16.0MEDIUM
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Primary2.04.6MEDIUM
AV:L/AC:L/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 6.7
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 6.0
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
Type: Primary
Version: 2.0
Base score: 4.6
Base severity: MEDIUM
Vector:
AV:L/AC:L/Au:N/C:P/I:P/A:P
CPE Matches

Dell Inc.
dell
>>emc_powerscale_onefs>>Versions from 9.0.0.0(inclusive) to 9.2.0(exclusive)
cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*
Dell Inc.
dell
>>emc_powerscale_onefs>>8.2.2
cpe:2.3:o:dell:emc_powerscale_onefs:8.2.2:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE-77Secondarysecurity_alert@emc.com
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-77
Type: Secondary
Source: security_alert@emc.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.dell.com/support/kbdoc/000190408security_alert@emc.com
Patch
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/000190408
Source: security_alert@emc.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

278Records found

CVE-2024-25953
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.10% / 27.33%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 18:27
Updated-09 Jan, 2025 | 16:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 9.4.0.x through 9.7.0.x contains an UNIX symbolic link (symlink) following vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to denial of service, information tampering.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2024-25952
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6||MEDIUM
EPSS-0.10% / 27.33%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 18:21
Updated-09 Jan, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains an UNIX symbolic link (symlink) following vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to denial of service, information tampering.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2024-22429
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.05% / 14.34%
||
7 Day CHG~0.00%
Published-17 May, 2024 | 15:20
Updated-30 Jan, 2025 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell BIOS contains an Improper Input Validation vulnerability. A local authenticated malicious user with admin privileges could potentially exploit this vulnerability, leading to arbitrary code execution.

Action-Not Available
Vendor-Dell Inc.
Product-latitude_3189_firmwarelatitude_5590latitude_12_rugged_extreme_7214latitude_5480latitude_5488_firmwarelatitude_3190_2-in-1latitude_5424_rugged_firmwareoptiplex_3050precision_5530_2-in-1_firmwareembedded_box_pc_3000_firmwarelatitude_5290_firmwarelatitude_13_3380latitude_5490_firmwarelatitude_3300optiplex_7450_all-in-one_firmwarelatitude_5488optiplex_7450_all-in-onelatitude_5480_firmwarelatitude_5288_firmwarelatitude_3190latitude_3189edge_gateway_3000latitude_5400wyse_7040_thin_clientlatitude_3390_2-in-1latitude_5280_firmwarewyse_5070embedded_box_pc_3000latitude_7285_2-in-1_firmwareoptiplex_3050_firmwarelatitude_7390_2-in-1_firmwareprecision_3520latitude_7290_firmwareprecision_3420_tower_firmwarelatitude_5414_rugged_firmwarelatitude_5400_firmwareoptiplex_5050_firmwarelatitude_3190_firmwareembedded_box_pc_5000precision_5820_towerprecision_3620_tower_firmwarelatitude_7424_rugged_extremelatitude_7480_firmwareprecision_7720_firmwareprecision_3620_towerprecision_7520latitude_7212_rugged_extreme_tablet_firmwarelatitude_7280latitude_7380_firmwarelatitude_5414_ruggedlatitude_7212_rugged_extreme_tabletlatitude_3180latitude_3190_2-in-1_firmwarelatitude_5424_ruggedlatitude_7280_firmwarelatitude_3300_firmwarelatitude_3180_firmwareprecision_3520_firmwarelatitude_7390_2-in-1edge_gateway_5000_firmwarelatitude_5288precision_5520edge_gateway_5000latitude_5290_2-in-1precision_5820_tower_firmwarelatitude_7285_2-in-1latitude_7390_firmwarelatitude_7490latitude_5290_2-in-1_firmwarelatitude_5290latitude_7290latitude_13_3380_firmwarelatitude_5420_ruggededge_gateway_3000_firmwarelatitude_5590_firmwareprecision_7720latitude_5490precision_7520_firmwarelatitude_5280precision_5530_2-in-1embedded_box_pc_5000_firmwarelatitude_5420_rugged_firmwarelatitude_7414_rugged_firmwareprecision_5520_firmwarewyse_5070_firmwarelatitude_3390_2-in-1_firmwarelatitude_5580latitude_7490_firmwareoptiplex_5050latitude_5580_firmwarelatitude_7390wyse_7040_thin_client_firmwarelatitude_7424_rugged_extreme_firmwareoptiplex_3050_all-in-one_firmwareoptiplex_3050_all-in-onelatitude_7380latitude_7414_ruggedprecision_3420_towerlatitude_12_rugged_extreme_7214_firmwarelatitude_7480CPG BIOSedge_gateway_3000_firmwareprecision_3620_towerlatitude_3180_firmwarelatitude_3189_firmwarelatitude_5280_firmwarelatitude_5424_firmwarelatitude_3300_firmwarelatitude_13_3380latitude_12_rugged_extreme_7214_firmwarelatitude_7212_rugged_extreme_tablet_firmwareprecision_3420_towerlatitude_3390_2-in-1wyse_5070latitude_7414_rugged_extreme_firmwarelatitude_5414_firmware
CWE ID-CWE-20
Improper Input Validation
CVE-2024-22453
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.03% / 5.66%
||
7 Day CHG~0.00%
Published-19 Mar, 2024 | 07:42
Updated-04 Feb, 2025 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge Server BIOS contains a heap-based buffer overflow vulnerability. A local high privileged attacker could potentially exploit this vulnerability to write to otherwise unauthorized memory.

