Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-33736

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Oct, 2021 | 09:49
Updated At-03 Aug, 2024 | 23:58
Rejected At-
Credits

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Oct, 2021 | 09:49
Updated At:03 Aug, 2024 | 23:58
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

Affected Products
Vendor
Siemens AGSiemens
Product
SINEC NMS
Versions
Affected
  • All versions < V1.0 SP2 Update 1
Problem Types
TypeCWE IDDescription
CWECWE-89CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Type: CWE
CWE ID: CWE-89
Description: CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Oct, 2021 | 10:15
Updated At:18 Oct, 2021 | 17:53

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). A privileged authenticated attacker could execute arbitrary commands in the local database by sending crafted requests to the webserver of the affected application.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>sinec_nms>>Versions before 1.0(exclusive)
cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_nms>>1.0
cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_nms>>1.0
cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*
Siemens AG
siemens
>>sinec_nms>>1.0
cpe:2.3:a:siemens:sinec_nms:1.0:sp2:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-89Primaryproductcert@siemens.com
CWE ID: CWE-89
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdfproductcert@siemens.com
Patch
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-163251.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

4399Records found

CVE-2021-33721
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-5.08% / 89.82%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2). The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authenticated remote attacker with administrative privileges could exploit this vulnerability to execute arbitrary code on the system with system privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinec_network_management_systemSINEC NMS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-33712
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.25% / 47.98%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML Module (All versions < V2.1.2). The configuration of the SAML module does not properly check various restrictions and validations imposed by an identity provider. This could allow a remote authenticated attacker to escalate privileges.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML Module
CWE ID-CWE-345
Insufficient Verification of Data Authenticity
CVE-2021-31887
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-3.40% / 87.43%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “PWD/XPWD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0016)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-31888
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-3.40% / 87.43%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “MKD/XMKD” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0018)

Action-Not Available
Vendor-Siemens AG
Product-talon_tc_compactdesigo_pxm20-edesigo_pxc22.1-e.dapogee_pxc_compactdesigo_pxc001-e.d_firmwareapogee_modular_equiment_controller_firmwaredesigo_pxc12-e.dapogee_pxc_compact_firmwaredesigo_pxc200-e.d_firmwareapogee_modular_equiment_controllerdesigo_pxc100-e.dapogee_modular_building_controllerdesigo_pxc001-e.dapogee_pxc_modular_firmwaretalon_tc_modular_firmwaretalon_tc_modulardesigo_pxc22.1-e.d_firmwaredesigo_pxc50-e.dapogee_modular_building_controller_firmwaredesigo_pxc12-e.d_firmwaredesigo_pxc22-e.ddesigo_pxc22-e.d_firmwaredesigo_pxc00-u_firmwarenucleus_readystart_v3desigo_pxc00-e.ddesigo_pxc100-e.d_firmwaredesigo_pxc200-e.ddesigo_pxc00-e.d_firmwaredesigo_pxc50-e.d_firmwarenucleus_netdesigo_pxc64-utalon_tc_compact_firmwaredesigo_pxc36.1-e.d_firmwaredesigo_pxc64-u_firmwaredesigo_pxc128-udesigo_pxc00-uapogee_pxc_modulardesigo_pxm20-e_firmwaredesigo_pxc36.1-e.ddesigo_pxc128-u_firmwarenucleus_source_codeTALON TC Compact (BACnet)Desigo PXC64-UDesigo PXC00-UNucleus Source CodeAPOGEE PXC Compact (BACnet)APOGEE MEC (PPC) (P2 Ethernet)Nucleus NETDesigo PXC001-E.DDesigo PXC100-E.DDesigo PXC12-E.DAPOGEE MBC (PPC) (BACnet)Desigo PXC22.1-E.DTALON TC Modular (BACnet)Nucleus ReadyStart V3APOGEE MEC (PPC) (BACnet)Desigo PXC00-E.DAPOGEE MBC (PPC) (P2 Ethernet)Desigo PXC50-E.DAPOGEE PXC Compact (P2 Ethernet)Desigo PXC36.1-E.DAPOGEE PXC Modular (P2 Ethernet)Desigo PXC22-E.DDesigo PXC200-E.DDesigo PXM20-EAPOGEE PXC Modular (BACnet)Desigo PXC128-U
CWE ID-CWE-170
Improper Null Termination
CWE ID-CWE-787
Out-of-bounds Write
CVE-2017-5712
Matching Score-8
Assigner-Intel Corporation
ShareView Details
Matching Score-8
Assigner-Intel Corporation
CVSS Score-7.2||HIGH
EPSS-2.45% / 85.23%
||
7 Day CHG~0.00%
Published-21 Nov, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.

