Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-48830

Summary
Assigner-dell
Assigner Org ID-c550e75a-17ff-4988-97f0-544cde3820fe
Published At-17 Mar, 2025 | 16:56
Updated At-26 Feb, 2026 | 19:09
Rejected At-
Credits

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:dell
Assigner Org ID:c550e75a-17ff-4988-97f0-544cde3820fe
Published At:17 Mar, 2025 | 16:56
Updated At:26 Feb, 2026 | 19:09
Rejected At:
▼CVE Numbering Authority (CNA)

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Affected Products
Vendor
Dell Inc.Dell
Product
SmartFabric OS10 Software
Default Status
unaffected
Versions
Affected
  • 10.5.4.x
  • 10.5.5.x
  • 10.5.6.x
  • 10.6.0.x
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

finder
Dell would like to thank n3k from TIANGONG Team of Legendsec at QI-ANXIN Group for reporting this issue.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.dell.com/support/kbdoc/en-us/000289970/dsa-2025-070-security-update-for-dell-networking-os10-vulnerabilities
vendor-advisory
https://www.dell.com/support/kbdoc/en-us/000293638/dsa-2025-069-security-update-for-dell-networking-os10-vulnerabilities
vendor-advisory
https://www.dell.com/support/kbdoc/en-us/000295014/dsa-2025-068-security-update-for-dell-networking-os10-vulnerabilities
vendor-advisory
https://www.dell.com/support/kbdoc/en-us/000294091/dsa-2025-079-security-update-for-dell-networking-os10-vulnerabilities
vendor-advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000289970/dsa-2025-070-security-update-for-dell-networking-os10-vulnerabilities
Resource:
vendor-advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000293638/dsa-2025-069-security-update-for-dell-networking-os10-vulnerabilities
Resource:
vendor-advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000295014/dsa-2025-068-security-update-for-dell-networking-os10-vulnerabilities
Resource:
vendor-advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000294091/dsa-2025-079-security-update-for-dell-networking-os10-vulnerabilities
Resource:
vendor-advisory
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:security_alert@emc.com
Published At:17 Mar, 2025 | 17:15
Updated At:14 Jul, 2025 | 20:29

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Dell Inc.
dell
>>smartfabric_os10>>Versions from 10.5.4.0(inclusive) to 10.5.4.14(exclusive)
cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Dell Inc.
dell
>>smartfabric_os10>>Versions from 10.5.5.0(inclusive) to 10.5.5.13(exclusive)
cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Dell Inc.
dell
>>smartfabric_os10>>Versions from 10.5.6.0(inclusive) to 10.5.6.8(exclusive)
cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Dell Inc.
dell
>>smartfabric_os10>>Versions from 10.6.0.0(inclusive) to 10.6.0.2(exclusive)
cpe:2.3:o:dell:smartfabric_os10:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarysecurity_alert@emc.com
CWE ID: CWE-77
Type: Primary
Source: security_alert@emc.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.dell.com/support/kbdoc/en-us/000289970/dsa-2025-070-security-update-for-dell-networking-os10-vulnerabilitiessecurity_alert@emc.com
Vendor Advisory
https://www.dell.com/support/kbdoc/en-us/000293638/dsa-2025-069-security-update-for-dell-networking-os10-vulnerabilitiessecurity_alert@emc.com
Vendor Advisory
https://www.dell.com/support/kbdoc/en-us/000294091/dsa-2025-079-security-update-for-dell-networking-os10-vulnerabilitiessecurity_alert@emc.com
Vendor Advisory
https://www.dell.com/support/kbdoc/en-us/000295014/dsa-2025-068-security-update-for-dell-networking-os10-vulnerabilitiessecurity_alert@emc.com
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000289970/dsa-2025-070-security-update-for-dell-networking-os10-vulnerabilities
Source: security_alert@emc.com
Resource:
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000293638/dsa-2025-069-security-update-for-dell-networking-os10-vulnerabilities
Source: security_alert@emc.com
Resource:
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000294091/dsa-2025-079-security-update-for-dell-networking-os10-vulnerabilities
Source: security_alert@emc.com
Resource:
Vendor Advisory
Hyperlink: https://www.dell.com/support/kbdoc/en-us/000295014/dsa-2025-068-security-update-for-dell-networking-os10-vulnerabilities
Source: security_alert@emc.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

375Records found

CVE-2025-26331
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.19% / 41.27%
||
7 Day CHG~0.00%
Published-07 Mar, 2025 | 08:06
Updated-26 Feb, 2026 | 19:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS 2411 and prior, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.