Action-Not Available
Vendor-Dell Inc.
Product-xc730xd_firmwarenx3230_firmwarepoweredge_fc430_firmwarexc430_firmwarepoweredge_r730xdpoweredge_r530poweredge_r630poweredge_r630_firmwarepoweredge_m830_\(pe_vrtx\)poweredge_r730xd_firmwarepoweredge_t630_firmwarepoweredge_c6320_firmwarepoweredge_fc630_firmwarepoweredge_fc430poweredge_m630xc6320_firmwarexc730_firmwarepoweredge_m830_firmwarepoweredge_t430poweredge_r730poweredge_fc630nx3230poweredge_r930_firmwarepoweredge_m630_\(pe_vrtx\)_firmwarenx3330poweredge_r830_firmwarepoweredge_r430_firmwarepoweredge_fc830poweredge_m830_\(pe_vrtx\)_firmwarenx3330_firmwarepoweredge_c4130poweredge_r830xc430poweredge_fc830_firmwarexc6320poweredge_c6320poweredge_r730_firmwarexc730xc730xdpoweredge_c4130_firmwarepoweredge_t430_firmwarepoweredge_r530_firmwarepoweredge_t630xc630_firmwarepoweredge_r430poweredge_m830xc630poweredge_m630_\(pe_vrtx\)poweredge_r930poweredge_m630_firmwarePowerEdge Platform
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-5363
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.6||HIGH
EPSS-0.05% / 14.47%
||
7 Day CHG~0.00%
Published-10 Jun, 2020 | 20:40
Updated-16 Sep, 2024 | 20:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Select Dell Client Consumer and Commercial platforms include an issue that allows the BIOS Admin password to be changed through Dell's manageability interface without knowledge of the current BIOS Admin password. This could potentially allow an unauthorized actor, with physical access and/or OS administrator privileges to the device, to gain privileged access to the platform and the hard drive.

Action-Not Available
Vendor-Dell Inc.
Product-latitude_7300latitude_5401precision_7740_firmwareprecision_3541precision_3541_firmwarelatitude_5401_firmwareprecision_7540_firmwarelatitude_5500_firmwareprecision_3540_firmwarelatitude_5300_firmwarexps_13_9300xps_7390_2-in-1_firmwarelatitude_7300_firmwarelatitude_5500latitude_7400latitude_5400_firmwarelatitude_7200_2_in_1_firmwarelatitude_7220_firmwareprecision_7540precision_7740latitude_7220ex_rugged_extreme_tabletxps_7590_firmwarelatitude_7220ex_rugged_extreme_tablet_firmwarexps_7590latitude_7220latitude_7200_2_in_1latitude_5501latitude_5300latitude_7400_firmwareprecision_3540xps_13_9300_firmwarexps_7390_2-in-1latitude_5501_firmwarelatitude_5300_2-in-1latitude_5300_2-in-1_firmwarelatitude_5400Dell Client Consumer and Commercial platforms
CWE ID-CWE-158
Improper Neutralization of Null Byte or NUL Character
CVE-2020-29501
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.4||MEDIUM
EPSS-0.03% / 6.65%
||
7 Day CHG~0.00%
Published-05 Jan, 2021 | 21:40
Updated-16 Sep, 2024 | 16:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC PowerStore versions prior to 1.0.3.0.5.007 contain a Plain-Text Password Storage Vulnerability in PowerStore X & T environments. A locally authenticated attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.