Action-Not Available
Vendor-ASUS (ASUSTeK Computer Inc.)Siemens AGIntel Corporation
Product-rog_strix_z270g_gaming_firmwareh110-plus_firmwareh170m-plus\/brsimatic_ipc627dprime_h110m-ptuf_z270_mark_2rog_strix_z270h_gaming\/k1prime_j3355i-cb150i_pro_gaming\/aurasimatic_ipc827ch110m-a\/dp_firmwaresimatic_ipc477d_firmwareq170t_firmwareb250m-f_plush110m-ksh110m-a_d3ex-b150m-v5rog_strix_b250i_gaming_firmwareh170_pro_gamingsimotion_p320-4strooper_b150_d3_firmwareh110s2b150m-dtuf_z370-plus_gaming_firmwareh110m-ts_firmwaresimatic_ipc647d_firmwareb150-asimatic_ipc477db150m-plus_d3_firmwarerog_maximus_viii_hero_firmwarerog_strix_z270f_gamingrog_maximus_viii_ranger_firmwareb150m-v_plus_firmwareprime_q270m-ch110-plush110s2_firmwareh110m-e_firmwareprime_h110m2\/fpt_firmwaresabertooth_z170_mark_1h110m-c\/hdmi_firmwaresinumerik_pcu50.5-p_firmwaretuf_z370-pro_gaming_firmwarerog_maximus_viii_hero_alpha_firmwarerog_maximus_ix_hero_firmwarez170-krog_strix_b250g_gaming_firmwarerog_strix_z370-f_gamingb150m-ah110m-aex-b250m-v5z170-prosimatic_ipc477eb150m-k_d3prime_h110m2_firmwarerog_maximus_viii_formulaprime_b250m-dsimatic_field_pg_m3_firmwarerog_maximus_ix_extremesimatic_ipc677cb150m-k_firmwareq170s1_firmwareex-b150m-v3_firmwareprime_b250m-jb150m-a_d3_firmwarez170m-e_d3z170-k_firmwarepio-b150m_firmwarerog_strix_h270i_gaming_firmwareh170m-plush110m-ks_r1_firmwareex-b250-v7b150m-plusz170-ar_firmwareh110m-plusb150m-v_plush110m-kex-b150-v7_firmwareh110m-a_d3_firmwarerog_strix_b250h_gaming_firmwareh110m-c\/br_firmwarez170m-plus\/brprime_h270-plus_firmwareprime_h110m2\/fptprime_z270m-plus\/br_firmwareh110t-a_firmwareh110i-plus_firmwaresimatic_ipc627d_firmwaresimatic_field_pg_m3prime_z270-kh170i-pro_firmwaresimatic_field_pg_m4simatic_ipc627ch170i-prob150m-plus_d3z170-premium_firmwaresabertooth_z170_mark_1_firmwareb150m-f_plush170m-e_d3z170-eb150-pro_firmwarepio-b150mrog_maximus_ix_codeprime_b250-plus_firmwareh110m-c_firmwarerog_maximus_x_hero_firmwaresimatic_itp1000simatic_ipc427d_firmwareh110m-e\/m.2_firmwareprime_h110m2rog_maximus_x_formularog_maximus_x_formula_firmwareh110m-d\/exper\/sib150_pro_gaming\/aura_firmwaremanageability_engine_firmwarerog_maximus_ix_herorog_strix_z270i_gamingh170-plus_d3_firmwareex-b150m-v_firmwareq170m-cm-brog_strix_z370-g_gamingprime_z270-arb150-pro_d3rog_strix_z270h_gamingh110m-cs\/br_firmwarerog_strix_z370-i_gamingrog_strix_z370-h_gaming_firmwareh110m-d_firmwaresabertooth_z170_sb150_pro_gamingh110m-a\/m.2q270m-cm-asimatic_ipc847c_firmwareh110m-rh170-pro\/usb_3.1_firmwareq170m2_firmwareb150m-kprime_z270m-plus_firmwareh110m-a_firmwareex-h110m-v3_firmwareh110m-k_x_firmwarez170m-e_d3_firmwareh170_pro_gaming_firmwareb150m-k_d3_firmwarerog_strix_z270f_gaming_firmwarerog_strix_b250f_gamingh110m-cs\/brq170s1ex-b250-v7_firmwaresabertooth_z170_s_firmwarerog_strix_b250h_gamingh110m-d\/exper\/si_firmwareex-b150m-v5_firmwareprime_b250m-d_firmwareh110m-p\/dvib150i_pro_gaming\/aura_firmwaresimatic_ipc647db150m-f_plus_firmwareh110m-ks_r1h110m-c\/ps_firmwareb150-proprime_h270-proex-h110m-v_firmwareex-b250m-v3rog_strix_z270g_gamingrog_maximus_ix_formula_firmwarerog_maximus_viii_gene_firmwareprime_z270-p_firmwareex-h110m-v3h110m-c2\/tf_firmwarez170-p_firmwareq270-sactive_management_technology_firmwaresimatic_ipc427e_firmwarez170m-plustrooper_h110_d3z170-deluxe_firmwaresimatic_ipc547d_firmwaresimatic_ipc847cprime_q270m-c_firmwaresimatic_ipc547dh170m-plus_firmwareb250_mining_expert_firmwarerog_strix_h270i_gamingrog_strix_z270h_gaming\/k1_firmwareprime_z370-pz170-e_firmwarerog_maximus_viii_extreme_firmwareb250_mining_expertb150m-a_d3simatic_ipc677dh110m-c2prime_b250m-a_firmwaresimatic_ipc627c_firmwareprime_b250m-plus\/br_firmwarez170-ah110m-k_firmwaretuf_z270_mark_1_firmwareb150_pro_gaming_d3q170m-c_firmwarez170_pro_gaming\/auraex-b250m-vh110m-a\/m.2_firmwareb150m-d_firmwarerog_strix_b250f_gaming_firmwareprime_z370-a_firmwaresinumerik_pcu50.5-crog_maximus_x_code_firmwarerog_maximus_viii_impactsimatic_ipc827d_firmwareprime_b250m-plus_firmwarez170-deluxeb150m-cprime_b250m-plush110m-cs_xb150-pro_d3_firmwareprime_b250-proz170-a_firmwareb150_pro_gaming_d3_firmwareb150-plusprime_z270-a_firmwareprime_z270-k_firmwareh110m-c\/hdmisimatic_itp1000_firmwareprime_b250-a_firmwareprime_b250-arog_maximus_viii_geneh110t-aex-b250m-v5_firmwaresimatic_ipc647c_firmwareb150-a_firmwaresimatic_ipc427drog_maximus_viii_impact_firmwareq170th110m-r_firmwareh110m-crog_maximus_ix_apex_firmwareprime_z270-ar_firmwarez170_pro_gaming\/aura_firmwareh110m-fprime_b250m-k_firmwareprime_b250m-j_firmwarerog_strix_z370-e_gamingprime_b250m-c_firmwarerog_strix_z270i_gaming_firmwareprime_b250m-ah110m-p\/dvi_firmwareb150m-a_firmwareh170-plus_d3h110m-c\/brrog_strix_b250g_gamingb250-srog_maximus_ix_extreme_firmwareprime_z270m-plusb150_pro_gaming_firmwareex-b150-v7prime_j3355i-c_firmwareb150m-c_d3_firmwaresimatic_ipc427eprime_b250-pro_firmwareh110tq170m2\/cdm\/sib150m-a\/m.2z170_pro_gaming_firmwarerog_strix_z270e_gaming_firmwareb150m-c_firmwarerog_strix_z370-e_gaming_firmwareb150_pro_gaming\/auraq170m2prime_b250m-kprime_z370-aex-