Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.
CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution when a malicious project file is loaded into the application by a valid user.
A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file.
A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product.
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80.
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file.
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when placing a specific DLL file.
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)
A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.
A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.
A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0)
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0.
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could result in remote code execution when an authenticated user executes a saved project file that has been tampered by a malicious actor.
A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause malicious code execution when opening the project file.
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.
A CWE-287: Improper Authentication vulnerability exists that could allow remote code execution when a malicious file is uploaded. Affected Product: C-Bus Toolkit (V1.15.9 and prior), C-Gate Server (V2.11.7 and prior)
A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
A CWE-427: Uncontrolled Search Path Element vulnerability exists in GP-Pro EX,V4.09.250 and prior, that could cause local code execution with elevated privileges when installing the software.
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.
A CWE-787: Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247, that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.