Action-Not Available
Vendor-Dell Inc.
Product-emc_powerstoreemc_powerstore_firmwarePowerStore
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2022-34406
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.03% / 8.49%
||
7 Day CHG~0.00%
Published-16 Mar, 2023 | 11:00
Updated-26 Feb, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user with high Privileges may potentially exploit this vulnerability to perform arbitrary code execution or cause denial of service.

Action-Not Available
Vendor-Dell Inc.
Product-r750xa_firmwaret430_firmwarer6515_firmwaret350_firmwarefc430_firmwarem630_firmwaret550_firmwarer430nx3330r750xac6420r6515fc430r530_firmwarer930_firmwarer450r650_firmwarer6415t130_firmwarec6520_firmwaret440xe7420m630r640_firmwarer740r550_firmwarec4130_firmwarer830r940xar7515_firmwaret340_firmwarer240_firmwarer630_firmwarenx3230fc640_firmwarem830pr250fc630_firmwarer940xa_firmwarexe2420_firmwarenx3340t640_firmwarer940_firmwarexe7440r230_firmwarem830_firmwarec4140_firmwarec6320_firmwarexr12_firmwarem640pr750fc630r730xd_firmwarer7415r550r6415_firmwarer340xe8545r650nx430_firmwarefc640r630c4130r740xd2_firmwarer7425_firmwarer240c6420_firmwaret330_firmwaremx740cr7425r330_firmwarec6525t140r750xs_firmwarer330nx430r640nx440_firmwaremx840cm630pnx3340_firmwarer750xst630m640c6320r430_firmwarer650xsr350t150_firmwarer750_firmwaret150r6525mx840c_firmwarer740_firmwarer450_firmwarenx3240_firmwarec4140t630_firmwaret340t130t430r440_firmwarer530dss8440_firmwaremx740c_firmwarer250_firmwarer940r340_firmwarer7415_firmwarer840r730nx3240m830m640p_firmwarexe8545_firmwarer440r740xd2r7525_firmwarer6525_firmwarer730xdr540r230mx750c_firmwarer840_firmwarer740xd_firmwarer7525xe2420xr11_firmwaredss8440xr11m630p_firmwarefc830r350_firmwaret550xr12nx3330_firmwaremx750cnx440t640r830_firmwarer540_firmwarem830p_firmwaret350fc830_firmwaret140_firmwarexe7440_firmwarer730_firmwarexr2m640_firmwarer740xdr7515t330c6525_firmwarexe7420_firmwarer650xs_firmwaret440_firmwarexr2_firmwarer930nx3230_firmwarec6520PowerEdge Platform
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34383
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8.1||HIGH
EPSS-0.04% / 13.20%
||
7 Day CHG~0.00%
Published-31 Aug, 2022 | 20:05
Updated-16 Sep, 2024 | 23:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Edge Gateway 5200 (EGW) versions before 1.03.10 contain an operating system command injection vulnerability. A local malicious user may potentially exploit this vulnerability by using an SMI to bypass PMC mitigation and gain arbitrary code execution during SMM.

Action-Not Available
Vendor-Dell Inc.
Product-edge_gateway_5200edge_gateway_5200_firmwareEdge Gateway 5200
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-34432
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-0.14% / 35.44%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 16:40
Updated-19 May, 2025 | 16:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Hybrid Client below 1.8 version contains a gedit vulnerability. A guest attacker could potentially exploit this vulnerability, allowing deletion of user and some system files and folders.

Action-Not Available
Vendor-Dell Inc.
Product-hybrid_clientDell Hybrid Client (DHC)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-1212
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-1.26% / 78.54%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 17:00
Updated-17 Sep, 2024 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated remote code execution in iDRAC 6

The web-based diagnostics console in Dell EMC iDRAC6 (Monolithic versions prior to 2.91 and Modular all versions) contains a command injection vulnerability. A remote authenticated malicious iDRAC user with access to the diagnostics console could potentially exploit this vulnerability to execute arbitrary commands as root on the affected iDRAC system.

Action-Not Available
Vendor-Dell Inc.
Product-idrac6_monolithicidrac6_modulariDRAC6 (Modular)iDRAC6 (Monolithic)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-1244
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-1.52% / 80.52%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 17:00
Updated-16 Sep, 2024 | 16:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
iDRAC7/iDRAC8/iDrac9 contains a command injection vulnerability in the SNMP agent.

Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to execute arbitrary commands on the iDRAC where SNMP alerting is enabled.