Action-Not Available
Vendor-Dell Inc.
Product-latitude_3420optiplex_3000_thin_clientlatitude_5440wyse_5470_all-in-one_thin_clientoptiplex_7420_all-in-onelatitude_5450latitude_3440optiplex_5400_all-in-oneoptiplex_7410_all-in-onewyse_5070_thin_clientthinoswyse_5470_mobile_thin_clientWyse Proprietary OS (Modern ThinOS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-22473
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.14% / 34.14%
||
7 Day CHG~0.00%
Published-17 Mar, 2025 | 17:42
Updated-26 Feb, 2026 | 19:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-22472
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.14% / 34.14%
||
7 Day CHG~0.00%
Published-17 Mar, 2025 | 17:47
Updated-26 Feb, 2026 | 19:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to execution of commands with elevated privileges.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-49560
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.30% / 53.96%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 03:17
Updated-15 Nov, 2024 | 17:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) a command injection vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-49557
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.32% / 55.73%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 03:26
Updated-15 Nov, 2024 | 17:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Softwaresmartfabric_os10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-23862
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.05% / 15.59%
||
7 Day CHG~0.00%
Published-16 Mar, 2026 | 17:28
Updated-02 Jun, 2026 | 19:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS 10 versions prior to ThinOS 2602_10.0573, contain an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.

Action-Not Available
Vendor-Dell Inc.
Product-thinosThinOS 10
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-4401
Matching Score-10
Assigner-Dell
ShareView Details
Matching Score-10
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.43% / 62.62%
||
7 Day CHG~0.00%
Published-05 Oct, 2023 | 17:12
Updated-19 Sep, 2024 | 18:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric Storage Software v1.4 (and earlier) contains an OS Command Injection Vulnerability in the CLI use of the ‘more’ command. A local or remote authenticated attacker could potentially exploit this vulnerability, leading to the ability to gain root-level access.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_storage_softwareDell SmartFabric Storage Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-27689
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.58%
||
7 Day CHG~0.00%
Published-12 Jun, 2025 | 20:36
Updated-26 Feb, 2026 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell iDRAC Tools, version(s) prior to 11.3.0.0, contain(s) an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-idrac_toolsiDRAC Tools
CWE ID-CWE-284
Improper Access Control
CVE-2025-24386
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.19% / 41.19%
||
7 Day CHG~0.00%
Published-28 Mar, 2025 | 02:19
Updated-26 Feb, 2026 | 19:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-32451
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-0.03% / 9.24%
||
7 Day CHG~0.00%
Published-06 Feb, 2024 | 07:46
Updated-07 Nov, 2024 | 21:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Display Manager application, version 2.1.1.17, contains a vulnerability that low privilege user can execute malicious code during installation and uninstallation

Action-Not Available
Vendor-Dell Inc.
Product-display_managerDell Display Manager
CWE ID-CWE-272
Least Privilege Violation
CWE ID-CWE-269
Improper Privilege Management
CVE-2023-32487
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.04% / 13.74%
||
7 Day CHG~0.00%
Published-16 Aug, 2023 | 13:28
Updated-08 Oct, 2024 | 19:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, 8.2.x - 9.5.0.x, contains an elevation of privilege vulnerability. A low privileged local attacker could potentially exploit this vulnerability, leading to denial of service, code execution and information disclosure.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-269
Improper Privilege Management
CVE-2025-46691
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.02% / 6.71%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 19:31
Updated-09 Mar, 2026 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PremierColor Panel Driver, versions prior to 1.0.0.1 A01, contains an Improper Access Control vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.