h110m-vh110m-dq170t_v2b150m-plus_firmwaresimatic_ipc647csinumerik_pcu50.5-c_firmwareb150m-a\/m.2_firmwareprime_h110m-p_firmwarez170-pro_firmwaresimatic_ipc847dh110m-k_d3z170-premiumex-b250m-v_firmwarerog_strix_z370-g_gaming_firmwareh110i-plussimatic_ipc477d_pro_firmwareb250m-f_plus_firmwarerog_maximus_viii_rangerh110m-plus_firmwareh110m-f_firmwareex-b150m-vtrooper_h110_d3_firmwarerog_maximus_x_apex_firmwarez170i_pro_gamingsimatic_field_pg_m5_firmwaretrooper_b150_d3simatic_ipc677d_firmwarerog_maximus_ix_apexh110m-a\/dpb150m-c\/brrog_strix_z370-i_gaming_firmwareh170-pro_firmwareb150i_pro_gaming\/wifi\/aura_firmwareh110m-erog_maximus_x_heroh110m-cs_firmwareh110m-cssimatic_field_pg_m4_firmwareh110m-cs_x_firmwareb150m-c_d3rog_maximus_viii_extremeh110s1_firmwaretuf_z270_mark_1z170m-plus\/br_firmwareex-b150m-v3prime_z270-pb150-plus_firmwareprime_z370-p_firmwareq170m2\/cdm\/si_firmwarerog_maximus_ix_formulatuf_z370-pro_gamingh170m-e_d3_firmwareb250m-c_prorog_strix_b250i_gamingrog_strix_z370-h_gamingprime_z270m-plus\/brh110m-ks_firmwareb250-mr_firmwareq170m-cm-b_firmwaresimatic_ipc477e_firmwarerog_strix_h270f_gamingrog_strix_z370-f_gaming_firmwareh110s1prime_h270m-plusz170-p_d3prime_b250m-cz170i_pro_gaming_firmwarerog_maximus_viii_heroh110m-tssimatic_ipc477d_propio-b250i_firmwareq170t_v2_firmwareprime_h270m-plus_firmwareb150m-c\/br_firmwareq170m-crog_maximus_x_codetuf_z370-plus_gamingb250-mrh170-prosimatic_ipc547erog_maximus_viii_formula_firmwareb250m-c_pro_firmwarerog_strix_h270f_gaming_firmwareh170-pro\/usb_3.1z170-p_d3_firmwarerog_maximus_x_apexpio-b250ib150m_pro_gaming_firmwarez170m-plus_firmwaresimatic_ipc547e_firmwaresimatic_ipc827dh110m-c\/psh110m-k_d3_firmwarerog_maximus_viii_hero_alphasimatic_field_pg_m5b150i_pro_gaming\/wifi\/aurarog_strix_z270h_gaming_firmwarerog_maximus_ix_code_firmwareprime_h270-pro_firmwareb150m_pro_gamingh110m-c2\/tfq270m-cm-a_firmwareh110m-c2_firmwarerog_strix_z270e_gamingtuf_z270_mark_2_firmwaresimatic_ipc677c_firmwareprime_b250m-plus\/brq270-s_firmwareh110t_firmwareex-b250m-v3_firmwarez170-ph110m-e\/m.2z170-arh110m-k_xsinumerik_pcu50.5-pb250-s_firmwareprime_z270-asimotion_p320-4s_firmwareprime_b250-plusprime_h270-plussimatic_ipc847d_firmwareh170m-plus\/br_firmwarez170_pro_gamingsimatic_ipc827c_firmwareActive Management Technology
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-2689
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.53% / 67.33%
||
7 Day CHG~0.00%
Published-29 Mar, 2017 | 01:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings.