Action-Not Available
Vendor-Dell Inc.
Product-idrac9_firmwareidrac7_firmwareidrac8_firmwareiDRAC8iDRAC9iDRAC7
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-4401
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.43% / 61.36%
||
7 Day CHG~0.00%
Published-05 Oct, 2023 | 17:12
Updated-19 Sep, 2024 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric Storage Software v1.4 (and earlier) contains an OS Command Injection Vulnerability in the CLI use of the ‘more’ command. A local or remote authenticated attacker could potentially exploit this vulnerability, leading to the ability to gain root-level access.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_storage_softwareDell SmartFabric Storage Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-9682
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-21.42% / 95.49%
||
7 Day CHG~0.00%
Published-22 Feb, 2017 | 05:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The SonicWall Secure Remote Access server (version 8.1.0.2-14sv) is vulnerable to two Remote Command Injection vulnerabilities in its web administrative interface. These vulnerabilities occur in the diagnostics CGI (/cgi-bin/diagnostics) component responsible for emailing out information about the state of the system. The application doesn't properly escape the information passed in the 'tsrDeleteRestartedFile' or 'currentTSREmailTo' variables before making a call to system(), allowing for remote command injection. Exploitation of this vulnerability yields shell access to the remote machine under the nobody user account.

Action-Not Available
Vendor-n/aDell Inc.
Product-sonicwall_secure_remote_access_servern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-9683
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-21.97% / 95.56%
||
7 Day CHG~0.00%
Published-22 Feb, 2017 | 05:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The SonicWall Secure Remote Access server (version 8.1.0.2-14sv) is vulnerable to a Remote Command Injection vulnerability in its web administrative interface. This vulnerability occurs in the 'extensionsettings' CGI (/cgi-bin/extensionsettings) component responsible for handling some of the server's internal configurations. The CGI application doesn't properly escape the information it's passed when processing a particular multi-part form request involving scripts. The filename of the 'scriptname' variable is read in unsanitized before a call to system() is performed - allowing for remote command injection. Exploitation of this vulnerability yields shell access to the remote machine under the nobody user account. This is SonicWall Issue ID 181195.

Action-Not Available
Vendor-n/aDell Inc.
Product-sonicwall_secure_remote_access_servern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-45104
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-3.16% / 86.40%
||
7 Day CHG~0.00%
Published-10 Feb, 2023 | 21:04
Updated-24 Mar, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unisphere for PowerMax vApp, VASA Provider vApp, and Solution Enabler vApp version 9.2.3.x contain a command execution vulnerability. A low privileged remote attacker could potentially exploit this vulnerability, leading to execute arbitrary commands on the underlying system.

Action-Not Available
Vendor-Dell Inc.
Product-unisphere_for_powermax_virtual_appliancesolutions_enabler_virtual_applianceevasa_provider_virtual_applianceUnisphere for PowerMax vApp
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-26331
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 8.63%
||
7 Day CHG~0.00%
Published-07 Mar, 2025 | 08:06
Updated-01 Jul, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.

Action-Not Available
Vendor-Dell Inc.
Product-latitude_3420optiplex_3000_thin_clientlatitude_5440wyse_5470_all-in-one_thin_clientoptiplex_7420_all-in-onelatitude_5450latitude_3440optiplex_5400_all-in-oneoptiplex_7410_all-in-onewyse_5070_thin_clientthinoswyse_5470_mobile_thin_clientWyse Proprietary OS (Modern ThinOS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-22472
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.04% / 8.77%
||
7 Day CHG+0.01%
Published-17 Mar, 2025 | 17:47
Updated-14 Jul, 2025 | 20:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of commands with elevated privileges.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-22473
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 8.52%
||
7 Day CHG+0.01%
Published-17 Mar, 2025 | 17:42
Updated-14 Jul, 2025 | 20:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-22476
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-5.5||MEDIUM
EPSS-0.26% / 49.21%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 16:08
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Storage Center - Dell Storage Manager, version(s) 20.1.20, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with adjacent network access could potentially exploit this vulnerability, leading to Remote execution.

Action-Not Available
Vendor-Dell Inc.
Product-Dell Storage Center - Dell Storage Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25951
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8||HIGH
EPSS-0.71% / 71.34%
||
7 Day CHG~0.00%
Published-09 Mar, 2024 | 05:56
Updated-31 Jan, 2025 | 16:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability exists in local RACADM. A malicious authenticated user could gain control of the underlying operating system.