Action-Not Available
Vendor-Dell Inc.
Product-premiercolorPremierColor
CWE ID-CWE-284
Improper Access Control
CVE-2023-32477
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.11% / 28.97%
||
7 Day CHG~0.00%
Published-29 Sep, 2023 | 07:18
Updated-23 Sep, 2024 | 17:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Common Event Enabler 8.9.8.2 for Windows and prior, contain an improper access control vulnerability. A local low-privileged malicious user may potentially exploit this vulnerability to gain elevated privileges.

Action-Not Available
Vendor-Dell Inc.
Product-common_event_enablerCommon Event Enabler
CWE ID-CWE-284
Improper Access Control
CVE-2025-46685
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.02% / 5.86%
||
7 Day CHG~0.00%
Published-13 Jan, 2026 | 16:36
Updated-26 Feb, 2026 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SupportAssist OS Recovery, versions prior to 5.5.15.1, contain a Creation of Temporary File With Insecure Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-supportassist_os_recoverySupportAssist OS Recovery
CWE ID-CWE-378
Creation of Temporary File With Insecure Permissions
CVE-2025-46422
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.61%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 14:19
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-45376
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.01% / 1.84%
||
7 Day CHG~0.00%
Published-29 Sep, 2025 | 20:13
Updated-26 Feb, 2026 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Repository Manager (DRM), versions 3.4.7 and 3.4.8, contains an Improper Handling of Insufficient Permissions or Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-repository_managerDell Repository Manager (DRM)
CWE ID-CWE-280
Improper Handling of Insufficient Permissions or Privileges
CVE-2025-46369
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.02% / 5.19%
||
7 Day CHG~0.00%
Published-13 Nov, 2025 | 19:41
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Alienware Command Center 6.x (AWCC), versions prior to 6.10.15.0, contains an Insecure Temporary File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Privilege Escalation.

Action-Not Available
Vendor-Dell Inc.
Product-alienware_command_centerAlienware Command Center 6.x (AWCC)
CWE ID-CWE-377
Insecure Temporary File
CVE-2025-46423
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.61%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 14:14
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-32495
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.76%
||
7 Day CHG~0.00%
Published-16 Aug, 2023 | 13:00
Updated-08 Oct, 2024 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, 8.2.x-9.5.x, contains a exposure of sensitive information to an unauthorized Actor vulnerability. An authorized local attacker could potentially exploit this vulnerability, leading to escalation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2023-32450
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.1||MEDIUM
EPSS-0.06% / 19.98%
||
7 Day CHG~0.00%
Published-27 Jul, 2023 | 04:33
Updated-15 Oct, 2024 | 15:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Power Manager, Versions 3.3 to 3.14 contains an Improper Access Control vulnerability. A low-privileged malicious user may potentially exploit this vulnerability to perform arbitrary code execution with limited access.

Action-Not Available
Vendor-Dell Inc.
Product-power_managerDell Power Manager (DPM)
CWE ID-CWE-379
Creation of Temporary File in Directory with Insecure Permissions
CVE-2023-32460
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-0.04% / 11.98%
||
7 Day CHG~0.00%
Published-08 Dec, 2023 | 05:37
Updated-02 Aug, 2024 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.