Action-Not Available
Vendor-n/aSiemens AG
Product-ruggedcom_rox_iRUGGEDCOM ROX I All versions
CWE ID-CWE-285
Improper Authorization
CWE ID-CWE-287
Improper Authentication
CVE-2020-25239
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.50%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2025-40815
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.05% / 14.41%
||
7 Day CHG~0.00%
Published-11 Nov, 2025 | 20:20
Updated-12 Nov, 2025 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.

Action-Not Available
Vendor-Siemens AG
Product-LOGO! 24CESIPLUS LOGO! 12/24RCESIPLUS LOGO! 12/24RCEoSIPLUS LOGO! 230RCEoLOGO! 12/24RCEoLOGO! 24RCESIPLUS LOGO! 24RCEoSIPLUS LOGO! 24RCELOGO! 230RCEoSIPLUS LOGO! 24CEoLOGO! 12/24RCELOGO! 24RCEoLOGO! 24CEoLOGO! 230RCESIPLUS LOGO! 230RCESIPLUS LOGO! 24CE
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-40746
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-0.56% / 68.38%
||
7 Day CHG+0.05%
Published-12 Aug, 2025 | 11:17
Updated-20 Aug, 2025 | 20:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with 'NT Authority/SYSTEM' privileges.

Action-Not Available
Vendor-Siemens AG
Product-simatic_rtls_locating_managerSIMATIC RTLS Locating Manager
CWE ID-CWE-20
Improper Input Validation
CVE-2024-41788
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-1.02% / 77.31%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-23 Sep, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-7kt_pac1260_data_manager7kt_pac1260_data_manager_firmwareSENTRON 7KT PAC1260 Data Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-41903
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.35% / 57.33%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-14 Aug, 2024 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root filesystem with read and write privileges. This could allow an attacker to alter the container's filesystem leading to unauthorized modifications and data corruption.

Action-Not Available
Vendor-Siemens AG
Product-sinec_traffic_analyzerSINEC Traffic Analyzersinec_traffic_analyzer
CWE ID-CWE-269
Improper Privilege Management
CVE-2024-41789
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-1.02% / 77.31%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-23 Sep, 2025 | 16:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-7kt_pac1260_data_manager7kt_pac1260_data_manager_firmwareSENTRON 7KT PAC1260 Data Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-41790
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-1.02% / 77.31%
||
7 Day CHG~0.00%
Published-08 Apr, 2025 | 08:22
Updated-23 Sep, 2025 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-7kt_pac1260_data_manager7kt_pac1260_data_manager_firmwareSENTRON 7KT PAC1260 Data Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-38878
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-12.77% / 94.03%
||
7 Day CHG+3.82%
Published-02 Aug, 2024 | 10:36
Updated-03 Nov, 2025 | 22:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.

Action-Not Available
Vendor-Siemens AG
Product-omnivise_t3000_application_serverOmnivise T3000 R8.2 SP4Omnivise T3000 R8.2 SP3Omnivise T3000 Application Server R9.2
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-39569
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-2.45% / 85.22%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:05
Updated-27 Aug, 2025 | 20:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_clientSINEMA Remote Connect Clientsinema_remote_connect_client
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-24635
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-5.40% / 90.15%
||
7 Day CHG+0.95%
Published-29 Mar, 2021 | 19:05
Updated-04 Aug, 2024 | 15:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-25240
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 56.50%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2024-31485
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.63% / 70.41%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-SICORE Base systemCPCI85 Central Processing/Communicationsicore_base_systemcpci85_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-27943
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.61% / 85.66%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload generic files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-27945
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.41% / 85.11%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The bulk import feature of the affected systems allow a privileged user to upload files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2024-27944
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.41% / 85.11%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-73
External Control of File Name or Path
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-49692
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-0.14% / 33.23%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-13 Aug, 2024 | 07:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.

Action-Not Available
Vendor-Siemens AG
Product-6gk5876-4aa10-2ba26gk5876-4aa00-2da2_firmware6gk5812-1ba00-2aa26gk5856-2ea00-3aa16gk6108-4am00-2da26gk5876-4aa00-2da26gk5876-3aa02-2ba2_firmware6gk5816-1aa00-2aa2_firmware6gk5876-3aa02-2ea2_firmware6gk5876-4aa00-2ba26gk5826-2ab00-2ab26gk5856-2ea00-3aa1_firmware6gk5876-4aa00-2ba2_firmware6gk5812-1aa00-2aa26gk6108-4am00-2da2_firmware6gk5856-2ea00-3da1_firmware6gk5874-2aa00-2aa2_firmware6gk5804-0ap00-2aa2_firmware6gk5874-3aa00-2aa26gk5812-1aa00-2aa2_firmware6gk5816-1ba00-2aa26gk5874-2aa00-2aa26gk5826-2ab00-2ab2_firmware6gk6108-4am00-2ba26gk5615-0aa00-2aa26gk5856-2ea00-3da16gk5816-1ba00-2aa2_firmware6gk5874-3aa00-2aa2_firmware6gk5853-2ea00-2da16gk5804-0ap00-2aa26gk5615-0aa01-2aa2_firmware6gk5876-3aa02-2ea26gk5876-4aa10-2ba2_firmware6gk5876-3aa02-2ba26gk6108-4am00-2ba2_firmware6gk5853-2ea00-2da1_firmware6gk5812-1ba00-2aa2_firmware6gk5615-0aa00-2aa2_firmware6gk5816-1aa00-2aa26gk5615-0aa01-2aa2SCALANCE M874-3SCALANCE M816-1 ADSL-RouterSCALANCE M876-3 (ROK)SCALANCE M812-1 ADSL-RouterSCALANCE M804PBSCALANCE MUM856-1 (EU)SCALANCE MUM853-1 (EU)SCALANCE S615 EEC LAN-RouterSCALANCE M874-2SCALANCE M876-4RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M876-3SCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (RoW)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M876-4 (EU)SCALANCE M876-4 (NAM)SCALANCE S615 LAN-Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-49691
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-0.12% / 30.77%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-13 Aug, 2024 | 07:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the handling of the DDNS configuration. This could allow malicious local administrators to issue commands on system level after a successful IP address update.