Action-Not Available
Vendor-Dell Inc.
Product-idrac8Integrated Dell Remote Access Controller 8integrated_dell_remote_access_controller_8
CWE ID-CWE-1288
Improper Validation of Consistency within Input
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2016-9684
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.52% / 93.96%
||
7 Day CHG~0.00%
Published-22 Feb, 2017 | 05:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The SonicWall Secure Remote Access server (version 8.1.0.2-14sv) is vulnerable to a Remote Command Injection vulnerability in its web administrative interface. This vulnerability occurs in the 'viewcert' CGI (/cgi-bin/viewcert) component responsible for processing SSL certificate information. The CGI application doesn't properly escape the information it's passed in the 'CERT' variable before a call to system() is performed - allowing for remote command injection. Exploitation of this vulnerability yields shell access to the remote machine under the nobody user account.

Action-Not Available
Vendor-n/aDell Inc.
Product-sonicwall_secure_remote_access_servern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7922
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 80.83%
||
7 Day CHG~0.00%
Published-19 Aug, 2024 | 15:00
Updated-20 Aug, 2024 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DNS-1550-04 myMusic.cgi cgi_write_playlist command injection

A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240814 and classified as critical. Affected by this issue is the function cgi_audio_search/cgi_create_playlist/cgi_get_album_all_tracks/cgi_get_alltracks_editlist/cgi_get_artist_all_album/cgi_get_genre_all_tracks/cgi_get_tracks_list/cgi_set_airplay_content/cgi_write_playlist of the file /cgi-bin/myMusic.cgi. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link CorporationDell Inc.
Product-dns-340ldnr-202ldns-320lw_firmwaredns-327ldns-1200-05dns-321_firmwaredns-325dns-120dns-343dns-320l_firmwaredns-320dnr-326dns-726-4dns-120_firmwaredns-326_firmwaredns-315ldnr-322ldns-326dns-1200-05_firmwaredns-1100-4_firmwarednr-326_firmwaredns-343_firmwaredns-345_firmwarednr-202l_firmwaredns-1550-04dns-323_firmwaredns-320_firmwaredns-320lwdns-315l_firmwaredns-320ldns-323dns-1100-4dnr-322l_firmwaredns-325_firmwaredns-345dns-1550-04_firmwaredns-726-4_firmwaredns-340l_firmwaredns-321dns-327l_firmwareDNS-326DNR-326DNS-327LDNS-120DNR-202LDNS-321DNS-323DNS-340LDNS-320LWDNR-322LDNS-320LDNS-345DNS-1550-04DNS-1200-05DNS-325DNS-343DNS-315LDNS-726-4DNS-320DNS-1100-4dns-343_firmwarednr-202l_firmwaredns-320lw_firmwaredns-323_firmwaredns-320_firmwaredns-315l_firmwaredns-321_firmwaredns-320l_firmwarednr-322l_firmwaredns-325_firmwaredns-120_firmwaredns-326_firmwaredns-1550-04_firmwaredns-726-4_firmwaredns-1200-05_firmwaredns-340l_firmwaredns-1100-4_firmwarednr-326_firmwaredns-345_firmwaredns-327l_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-53290
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-8.4||HIGH
EPSS-1.24% / 78.44%
||
7 Day CHG+0.08%
Published-11 Dec, 2024 | 07:34
Updated-04 Feb, 2025 | 16:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS version 2408 contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to Command execution

Action-Not Available
Vendor-Dell Inc.
Product-thinosWyse Proprietary OS (Modern ThinOS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-49560
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.39% / 59.00%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 03:17
Updated-15 Nov, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-49557
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.39% / 58.94%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 03:26
Updated-15 Nov, 2024 | 17:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-42427
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.6||HIGH
EPSS-2.66% / 85.20%
||
7 Day CHG~0.00%
Published-10 Sep, 2024 | 07:39
Updated-20 Dec, 2024 | 14:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS versions 2402 and 2405, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. An unauthenticated attacker with physical access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-wyse_thinosWyse Proprietary OS (Modern ThinOS)wyse_proprietary_os
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-38486
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.57% / 67.73%
||
7 Day CHG~0.00%
Published-06 Sep, 2024 | 04:06
Updated-13 Sep, 2024 | 20:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.5.4 through 10.5.5.10 and 10.5.6.x , contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25946
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.24%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:00
Updated-25 Mar, 2025 | 14:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managervirtual_appliance_manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25955
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.24%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:05
Updated-27 Jan, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managerunisphere_for_powermax_virtual_appliancesolutions_enabler_virtual_applianceunisphere_for_powermax
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-39577
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.1||HIGH
EPSS-0.22% / 44.80%
||
7 Day CHG~0.00%
Published-26 Sep, 2024 | 17:06
Updated-25 Nov, 2024 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, versions 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability leading to code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-48830
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.05% / 14.26%
||
7 Day CHG+0.01%
Published-17 Mar, 2025 | 16:56
Updated-14 Jul, 2025 | 20:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-48017
Matching Score-6
Assigner-Dell
ShareView Details
Matching Score-6
Assigner-Dell
CVSS Score-6.5||MEDIUM
EPSS-0.07% / 21.50%
||
7 Day CHG+0.02%
Published-17 Mar, 2025 | 17:23
Updated-14 Jul, 2025 | 20:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-1783
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.08% / 24.10%
||
7 Day CHG~0.00%
Published-15 May, 2019 | 20:05
Updated-20 Nov, 2024 | 17:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco NX-OS Software Command Injection Vulnerability

