Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-22806

Summary
Assigner-schneider
Assigner Org ID-076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At-11 Feb, 2022 | 17:40
Updated At-03 Aug, 2024 | 18:51
Rejected At-
Credits

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:schneider
Assigner Org ID:076d1eb6-cfab-4401-b34d-6dfc2a413bdb
Published At:11 Feb, 2022 | 17:40
Updated At:03 Aug, 2024 | 18:51
Rejected At:
▼CVE Numbering Authority (CNA)

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

Affected Products
Vendor
n/a
Product
spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
Versions
Affected
  • spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
Problem Types
TypeCWE IDDescription
CWECWE-669CWE-669: Incorrect Resource Transfer Between Spheres
Type: CWE
CWE ID: CWE-669
Description: CWE-669: Incorrect Resource Transfer Between Spheres
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01
x_refsource_MISC
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01
x_refsource_MISC
x_transferred
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cybersecurity@se.com
Published At:11 Feb, 2022 | 18:15
Updated At:22 Feb, 2022 | 18:48

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.5HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Schneider Electric SE
schneider-electric
>>spacelynk_firmware>>Versions up to 2.6.1(inclusive)
cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>spacelynk>>-
cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>wiser_for_knx_firmware>>Versions up to 2.6.1(inclusive)
cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>wiser_for_knx>>-
cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>fellerlynk_firmware>>Versions up to 2.6.1(inclusive)
cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>fellerlynk>>-
cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-669Primarycybersecurity@se.com
CWE ID: CWE-669
Type: Primary
Source: cybersecurity@se.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01cybersecurity@se.com
Broken Link
Patch
Vendor Advisory
Hyperlink: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01
Source: cybersecurity@se.com
Resource:
Broken Link
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

81Records found

CVE-2021-22798
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.29% / 52.07%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)

Action-Not Available
Vendor-n/a
Product-conext_comboxconext_combox_firmwareConext� ComBox (All Versions)
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2017-9965
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.8||MEDIUM
EPSS-1.88% / 82.39%
||
7 Day CHG~0.00%
Published-02 Jan, 2018 | 03:00
Updated-17 Sep, 2024 | 03:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.

Action-Not Available
Vendor-
Product-pelco_videoxpertPelco VideoXpert Enterprise
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-9960
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.65%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error provides more information than should be available to an unauthenticated user.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-22732
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-3.9||LOW
EPSS-0.12% / 31.07%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)

Action-Not Available
Vendor-Schneider Electric SE
Product-ecostruxure_power_commissionEcoStruxure Power Commission
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2017-6032
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.46% / 63.07%
||
7 Day CHG~0.00%
Published-30 Jun, 2017 | 02:35
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modbus_firmwaremodbusSchneider Electric Modicon Modbus Protocol
CWE ID-CWE-358
Improperly Implemented Security Check for Standard
CWE ID-CWE-657
Violation of Secure Design Principles
CVE-2020-7519
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.64%
||
7 Day CHG~0.00%
Published-23 Jul, 2020 | 20:51
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.

Action-Not Available
Vendor-n/a
Product-easergy_builderEasergy Builder (Version 1.4.7.2 and older)
CWE ID-CWE-521
Weak Password Requirements
CVE-2011-4036
Matching Score-8
Assigner-CERT/CC
ShareView Details
Matching Score-8
Assigner-CERT/CC
CVSS Score-5||MEDIUM
EPSS-0.51% / 65.22%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vijeo_historiancitectscada_reportscitecthistoriann/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-6407
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.38% / 58.48%
||
7 Day CHG+0.16%
Published-11 Jul, 2024 | 09:07
Updated-01 Aug, 2024 | 21:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device.

Action-Not Available
Vendor-
Product-whc-5918awhc-5918a_firmwareWiser Home Controller WHC-5918A
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6851
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.44% / 62.40%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:55
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6852
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.35% / 56.59%
||
7 Day CHG~0.00%
Published-20 Nov, 2019 | 22:01
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6845
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.21% / 42.75%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:49
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.