Action-Not Available
Vendor-Dell Inc.
Product-poweredge_r7515poweredge_fc430poweredge_t140_firmwarepoweredge_t560_firmwarepoweredge_xr12poweredge_r7515_firmwarepoweredge_fc630poweredge_r760xa_firmwarepoweredge_xe7420poweredge_mx750c_firmwarepoweredge_r530poweredge_m640_\(pe_vrtx\)poweredge_m830_\(pe_vrtx\)emc_xc_core_xc650_firmwarenx3330emc_nx440_firmwarepoweredge_t630_firmwareemc_xc_core_xc940poweredge_r330dss_8440poweredge_xe7440_firmwarepoweredge_t130poweredge_xe9680poweredge_r430poweredge_r840_firmwarepoweredge_t150_firmwarepoweredge_r830poweredge_m630_\(pe_vrtx\)xc730_hyperconverged_appliancepoweredge_c6320poweredge_r350_firmwarepoweredge_r750_firmwarepoweredge_xr8610tpoweredge_r440poweredge_xr4510cpoweredge_c6615poweredge_m830poweredge_r340poweredge_fc640_firmwarepoweredge_c6320_firmwarepoweredge_r750xspoweredge_t640_firmwarepoweredge_r830_firmwarepoweredge_r740xd2poweredge_t550_firmwarepoweredge_xr7620_firmwarepoweredge_r240_firmwarepoweredge_fc830_firmwarenx3230poweredge_r730xdpoweredge_r230poweredge_t350poweredge_fc630_firmwareemc_xc_core_xc740xd2poweredge_r740poweredge_xr2xc_core_xc660_firmwarexc730xd_hyperconverged_appliancepoweredge_r230_firmwarepoweredge_r440_firmwarepoweredge_t150poweredge_r630_firmwarepoweredge_xe9680_firmwarepoweredge_r650xspoweredge_fc830xc430_hyperconverged_applianceemc_xc_core_xc740xd2_firmwarexc_core_xc760poweredge_r730xd_firmwarepoweredge_c6620_firmwareemc_storage_nx3240poweredge_mx840cemc_xc_core_xc740xd_firmwarepoweredge_mx740cpoweredge_r730poweredge_r7525poweredge_t130_firmwaredss_8440_firmwarepoweredge_r6615_firmwareemc_xc_core_xc750xa_firmwareemc_xc_core_xc640_firmwarepoweredge_fc430_firmwareemc_storage_nx3240_firmwarepoweredge_r540_firmwarepoweredge_r740xdpoweredge_r740_firmwarepoweredge_r6415nx430_firmwareemc_xc_core_xc750poweredge_r760xs_firmwarepoweredge_r740xd2_firmwarepoweredge_r940xaemc_xc_core_xc750xapoweredge_t330_firmwarepoweredge_r7625poweredge_r450_firmwarepoweredge_r640poweredge_r7425poweredge_r7615poweredge_r760xd2poweredge_r750xs_firmwarepoweredge_t440_firmwarepoweredge_r930_firmwarenx430poweredge_hs5620_firmwareemc_xc_core_xc6520poweredge_m830_firmwarepoweredge_r7615_firmwarepoweredge_r250poweredge_r6515_firmwarepoweredge_r240poweredge_hs5610_firmwarepoweredge_r430_firmwareemc_xc_core_xc6520_firmwarepoweredge_xr4510c_firmwarepoweredge_r730_firmwarepoweredge_xr8620t_firmwareemc_xc_core_6420_firmwareemc_xc_core_xc450_firmwarexc630_hyperconverged_appliancepoweredge_m640xc730xd_hyperconverged_appliance_firmwarepoweredge_xr8620tpoweredge_t630poweredge_r750poweredge_r650_firmwarepoweredge_m640_\(pe_vrtx\)_firmwarepoweredge_r930xc_core_xc760_firmwarexc6320_hyperconverged_appliance_firmwarepoweredge_xe8640poweredge_t640poweredge_c6520_firmwareemc_xc_core_xc940_firmwareemc_storage_nx3340_firmwarepoweredge_r550_firmwareemc_xc_core_xc750_firmwarexc6320_hyperconverged_appliancepoweredge_r760xd2_firmwarepoweredge_c4140_firmwarexc_core_xc660poweredge_r250_firmwarepoweredge_r760_firmwarepoweredge_r550poweredge_mx840c_firmwarepoweredge_r660_firmwarepoweredge_c6525_firmwarepoweredge_c6525emc_xc_core_xc650emc_xc_core_xc740xdpoweredge_r6625_firmwarepoweredge_r6415_firmwarepoweredge_m830_\(pe_vrtx\)_firmwarepoweredge_r330_firmwarepoweredge_m630xc730_hyperconverged_appliance_firmwarepoweredge_c6615_firmwareemc_xc_core_xc640poweredge_t430_firmwareemc_xc_core_6420poweredge_xe7420_firmwarepoweredge_c6420_firmwarepoweredge_r7415_firmwarepoweredge_fc640poweredge_xe2420_firmwarepoweredge_r7415poweredge_r660poweredge_c4140poweredge_r940_firmwareemc_xc_core_xcxr2_firmwarepoweredge_xr11_firmwarexc430_hyperconverged_appliance_firmwarepoweredge_r860poweredge_r650poweredge_r650xs_firmwarepoweredge_r740xd_firmwarepoweredge_xr11poweredge_t140poweredge_xr12_firmwarepoweredge_xr8610t_firmwarepoweredge_c6620poweredge_xr4520cpoweredge_r7625_firmwarepoweredge_r760xapoweredge_xe9640_firmwareemc_xc_core_xc7525_firmwarepoweredge_t560emc_xc_core_xcxr2poweredge_mx740c_firmwarepoweredge_xr7620poweredge_xr5610_firmwarepoweredge_r640_firmwarepoweredge_t440nx3330_firmwarepoweredge_xr4520c_firmwarepoweredge_r940xa_firmwarepoweredge_r630poweredge_c4130_firmwarepoweredge_r7525_firmwarepoweredge_t330nx440poweredge_mx760c_firmwarepoweredge_r660xspoweredge_r6525poweredge_xe8545_firmwarepoweredge_c4130poweredge_r6615poweredge_mx760cpoweredge_xe9640poweredge_xe8545emc_xc_core_xc7525poweredge_r940poweredge_r750xapoweredge_r540poweredge_t550poweredge_m640_firmwarepoweredge_r660xs_firmwarepoweredge_hs5620poweredge_t340_firmwarepoweredge_r340_firmwarepoweredge_t430poweredge_xr2_firmwarepoweredge_r6515poweredge_xe2420poweredge_r760poweredge_r530_firmwareemc_xc_core_xc450poweredge_r6525_firmwarepoweredge_mx750cpoweredge_c6420poweredge_xe7440poweredge_r960poweredge_m630_firmwarepoweredge_r350emc_storage_nx3340poweredge_xe8640_firmwarepoweredge_r750xa_firmwarepoweredge_r840poweredge_r960_firmwarepoweredge_r760xspoweredge_c6520poweredge_m630_\(pe_vrtx\)_firmwarepoweredge_t340poweredge_xr5610poweredge_r450poweredge_hs5610poweredge_t350_firmwarexc630_hyperconverged_appliance_firmwarepoweredge_r860_firmwarepoweredge_r6625nx3230_firmwarepoweredge_r7425_firmwarePowerEdge Platform
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2025-43885
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.05% / 14.68%
||
7 Day CHG~0.00%
Published-10 Sep, 2025 | 15:52
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution.