Action-Not Available
Vendor-Siemens AG
Product-6gk5876-4aa10-2ba26gk5876-4aa00-2da2_firmware6gk5812-1ba00-2aa26gk5856-2ea00-3aa16gk6108-4am00-2da26gk5876-4aa00-2da26gk5876-3aa02-2ba2_firmware6gk5816-1aa00-2aa2_firmware6gk5876-3aa02-2ea2_firmware6gk5876-4aa00-2ba26gk5826-2ab00-2ab26gk5856-2ea00-3aa1_firmware6gk5876-4aa00-2ba2_firmware6gk5812-1aa00-2aa26gk6108-4am00-2da2_firmware6gk5856-2ea00-3da1_firmware6gk5874-2aa00-2aa2_firmware6gk5804-0ap00-2aa2_firmware6gk5874-3aa00-2aa26gk5812-1aa00-2aa2_firmware6gk5816-1ba00-2aa26gk5874-2aa00-2aa26gk5826-2ab00-2ab2_firmware6gk6108-4am00-2ba26gk5615-0aa00-2aa26gk5856-2ea00-3da16gk5816-1ba00-2aa2_firmware6gk5874-3aa00-2aa2_firmware6gk5853-2ea00-2da16gk5804-0ap00-2aa26gk5615-0aa01-2aa2_firmware6gk5876-3aa02-2ea26gk5876-4aa10-2ba2_firmware6gk5876-3aa02-2ba26gk6108-4am00-2ba2_firmware6gk5853-2ea00-2da1_firmware6gk5812-1ba00-2aa2_firmware6gk5615-0aa00-2aa2_firmware6gk5816-1aa00-2aa26gk5615-0aa01-2aa2SCALANCE M874-3SCALANCE M816-1 ADSL-RouterSCALANCE M876-3 (ROK)SCALANCE M812-1 ADSL-RouterSCALANCE M804PBSCALANCE MUM856-1 (EU)SCALANCE MUM853-1 (EU)SCALANCE S615 EEC LAN-RouterSCALANCE M874-2SCALANCE M876-4RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M876-3SCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (RoW)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M876-4 (EU)SCALANCE M876-4 (NAM)SCALANCE S615 LAN-Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-6581
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.30% / 52.99%
||
7 Day CHG~0.00%
Published-12 Jun, 2019 | 13:47
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_video_management_software_2017_r2siveillance_video_management_software_2019_r1siveillance_video_management_software_2018_r2siveillance_video_management_software_2018_r1siveillance_video_management_software_2018_r3Siveillance VMS 2018 R3Siveillance VMS 2018 R1Siveillance VMS 2019 R1Siveillance VMS 2017 R2Siveillance VMS 2018 R2
CWE ID-CWE-285
Improper Authorization
CVE-2023-44317
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.15% / 35.50%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:03
Updated-14 Jan, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xp216_firmwarescalance_xc224-4c_g_firmwarescalance_xr328-4c_wg_\(24xfe\,_4xge\,dc24v\)scalance_xb213-3_\(st\,_pn\)_firmwarescalance_xb213-3_\(sc\,_e\/ip\)_firmwarescalance_xb213-3_\(st\,_e\/ip\)_firmwarescalance_xr326-2c_poe_wgscalance_xb216_\(pn\)scalance_xb213-3ld_\(sc\,_pn\)scalance_xp216eec_firmwarescalance_xb205-3_\(st\,_pn\)scalance_xr324wg_\(24_x_fe\,_ac_230v\)_firmwarescalance_xb205-3_\(sc\,_pn\)_firmwarescalance_xc216-4c_g_\(eip_def.\)scalance_xc206-2sfp_eecscalance_xc224-4c_g_eecscalance_xp208eecscalance_xb213-3ld_\(sc\,_e\/ip\)scalance_xc208g_\(eip_def.\)scalance_xc208g_poe_\(54_v_dc\)_firmwarescalance_xb208_\(e\/ip\)scalance_xc206-2sfp_g_firmwarescalance_xc216eec_firmwarescalance_xb208_\(pn\)_firmwarescalance_xc224_firmwarescalance_xp216_\(ethernet\/ip\)_firmwarescalance_xr326-2c_poe_wg_\(without_ul\)_firmwarescalance_xc206-2sfp_gscalance_xc208eec_firmwarescalance_xp216siplus_net_scalance_xc208scalance_xb205-3_\(st\,_e\/ip\)scalance_xb205-3_\(st\,_pn\)_firmwarescalance_xb205-3ld_\(sc\,_e\/ip\)_firmwarescalance_xr324wg_\(24_x_fe\,_dc_24v\)_firmwarescalance_xr328-4c_wg_\(28xge\,_ac_230v\)scalance_xc208g_poe_firmwarescalance_xf204_dna_firmwarescalance_xr328-4c_wg_\(28xge\,_dc_24v\)scalance_xp216poe_eec_firmwarescalance_xc206-2sfp_g_\(eip_def.\)scalance_xc216-4c_gscalance_xc206-2g_poe_\(54_v_dc\)_firmwarescalance_xc206-2g_poescalance_xc216-4c_firmwarescalance_xc216-4c_g_firmwarescalance_xp208poe_eecscalance_xc208g_poe_\(54_v_dc\)scalance_xb213-3_\(sc\,_pn\)siplus_net_scalance_xc206-2sfpscalance_xb205-3_\(st\,_e\/ip\)_firmwarescalance_xb216_\(e\/ip\)scalance_xc216-3g_poe_firmwarescalance_xr328-4c_wg_\(28xge\,_dc_24v\)_firmwarescalance_xc208g_\(eip_def.