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to execute arbitrary commands on the underlying Linux operating system with the privilege level of root. The vulnerability is due to insufficient validation of arguments passed to a specific CLI command on the affected device. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying Linux operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-nexus_5548pnexus_5624qnexus_5548upnexus_56128pnexus_5648qnexus_6001nexus_7000nx-osnexus_5696qnexus_5596upnexus_5672upnexus_5596tnexus_7700nexus_6004Cisco NX-OS Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2021-1488
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 21.73%
||
7 Day CHG~0.00%
Published-29 Apr, 2021 | 17:31
Updated-08 Nov, 2024 | 23:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software for Firepower 1000 and 2100 Series Appliances Command Injection Vulnerability

A vulnerability in the upgrade process of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to inject commands that could be executed with root privileges on the underlying operating system (OS). This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by uploading a crafted upgrade package file to an affected device. A successful exploit could allow the attacker to inject commands that could be executed with root privileges on the underlying OS.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-firepower_1010firepower_2140firepower_1140firepower_2120adaptive_security_appliance_softwarefirepower_2130firepower_1120firepower_1150firepower_2110firepower_threat_defenseCisco Adaptive Security Appliance (ASA) Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-29256
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.26% / 48.85%
||
7 Day CHG~0.00%
Published-25 May, 2022 | 21:20
Updated-23 Apr, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Possible vulnerability at 'npm install' time in sharp if an attacker has control over build environment

sharp is an application for Node.js image processing. Prior to version 0.30.5, there is a possible vulnerability in logic that is run only at `npm install` time when installing versions of `sharp` prior to the latest v0.30.5. If an attacker has the ability to set the value of the `PKG_CONFIG_PATH` environment variable in a build environment then they might be able to use this to inject an arbitrary command at `npm install` time. This is not part of any runtime code, does not affect Windows users at all, and is unlikely to affect anyone that already cares about the security of their build environment. This problem is fixed in version 0.30.5.

Action-Not Available
Vendor-sharp_projectlovell
Product-sharpsharp
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-0253
Matching Score-4
Assigner-Juniper Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Juniper Networks, Inc.
CVSS Score-7.8||HIGH
EPSS-0.44% / 62.21%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 19:37
Updated-16 Sep, 2024 | 22:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Junos OS: NFX Series: Local Command Execution Vulnerability in JDMD Leads to Privilege Escalation

NFX Series devices using Juniper Networks Junos OS are susceptible to a local command execution vulnerability thereby allowing an attacker to elevate their privileges via the Junos Device Management Daemon (JDMD) process. This issue affects Juniper Networks Junos OS on NFX Series 17.2 version 17.2R1 and later versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R2-S5, 18.4R3-S5; 19.1 versions prior to 19.1R1-S3; 19.2 version 19.1R2 and later versions prior to 19.2R3; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R2-S2. 19.4 versions 19.4R3 and above. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1. This issue does not affect the JDMD as used by Junos Node Slicing such as External Servers use in conjunction with Junos Node Slicing and In-Chassis Junos Node Slicing on MX480, MX960, MX2008, MX2010, MX2020.

Action-Not Available
Vendor-Juniper Networks, Inc.
Product-junosnfx150nfx250nfx350Junos OS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-0364
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
ShareView Details
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
CVSS Score-6.7||MEDIUM
EPSS-0.12% / 31.17%
||
7 Day CHG~0.00%
Published-02 Feb, 2021 | 23:00
Updated-03 Aug, 2024 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In mobile_log_d, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Product: Android; Versions: Android-10, Android-11; Patch ID: ALPS05458478; Issue ID: ALPS05458503.

Action-Not Available
Vendor-n/aGoogle LLC
Product-androidAndroid
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-0363
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
ShareView Details
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
CVSS Score-6.7||MEDIUM
EPSS-0.09% / 25.96%
||
7 Day CHG~0.00%
Published-02 Feb, 2021 | 23:01
Updated-03 Aug, 2024 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In mobile_log_d, there is a possible command injection due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Product: Android; Versions: Android-10, Android-11; Patch ID: ALPS05458478.