Action-Not Available
Vendor-Dell Inc.
Product-powerprotect_data_managerPowerProtect Data Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-43914
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.5||HIGH
EPSS-0.01% / 3.40%
||
7 Day CHG~0.00%
Published-07 Oct, 2025 | 17:43
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain BoostFS for Linux Ubuntu systems of Feature Release versions 7.7.1.0 through 8.3.0.15, LTS2025 release version 8.3.1.0, LTS2024 release versions 7.13.1.0 through 7.13.1.30, LTS 2023 release versions 7.10.1.0 through 7.10.1.60, contain an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.

Action-Not Available
Vendor-Dell Inc.
Product-data_domain_operating_systemPowerProtect Data Domain BoostFS for Linux Ubuntu Feature ReleasePowerProtect Data Domain BoostFS for Linux Ubuntu LTS2025PowerProtect Data Domain BoostFS for Linux Ubuntu LTS2024PowerProtect Data Domain BoostFS for Linux Ubuntu LTS2023
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2025-43990
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-0.01% / 2.97%
||
7 Day CHG~0.00%
Published-05 Nov, 2025 | 17:01
Updated-26 Feb, 2026 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Command Monitor (DCM), versions prior to 10.12.3.28, contains an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of Privileges.

Action-Not Available
Vendor-Dell Inc.
Product-command_monitorCommand Monitor (DCM)
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2025-43939
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.45%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 14:10
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.4 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-43725
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.02% / 5.53%
||
7 Day CHG~0.00%
Published-10 Sep, 2025 | 15:56
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Manager, Generic Application Agent, version(s) 19.19 and 19.20, contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution.

Action-Not Available
Vendor-Dell Inc.
Product-PowerProtect Data Manager
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2025-43882
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 7.78%
||
7 Day CHG~0.00%
Published-27 Aug, 2025 | 13:51
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS 10, versions prior to 2508_10.0127, contains an Unverified Ownership vulnerability. A local low-privileged attacker could potentially exploit this vulnerability leading to Unauthorized Access.

