A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < 2.15.1), RUGGEDCOM ROX MX5000RE (All versions < 2.15.1), RUGGEDCOM ROX RX1400 (All versions < 2.15.1), RUGGEDCOM ROX RX1500 (All versions < 2.15.1), RUGGEDCOM ROX RX1501 (All versions < 2.15.1), RUGGEDCOM ROX RX1510 (All versions < 2.15.1), RUGGEDCOM ROX RX1511 (All versions < 2.15.1), RUGGEDCOM ROX RX1512 (All versions < 2.15.1), RUGGEDCOM ROX RX1524 (All versions < 2.15.1), RUGGEDCOM ROX RX1536 (All versions < 2.15.1), RUGGEDCOM ROX RX5000 (All versions < 2.15.1). Affected devices do not properly validate user input, making them susceptible to command injection. An attacker with access to either the shell or the web CLI with administrator privileges could access the underlying operating system as the root user.
Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected system allows to upload JSON objects that are deserialized to Java objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a maliciously crafted serialized Java object. This could allow the attacker to execute arbitrary code on the device with root privileges.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.11), Teamcenter Active Workspace V5.0 (All versions < V5.0.10), Teamcenter Active Workspace V5.1 (All versions < V5.1.6), Teamcenter Active Workspace V5.2 (All versions < V5.2.3). The application contains an unsafe unzipping pattern that could lead to a zip path traversal attack. This could allow and attacker to execute a remote shell with admin rights.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.4, 8.6.0.9, 8.5.0.13, 8.3.0.16, 6.5.4.20, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.
A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) version(s): Aruba Instant 6.4.x.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x.x: 6.5.4.18 and below; Aruba Instant 8.5.x.x: 8.5.0.11 and below; Aruba Instant 8.6.x.x: 8.6.0.6 and below; Aruba Instant 8.7.x.x: 8.7.1.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.
A vulnerability has been identified in Mendix SAML Module (All versions < V2.1.2). The configuration of the SAML module does not properly check various restrictions and validations imposed by an identity provider. This could allow a remote authenticated attacker to escalate privileges.
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.
A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.
Lodash versions prior to 4.17.21 are vulnerable to Command Injection via the template function.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with valid authentication at the RMI interface could be able to gain remote code execution through an unsecured file upload. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device.
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The bulk import feature of the affected systems allow a privileged user to upload files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application is vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected devices are vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockGeneralSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProjectUserRights' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.