Action-Not Available
Vendor-n/aGoogle LLC
Product-androidAndroid
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-0356
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
ShareView Details
Matching Score-4
Assigner-Android (associated with Google Inc. or Open Handset Alliance)
CVSS Score-6.7||MEDIUM
EPSS-0.12% / 31.17%
||
7 Day CHG~0.00%
Published-02 Feb, 2021 | 23:01
Updated-03 Aug, 2024 | 15:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In netdiag, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Product: Android; Versions: Android-10, Android-11; Patch ID: ALPS05442014.

Action-Not Available
Vendor-n/aGoogle LLC
Product-androidAndroid
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-9127
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-6.7||MEDIUM
EPSS-0.11% / 30.60%
||
7 Day CHG~0.00%
Published-13 Nov, 2020 | 14:46
Updated-04 Aug, 2024 | 10:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Some Huawei products have a command injection vulnerability. Due to insufficient input validation, an attacker with high privilege may inject some malicious codes in some files of the affected products. Successful exploit may cause command injection.Affected product versions include:NIP6300 versions V500R001C30,V500R001C60;NIP6600 versions V500R001C30,V500R001C60;Secospace USG6300 versions V500R001C30,V500R001C60;Secospace USG6500 versions V500R001C30,V500R001C60;Secospace USG6600 versions V500R001C30,V500R001C60;USG9500 versions V500R001C30,V500R001C60.

Action-Not Available
Vendor-n/aHuawei Technologies Co., Ltd.
Product-nip6600secospace_usg6500_firmwarenip6300secospace_usg6500usg9500_firmwaresecospace_usg6600_firmwaresecospace_usg6300nip6600_firmwarenip6300_firmwareusg9500secospace_usg6600secospace_usg6300_firmwareNIP6300;NIP6600;Secospace USG6300;Secospace USG6500;Secospace USG6600;USG9500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2018-0481
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 13.46%
||
7 Day CHG~0.00%
Published-05 Oct, 2018 | 14:00
Updated-26 Nov, 2024 | 14:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Command Injection Vulnerabilities

A vulnerability in the CLI parser of Cisco IOS XE Software could allow an authenticated, local attacker to execute commands on the underlying Linux shell of an affected device with root privileges. The vulnerability exist because the affected software improperly sanitizes command arguments, failing to prevent access to certain internal data structures on an affected device. An attacker who has privileged EXEC mode (privilege level 15) access to an affected device could exploit these vulnerabilities on the device by executing CLI commands that contain custom arguments. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0217
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.18% / 40.39%
||
7 Day CHG~0.00%
Published-08 Mar, 2018 | 07:00
Updated-02 Dec, 2024 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the CLI of the Cisco StarOS operating system for Cisco ASR 5000 Series Aggregation Services Routers could allow an authenticated, local attacker to perform a command injection attack on an affected system. The vulnerability is due to insufficient validation of commands that are supplied to certain configurations in the CLI of the affected operating system. An attacker could exploit this vulnerability by injecting crafted arguments into a vulnerable CLI command for an affected system. A successful exploit could allow the attacker to insert and execute arbitrary commands in the CLI of the affected system. To exploit this vulnerability, the attacker would need to authenticate to an affected system by using valid administrator credentials. Cisco Bug IDs: CSCvg29441.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-asr_5700_firmwareasr_5500_firmwareasr_5000asr_5500asr_5000_firmwareasr_5700Cisco StarOS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0324
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.20% / 42.29%
||
7 Day CHG~0.00%
Published-17 May, 2018 | 03:00
Updated-29 Nov, 2024 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the CLI of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an authenticated, high-privileged, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command parameters in the CLI parser. An attacker could exploit this vulnerability by invoking a vulnerable CLI command with crafted malicious parameters. An exploit could allow the attacker to execute arbitrary commands with a non-root user account on the underlying Linux operating system of the affected device. Cisco Bug IDs: CSCvi09723.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-network_functions_virtualization_infrastructureCisco Enterprise NFV Infrastructure Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0477
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.05% / 13.46%
||
7 Day CHG~0.00%
Published-05 Oct, 2018 | 14:00
Updated-26 Nov, 2024 | 14:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Command Injection Vulnerabilities