Action-Not Available
Vendor-Dell Inc.
Product-pro_max_16_pluspro_16_plus_pb16250latitude_5440pro_max_14latitude_3420latitude_5540wyse_5070_thin_clientlatitude_3440precision_3280latitude_3450optiplex_all-in-one_7410pro_14_pc14250optiplex_3000_tcoptiplex_5400_all-in-onewyse_5470_all-in-one_thin_clientoptiplex_all-in-one_7420thinospro_rugged_13_ra13250optiplex_micro_plus_7010pro_24_all-in-onewyse_5070_extended_thin_clientpro_tower_qct1250pro_rugged_14_rb14250pro_slim_low_sffoptiplex_7020pro_16_pc16250latitude_5450latitude_5530latitude_5550wyse_5470_mtclatitude_3330precision_3260_compactlatitude_5520ThinOS 10
CWE ID-CWE-283
Unverified Ownership
CVE-2025-43942
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.45%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 14:23
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-43730
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.4||HIGH
EPSS-0.10% / 27.18%
||
7 Day CHG~0.00%
Published-27 Aug, 2025 | 13:57
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell ThinOS 10, versions prior to 2508_10.0127, contains an Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability. A local unauthenticated user could potentially exploit this vulnerability leading to Elevation of Privileges and Information disclosure.

Action-Not Available
Vendor-Dell Inc.
Product-pro_max_16_pluspro_16_plus_pb16250latitude_5440pro_max_14latitude_3420latitude_5540wyse_5070_thin_clientlatitude_3440precision_3280latitude_3450optiplex_all-in-one_7410pro_14_pc14250optiplex_3000_tcoptiplex_5400_all-in-onewyse_5470_all-in-one_thin_clientoptiplex_all-in-one_7420thinospro_rugged_13_ra13250optiplex_micro_plus_7010pro_24_all-in-onewyse_5070_extended_thin_clientpro_tower_qct1250pro_rugged_14_rb14250pro_slim_low_sffoptiplex_7020pro_16_pc16250latitude_5450latitude_5530latitude_5550wyse_5470_mtclatitude_3330precision_3260_compactlatitude_5520ThinOS 10
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2025-43887
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7||HIGH
EPSS-0.01% / 3.43%
||
7 Day CHG~0.00%
Published-10 Sep, 2025 | 15:59
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Manager, version(s) 19.19 and 19.20, Hyper-V contain(s) an Incorrect Default Permissions vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerprotect_data_managerPowerProtect Data Manager
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2025-43888
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-0.03% / 9.28%
||
7 Day CHG~0.00%
Published-10 Sep, 2025 | 15:42
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Manager, Hyper-V, version(s) 19.19 and 19.20, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Unauthorized access.

Action-Not Available
Vendor-Dell Inc.
Product-powerprotect_data_managerPowerProtect Data Manager
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2025-43941
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.07% / 20.37%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 13:57
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability to execute arbitrary command with root privileges. This vulnerability only affects systems without a valid license install.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-43993
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.02% / 5.31%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 19:38
Updated-16 Jan, 2026 | 17:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution.