\)_firmwarescalance_xf204-2ba_dna_firmwarescalance_xc224-4c_g_eec_firmwarescalance_xb205-3ld_\(sc\,_e\/ip\)scalance_xb213-3_\(sc\,_e\/ip\)scalance_xb213-3_\(sc\,_pn\)_firmwarescalance_xb213-3_\(st\,_e\/ip\)scalance_xf204siplus_net_scalance_xc206-2_firmwarescalance_xc206-2sfp_g_eecscalance_xc206-2sfp_g_\(eip_def.\)_firmwarescalance_xc208eecscalance_xc206-2_\(sc\)_firmwarescalance_xr328-4c_wg_\(24xfe\,4xge\,ac230v\)siplus_net_scalance_xc216-4cscalance_xc208_firmwarescalance_xb213-3ld_\(sc\,_pn\)_firmwarescalance_xr328-4c_wg_\(24xfe\,_4xge\,_24v\)scalance_xc224scalance_xc224-4c_gscalance_xb216_\(e\/ip\)_firmwarescalance_xc216-4c_g_eecscalance_xr328-4c_wg_\(24xfe\,4xge\,ac230v\)_firmwarescalance_xc206-2sfp_g_eec_firmwaresiplus_net_scalance_xc206-2scalance_xc216-3g_poe_\(54_v_dc\)scalance_xp216poe_eecscalance_xc206-2g_poe_eec_\(54_v_dc\)scalance_xc206-2sfp_firmwarescalance_xc206-2_\(st\/bfoc\)scalance_xr328-4c_wg_\(24xfe\,_4xge\,_24v\)_firmwarescalance_xp208poe_eec_firmwarescalance_xb205-3ld_\(sc\,_pn\)scalance_xr328-4c_wg_\(28xge\,_ac_230v\)_firmwarescalance_xr326-2c_poe_wg_firmwaresiplus_net_scalance_xc206-2sfp_firmwarescalance_xc216-4csiplus_net_scalance_xc208_firmwarescalance_xf204-2ba_firmwarescalance_xr324wg_\(24_x_fe\,_ac_230v\)scalance_xb205-3ld_\(sc\,_pn\)_firmwarescalance_xc208g_eec_firmwarescalance_xc206-2sfpscalance_xc206-2g_poe_firmwarescalance_xb208_\(pn\)scalance_xr326-2c_poe_wg_\(without_ul\)scalance_xc208g_poescalance_xp216_\(ethernet\/ip\)siplus_net_scalance_xc216-4c_firmwarescalance_xc224-4c_g_\(eip_def.\)scalance_xc206-2_\(sc\)scalance_xr324wg_\(24_x_fe\,_dc_24v\)scalance_xp208_firmwarescalance_xc216-4c_g_eec_firmwarescalance_xc216scalance_xb205-3_\(sc\,_pn\)scalance_xp208scalance_xf204-2bascalance_xc206-2_\(st\/bfoc\)_firmwarescalance_xb213-3_\(st\,_pn\)scalance_xc206-2sfp_eec_firmwarescalance_xb208_\(e\/ip\)_firmwarescalance_xc224-4c_g_\(eip_def.\)_firmwarescalance_xp208eec_firmwarescalance_xp216eecscalance_xc208g_eecscalance_xf204_dnascalance_xr328-4c_wg_\(24xfe\,_4xge\,dc24v\)_firmwarescalance_xc206-2g_poe_\(54_v_dc\)scalance_xc216-4c_g_\(eip_def.\)_firmwarescalance_xb216_\(pn\)_firmwarescalance_xc216_firmwarescalance_xc208gscalance_xc216-3g_poe_\(54_v_dc\)_firmwarescalance_xf204-2ba_dnascalance_xb213-3ld_\(sc\,_e\/ip\)_firmwarescalance_xc208g_firmwarescalance_xc206-2g_poe_eec_\(54_v_dc\)_firmwarescalance_xp208_\(ethernet\/ip\)scalance_xf204_firmwarescalance_xc216-3g_poescalance_xc216eecscalance_xp208_\(ethernet\/ip\)_firmwarescalance_xc208SCALANCE S615 LAN-RouterSCALANCE WAM766-1 (ME)SCALANCE WAM766-1SCALANCE M876-3SCALANCE WUB762-1 iFeaturesSCALANCE WUM766-1SCALANCE M812-1 ADSL-RouterSCALANCE WUM766-1 (ME)SCALANCE M816-1 ADSL-RouterSCALANCE M876-4 (EU)SCALANCE WUB762-1RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M874-2SCALANCE WAM763-1SCALANCE M804PBSCALANCE WAM766-1 EEC (ME)SCALANCE WAM766-1 EECSCALANCE WUM763-1 (US)SCALANCE WAM766-1 EEC (US)SCALANCE WUM763-1SCALANCE WUM766-1 (USA)SCALANCE WAM763-1 (US)SCALANCE MUM853-1 (EU)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (RoW)SCALANCE M876-4SCALANCE WAB762-1SCALANCE M876-3 (ROK)SCALANCE WAM763-1 (ME)SCALANCE MUM856-1 (EU)SCALANCE WAM766-1 (US)SCALANCE M874-3SCALANCE S615 EEC LAN-RouterSCALANCE M876-4 (NAM)
CWE ID-CWE-349
Acceptance of Extraneous Untrusted Data With Trusted Data
CVE-2023-42797
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-6.6||MEDIUM
EPSS-0.22% / 45.23%
||
7 Day CHG-0.07%
Published-09 Jan, 2024 | 09:59
Updated-03 Jun, 2025 | 14:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.