Action-Not Available
Vendor-n/a
Product-tsxmrpc001m_firmwaretsxmrpc002m_firmwaretsxmrpp384ktsxmfpp002m_firmwaremodicon_m580_firmwaretsxmrpc448k_firmwaretsxmrpf008mtsxmrpp384k_firmwaretsxmcpc002m_firmwaretsxmrpf004mtsxmrpc768ktsxmrpc01m7tsxmrpp224kmodicon_m580tsxmrpc01m7_firmwaretsxmfp064p2tsxmrpc003m_firmwaretsxmrpc001mtsxmfpp224ktsxmrpc002mtsxmfpp004mtsxmfpp001m_firmwaretsxmrpc768k_firmwaretsxmfpp001mtsxmrpp224k_firmwaretsxmrpc007m_firmwaretsxmfpp512k_firmwaretsxmfpp224k_firmwaretsxmfp0128p2tsxmrpc007mtsxmcpc002mmodicon_m340tsxmfpp384ktsxmrpf008m_firmwaretsxmcpc512ktsxmfp0128p2_firmwaretsxmcpc512k_firmwaretsxmfpp512ktsxmrpf004m_firmwaretsxmfp064p2_firmwaretsxmrpc003mtsxmfpp002mtsxmfpp384k_firmwaretsxmrpc448ktsxmfpp004m_firmwaremodicon_m340_firmwareModicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2019-6806
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.02%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 20:04
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus.

Action-Not Available
Vendor-n/a
Product-modicon_quantummodicon_quantum_firmwaremodicon_m580_firmwaremodicon_premium_firmwaremodicon_premiummodicon_m340modicon_m340_firmwaremodicon_m580Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
CVE-2019-6859
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.34% / 56.27%
||
7 Day CHG~0.00%
Published-22 Apr, 2020 | 18:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

Action-Not Available
Vendor-n/a
Product-tsx_ety_x103_firmwarebmx_noe_0100140_noc_78x00140_noe_771x1bmx_noe_0110tsx_ety_x103bmx_noc_0401_firmware140_cpu6x_firmwarebmx_p34x140_noc_78x00_firmware140_noe_771x1_firmware140_cpu6xtsx_p57xbmx_p34x_firmwarebmx_noe_0110_firmware140_noc_77101_firmwarebmx_noc_0401tsx_p57x_firmware140_noc_77101bmx_noe_0100_firmwareModicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications)
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2019-6850
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:54
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6836
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.28% / 50.95%
||
7 Day CHG~0.00%
Published-17 Sep, 2019 | 19:14
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file.

Action-Not Available
Vendor-n/a
Product-meg6260-0415_firmwaremeg6260-0410meg6501-0001_firmwaremeg6501-0002meg6260-0410_firmwaremeg6501-0001meg6260-0415meg6501-0002_firmwareU.motion Servers (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, and MEG6260-0415 - U.motion KNX Server Plus, Touch 1)
CWE ID-CWE-863
Incorrect Authorization
CVE-2015-0997
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.60% / 68.51%
||
7 Day CHG~0.00%
Published-29 Mar, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.

Action-Not Available
Vendor-n/aSchneider Electric SEAVEVA
Product-wonderware_intouch_2014aveva_edgen/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22749
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.36% / 57.11%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.

Action-Not Available
Vendor-n/a
Product-modicon_x80_bmxnor0200h_rtu_firmwaremodicon_x80_bmxnor0200h_rtuModicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22721
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.69%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:41
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22785
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.10%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists that could cause sensitive information of files located in the web root directory to leak when an attacker sends a HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)