Action-Not Available
Vendor-Dell Inc.
Product-latitutde_5450pro_rugged_14_rb14250precision_3490latitude_7030_rugged_extreme_tablet_firmwarelatitude_7030_rugged_extreme_tabletmobile_precision_3591_firmwareprecision_3590_firmwarelatitude_7450_firmwarelatitutde_5450_firmwarelatitude_5350_firmwarelatitude_5550latitude_5550_firmwareprecision_3590pro_rugged_14_rb14250_firmwarepro_rugged_13_ra13250_firmwareprecision_3490_firmwarelatitude_7350_detachable_firmwarelatitude_7350_detachablelatitude_7350mobile_precision_3591pro_rugged_13_ra13250latitude_7650_firmwarelatitude_9450_2-in-1latitude_7450latitude_7350_firmwarelatitude_7650latitude_5350latitude_9450_2-in-1_firmwareWireless 5932e
CWE ID-CWE-428
Unquoted Search Path or Element
CVE-2025-43940
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 9.45%
||
7 Day CHG~0.00%
Published-30 Oct, 2025 | 14:05
Updated-26 Feb, 2026 | 16:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and Prior, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-38738
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.04% / 13.84%
||
7 Day CHG+0.03%
Published-14 Aug, 2025 | 14:36
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SupportAssist for Home PCs Installer exe version(s) 4.8.2.29006 and prior, contain(s) an Incorrect Privilege Assignment vulnerability in the Installer. A low privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-supportassist_for_home_pcsSupportAssist for Home PCs
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2025-38743
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.03% / 8.11%
||
7 Day CHG~0.00%
Published-21 Aug, 2025 | 18:46
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell iDRAC Service Module (iSM), versions prior to 6.0.3.0, contains a Buffer Access with Incorrect Length Value vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code execution and Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-emc_idrac_service_moduleiDRAC Service Module (iSM)
CWE ID-CWE-805
Buffer Access with Incorrect Length Value
CVE-2025-38747
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.06% / 20.09%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 19:48
Updated-26 Feb, 2026 | 17:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SupportAssist OS Recovery, versions prior to 5.5.14.0, contain a Creation of Temporary File With Insecure Permissions vulnerability. A local authenticated attacker could potentially exploit this vulnerability, leading to Elevation of Privileges.

Action-Not Available
Vendor-Dell Inc.
Product-supportassist_os_recoverySupportAssist OS Recovery
CWE ID-CWE-378
Creation of Temporary File With Insecure Permissions
CVE-2025-36612
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.04% / 13.84%
||
7 Day CHG+0.03%
Published-14 Aug, 2025 | 14:42
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SupportAssist for Business PCs, version(s) 4.5.3 and prior, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-supportassist_for_business_pcsSupportAssist for Business PCs
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2025-36613
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-2.8||LOW
EPSS-0.05% / 17.10%
||
7 Day CHG+0.03%
Published-14 Aug, 2025 | 14:46
Updated-18 Aug, 2025 | 18:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SupportAssist for Home PCs versions 4.6.3 and prior and SupportAssist for Business PCs versions 4.5.3 and prior, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to unauthorized access.

Action-Not Available
Vendor-Dell Inc.
Product-supportassist_for_business_pcssupportassist_for_home_pcsSupportAssist for Home PCs
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2025-36611
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-0.05% / 16.76%
||
7 Day CHG~0.00%
Published-30 Jul, 2025 | 16:18
Updated-26 Feb, 2026 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Encryption and Dell Security Management Server, versions prior to 11.11.0, contain an Improper Link Resolution Before File Access ('Link Following') Vulnerability. A local malicious user could potentially exploit this vulnerability, leading to privilege escalation.

Action-Not Available
Vendor-Dell Inc.
Product-encryptionsecurity_management_serverSecurity Management ServerEncryption
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2025-36606
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.15% / 34.94%
||
7 Day CHG~0.00%
Published-04 Aug, 2025 | 14:09
Updated-26 Feb, 2026 | 17:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and prior, contain(s) an OS Command Injection Vulnerability in its svc_nfssupport utility. An authenticated attacker could potentially exploit this vulnerability, escaping the restricted shell and execute arbitrary operating system commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-36568
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.01% / 0.52%
||
7 Day CHG~0.00%
Published-17 Apr, 2026 | 08:12
Updated-20 Apr, 2026 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerProtect Data Domain BoostFS for client of Feature Release versions 7.7.1.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.50, contain an insufficiently protected credentials vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to credential exposure. The attacker may be able to use the exposed credentials to access the system with privileges of the compromised account.

Action-Not Available
Vendor-Dell Inc.
Product-data_domain_operating_systemPowerProtect Data Domain BoostFS
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2023-32458
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-0.06% / 20.03%
||
7 Day CHG~0.00%
Published-27 Sep, 2023 | 15:52
Updated-23 Sep, 2024 | 20:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell AppSync, versions 4.4.0.0 to 4.6.0.0 including Service Pack releases, contains an improper access control vulnerability in Embedded Service Enabler component. A local malicious user could potentially exploit this vulnerability during installation leading to a privilege escalation.