A vulnerability in the CLI parser of Cisco IOS XE Software could allow an authenticated, local attacker to execute commands on the underlying Linux shell of an affected device with root privileges. The vulnerability exist because the affected software improperly sanitizes command arguments, failing to prevent access to certain internal data structures on an affected device. An attacker who has privileged EXEC mode (privilege level 15) access to an affected device could exploit these vulnerabilities on the device by executing CLI commands that contain custom arguments. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0224
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 22.55%
||
7 Day CHG~0.00%
Published-08 Mar, 2018 | 07:00
Updated-02 Dec, 2024 | 20:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the CLI of the Cisco StarOS operating system for Cisco ASR 5000 Series Aggregation Services Routers could allow an authenticated, local attacker to execute arbitrary commands with root privileges on an affected operating system. The vulnerability is due to insufficient validation of user-supplied input by the affected operating system. An attacker could exploit this vulnerability by authenticating to an affected system and injecting malicious arguments into a vulnerable CLI command. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected system. Cisco Bug IDs: CSCvg38807.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-starosasr_5000asr_5500asr_5700Cisco StarOS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-25619
Matching Score-4
Assigner-Profelis IT Consultancy
ShareView Details
Matching Score-4
Assigner-Profelis IT Consultancy
CVSS Score-3.8||LOW
EPSS-0.20% / 41.83%
||
7 Day CHG~0.00%
Published-30 Mar, 2022 | 14:55
Updated-03 Aug, 2024 | 04:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection to RCE

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in ping tool of Profelis IT Consultancy SambaBox allows AUTHENTICATED user to cause run arbitrary code. This issue affects: Profelis IT Consultancy SambaBox 4.0 version 4.0 and prior versions on x86.

Action-Not Available
Vendor-profelisProfelis IT Consultancy
Product-sambaboxSambaBox
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-6650
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.8||HIGH
EPSS-0.58% / 67.82%
||
7 Day CHG~0.00%
Published-22 May, 2017 | 01:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the Telnet CLI command of Cisco NX-OS System Software 7.1 through 7.3 running on Cisco Nexus Series Switches could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting crafted command arguments into the Telnet CLI command. An exploit could allow the attacker to read or write arbitrary files at the user's privilege level outside of the user's path. Cisco Bug IDs: CSCvb86771.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-nexus_5548upnexus_5596upnexus_5624qnexus_5596tnexus_5696qnexus_5672up-16gnx-osnexus_5648qnexus_5672upnexus_56128pCisco Nexus Series Switches
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-20665
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6||MEDIUM
EPSS-0.15% / 36.48%
||
7 Day CHG~0.00%
Published-06 Apr, 2022 | 18:13
Updated-06 Nov, 2024 | 16:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco StarOS Command Injection Vulnerability

A vulnerability in the CLI of Cisco StarOS could allow an authenticated, local attacker to elevate privileges on an affected device. This vulnerability is due to insufficient input validation of CLI commands. An attacker could exploit this vulnerability by sending crafted commands to the CLI. A successful exploit could allow the attacker to execute arbitrary code with the privileges of the root user. To exploit this vulnerability, an attacker would need to have valid administrative credentials on an affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-starosultra_cloud_coreasr_5500asr_5700Cisco ASR 5000 Series Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-20934
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6||MEDIUM
EPSS-0.04% / 10.86%
||
7 Day CHG~0.00%
Published-10 Nov, 2022 | 17:34
Updated-19 Nov, 2024 | 21:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the CLI of Cisco Firepower Threat Defense (FTD) Software and Cisco FXOS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system as root. This vulnerability is due to improper input validation for specific CLI commands. An attacker could exploit this vulnerability by injecting operating system commands into a legitimate command. A successful exploit could allow the attacker to escape the restricted command prompt and execute arbitrary commands on the underlying operating system. To successfully exploit this vulnerability, an attacker would need valid Administrator credentials.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-firepower_extensible_operating_systemfirepower_threat_defenseCisco Firepower Threat Defense SoftwareCisco Firepower Extensible Operating System (FXOS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-36198
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-6.7||MEDIUM
EPSS-0.69% / 70.87%
||
7 Day CHG~0.00%
Published-13 May, 2021 | 02:55
Updated-17 Sep, 2024 | 01:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection Vulnerability in Malware Remover

A command injection vulnerability has been reported to affect certain versions of Malware Remover. If exploited, this vulnerability allows remote attackers to execute arbitrary commands. This issue affects: QNAP Systems Inc. Malware Remover versions prior to 4.6.1.0. This issue does not affect: QNAP Systems Inc. Malware Remover 3.x.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-malware_removerMalware Remover
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next
Details not found