Action-Not Available
Vendor-n/a
Product-tsxp575634140noc78x00_firmware140noe771x1tsxety5103140cpu65150tsxp574634_firmwarebmxnoc0401_firmwaretsxp575634_firmwarebmxnoe0110_firmware140noe771x1_firmwaretsxp574634tsxp576634modicon_m340_bmxp342020bmxnoe0100_firmwaretsxety4103_firmwarebmxnoc0401tsxp576634_firmwarebmxnor0200h_rtumodicon_m340_bmxp342020_firmware140noc77101_firmwarebmxnoe0100140cpu65150_firmwarebmxnor0200h_rtu_firmwaretsxety4103140noc77101bmxnoe0110140noc78x00tsxety5103_firmwareModicon M340 CPUs: BMXP34 (Versions prior to V3.40), Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOC0401, BMXNOR0200H RTU (All Versions), Modicon Premium Processors with integrated Ethernet (Copro): TSXP574634, TSXP575634, TSXP576634 (All Versions), Modicon Quantum Processors with Integrated Ethernet (Copro): 140CPU65xxxxx (All Versions), Modicon Quantum Communication Modules: 140NOE771x1, 140NOC78x00, 140NOC77101 (All Versions), Modicon Premium Communication Modules: TSXETY4103, TSXETY5103 (All Versions)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22774
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 34.07%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 10:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques.

Action-Not Available
Vendor-n/a
Product-evlink_city_evc1s22p4evlink_parking_evf2evlink_parking_evf2_firmwareevlink_parking_ev.2_firmwareevlink_parking_evw2evlink_city_evc1s22p4_firmwareevlink_city_evc1s7p4_firmwareevlink_smart_wallbox_evb1a_firmwareevlink_smart_wallbox_evb1aevlink_parking_evw2_firmwareevlink_parking_ev.2evlink_city_evc1s7p4EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )
CWE ID-CWE-916
Use of Password Hash With Insufficient Computational Effort
CVE-2021-22815
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.25% / 48.09%
||
7 Day CHG~0.00%
Published-28 Jan, 2022 | 19:09
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Action-Not Available
Vendor-n/a
Product-single-phase_symmetragalaxy_g9kchupdpm138h-5upd60f6fk1pdpm277hpd40e5ek20-mpd40l6fk1-msymmetra_px_20galaxy_gvmsapd60g6fk1gutor_gvxgalaxy_3500network_management_card_2_firmwarepdpm150g6fpdrppnx10pdpb150g6fpmm500-alaxgutor_sxwpdpm150l6fpdpm175g6hapc_rack_power_distribution_unitspd60l6fk1pdpm288g6hnetwork_management_card_3pdpm138h-rpdrppnx10mpd40f6fk1-mrack_automatic_transfer_switchessmart-upspd40h5ek20-mnetwork_management_card_2symmetra_px_160pmm400-alaxsymmetra_px_40symmetra_px_48netbotz_nbrk0250pmm400-alagalaxy_g7xnetwork_management_card_3_firmwarepdpm144fpmm400-cubgalaxy_gfcgalaxy_rpp_grppip2x84ap9922_battery_management_systemsymmetra_px_100symmetra_px_500galaxy_gcxsagalaxy_gvxtssymmetra_px_250symmetra_px_96pmm500-cubpd40g6fk1-mgalaxy_gvmtspmm500-alapdpm72f-5un/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2021-22804
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.49% / 64.56%
||
7 Day CHG~0.00%
Published-11 Feb, 2022 | 17:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_system_data_collectorInteractive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22702
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.14% / 35.16%
||
7 Day CHG~0.00%
Published-19 Feb, 2021 | 15:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion8650powerlogic_ion7700_firmwarepowerlogic_ion8400_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion8300_firmwarepowerlogic_ion7400_firmwarepowerlogic_ion7650_firmwarepowerlogic_ion7700powerlogic_ion8600powerlogic_ion8800powerlogic_ion8500_firmwarepowerlogic_ion8600_firmwarepowerlogic_ion8500powerlogic_ion8300powerlogic_ion9000_firmwarepowerlogic_ion7300_firmwarepowerlogic_ion9000powerlogic_ion8400powerlogic_ion7300powerlogic_ion8800_firmwarepowerlogic_ion7400powerlogic_ion7650powerlogic_ion8650_firmwarePowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-7541
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.31% / 53.84%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:52
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.