Action-Not Available
Vendor-Dell Inc.ELAN Microelectronics Corporation
Product-appsyncDell EMC AppSync
CWE ID-CWE-284
Improper Access Control
CVE-2025-36564
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.07% / 21.93%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:41
Updated-26 Feb, 2026 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Encryption Admin Utilities versions prior to 11.10.2 contain an Improper Link Resolution vulnerability. A local malicious user could potentially exploit this vulnerability, leading to privilege escalation.

Action-Not Available
Vendor-Dell Inc.
Product-encryptionEncryption Admin Utilities
CWE ID-CWE-61
UNIX Symbolic Link (Symlink) Following
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2023-32479
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.04% / 13.61%
||
7 Day CHG~0.00%
Published-06 Feb, 2024 | 08:09
Updated-22 Aug, 2024 | 19:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Encryption, Dell Endpoint Security Suite Enterprise, and Dell Security Management Server versions prior to 11.9.0 contain privilege escalation vulnerability due to improper ACL of the non-default installation directory. A local malicious user could potentially exploit this vulnerability by replacing binaries in installed directory and taking reverse shell of the system leading to Privilege Escalation.

Action-Not Available
Vendor-Microsoft CorporationDell Inc.
Product-windowssecurity_management_serverencryptionendpoint_security_suite_enterpriseDell Security Management Server (Windows)Dell Endpoint Security Suite EnterpriseDell Encryptionsecurity_management_serverencryptionendpoint_security_suite_enterprise
CWE ID-CWE-284
Improper Access Control
CVE-2025-36607
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-7.8||HIGH
EPSS-0.15% / 34.94%
||
7 Day CHG~0.00%
Published-04 Aug, 2025 | 14:12
Updated-26 Feb, 2026 | 17:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell Unity, version(s) 5.5 and prior, contain(s) an OS Command Injection Vulnerability in its svc_nas utility. An authenticated attacker could potentially exploit this vulnerability, escaping the restricted shell and execute arbitrary operating system commands with root privileges.

Action-Not Available
Vendor-Dell Inc.
Product-unity_operating_environmentUnity
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-32486
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-6.7||MEDIUM
EPSS-0.06% / 18.76%
||
7 Day CHG~0.00%
Published-16 Aug, 2023 | 13:24
Updated-08 Oct, 2024 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS 9.5.x version contain a privilege escalation vulnerability. A low privilege local attacker could potentially exploit this vulnerability, leading to escalation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-250
Execution with Unnecessary Privileges
CVE-2025-36609
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-2.5||LOW
EPSS-0.04% / 12.79%
||
7 Day CHG~0.00%
Published-30 Jul, 2025 | 18:14
Updated-06 Aug, 2025 | 14:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell SmartFabric OS10 Software, versions prior to 10.6.0.5, contains a Use of Hard-coded Password vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-smartfabric_os10SmartFabric OS10 Software
CWE ID-CWE-259
Use of Hard-coded Password
CVE-2025-32747
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-5.3||MEDIUM
EPSS-0.01% / 1.48%
||
7 Day CHG~0.00%
Published-22 May, 2026 | 13:02
Updated-22 May, 2026 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerFlex Manager, version(s) <=4.6.2, contain(s) an Incorrect Privilege Assignment vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.

Action-Not Available
Vendor-Dell Inc.
Product-powerflex_appliance_intelligent_catalogpowerflex_rackpowerflex_managerPowerFlex Manager (Appliance)PowerFlex Manager (Rack)PowerFlex Manager
CWE ID-CWE-266
Incorrect Privilege Assignment
CVE-2025-32753
Matching Score-8
Assigner-Dell
ShareView Details
Matching Score-8
Assigner-Dell
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 16.70%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 13:46
Updated-11 Jul, 2025 | 12:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell PowerScale OneFS, versions 9.5.0.0 through 9.10.0.1, contains an improper neutralization of special elements used in an SQL command ('SQL injection') vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to denial of service, information disclosure, and information tampering.

Action-Not Available
Vendor-Dell Inc.
Product-powerscale_onefsPowerScale OneFS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 7
  • 8
  • Next
Details not found