Action-Not Available
Vendor-n/a
Product-140noc78100140cpu65150140noc78000_firmwaretsxp575634_firmware140noc78000bmxnoe0110_firmwaretsxp574634modicon_m340_bmxp3420102clmodicon_m340_bmxp3420302_firmware140noc78100_firmwaremodicon_m340_bmxp342000modicon_m340_bmxp3420302cl_firmwaremodicon_m340_bmxp341000140noe77111_firmwaremodicon_m340_bmxp342020_firmware140noc77101_firmwaremodicon_m340_bmxp3420102_firmware140noc77101bmxnoe0110tsxety5103_firmwaremodicon_m340_bmxp3420102cl_firmwaretsxety5103tsxp574634_firmwarebmxnoc0401_firmware140noe77111modicon_m340_bmxp3420302clmodicon_m340_bmxp3420302modicon_m340_bmxp342020bmxnoe0100_firmwaretsxp576634modicon_m340_bmxp341000_firmwaretsxety4103_firmwarebmxnoc0401tsxp576634_firmwaremodicon_m340_bmxp342000_firmwarebmxnoe0100140cpu65150_firmwaremodicon_m340_bmxp3420102tsxety4103tsxp575634Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
CWE ID-CWE-425
Direct Request ('Forced Browsing')
CVE-2020-7510
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-16 Jun, 2020 | 19:44
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow attacker to obtain private keys.

Action-Not Available
Vendor-n/a
Product-easergy_t300easergy_t300_firmwareEasergy T300 (Firmware version 1.5.2 and older)
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2019-6849
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.32% / 54.66%
||
7 Day CHG~0.00%
Published-29 Oct, 2019 | 14:53
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module.

Action-Not Available
Vendor-n/a
Product-modicon_bmenoc_0321_firmwaremodicon_m580_firmwaremodicon_bmenoc_0321modicon_bmenoc_0311_firmwaremodicon_bmenoc_0311modicon_m580Modicon M580, Modicon BMENOC 0311, Modicon BMENOC 0321
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2022-30236
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.51% / 65.58%
||
7 Day CHG~0.00%
Published-02 Jun, 2022 | 22:45
Updated-16 Sep, 2024 | 23:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)

Action-Not Available
Vendor-
Product-wiser_smart_eer21000wiser_smart_eer21001_firmwarewiser_smart_eer21000_firmwarewiser_smart_eer21001Wiser Smart
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2004-0872
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-1.14% / 77.57%
||
7 Day CHG~0.00%
Published-13 Feb, 2005 | 05:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Opera does not prevent cookies that are sent over an insecure channel (HTTP) from also being sent over a secure channel (HTTPS/SSL) in the same domain, which could allow remote attackers to steal cookies and conduct unauthorized activities, aka "Cross Security Boundary Cookie Injection."

Action-Not Available
Vendor-n/aOpera
Product-opera_browsern/a
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2023-44104
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.5||HIGH
EPSS-0.07% / 21.63%
||
7 Day CHG~0.00%
Published-11 Oct, 2023 | 11:52
Updated-18 Sep, 2024 | 15:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Broadcast permission control vulnerability in the Bluetooth module.Successful exploitation of this vulnerability may affect service confidentiality.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-harmonyosemuiHarmonyOSEMUI
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2023-44100
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.5||HIGH
EPSS-0.07% / 21.63%
||
7 Day CHG~0.00%
Published-11 Oct, 2023 | 11:47
Updated-18 Sep, 2024 | 15:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Broadcast permission control vulnerability in the Bluetooth module.Successful exploitation of this vulnerability may affect service confidentiality.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-harmonyosemuiHarmonyOSEMUI
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2020-6862
Matching Score-4
Assigner-ZTE Corporation
ShareView Details
Matching Score-4
Assigner-ZTE Corporation
CVSS Score-5.3||MEDIUM
EPSS-13.27% / 93.89%
||
7 Day CHG~0.00%
Published-17 Jan, 2020 | 17:47
Updated-04 Aug, 2024 | 09:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

V6.0.10P2T2 and V6.0.10P2T5 of F6x2W product are impacted by Information leak vulnerability. Unauthorized users could log in directly to obtain page information without entering a verification code.

Action-Not Available
Vendor-ZTE Corporation
Product-f6x2wf6x2w_firmwareF6x2W
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
  • Previous
  • 1
  • 2
  • Next
Details not found