Action-Not Available
Vendor-Siemens AG
Product-sicam_a8000_cp-8031sicam_a8000_cp-8050sicam_a8000_cp-8031_firmwaresicam_a8000_cp-8050_firmwareCP-8050 MASTER MODULECP-8031 MASTER MODULE
CWE ID-CWE-908
Use of Uninitialized Resource
CVE-2025-27395
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.19% / 40.69%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-22 Aug, 2025 | 18:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the scope of files accessible through and the privileges of the SFTP functionality. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-36754
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-1.01% / 77.14%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-10 Dec, 2024 | 17:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-36751
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-1.21% / 78.99%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-26 Nov, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512ruggedcom_rox_mx5000reruggedcom_rox_rx1524ruggedcom_rox_rx1400ruggedcom_rox_rx1501ruggedcom_rox_rx1500ruggedcom_rox_rx1511ruggedcom_rox_rx5000ruggedcom_rox_rx1512ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1510
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-33919
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-9.85% / 93.00%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Nov, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-cp-8031_master_modulecp-8050_master_modulecpci85_firmwareCP-8050 MASTER MODULECP-8031 MASTER MODULEcp-8031_master_modulecp-8050_master_module
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-28832
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-1.08% / 77.84%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-6gk1411-1ac00_firmware6gk1411-5ac00_firmware6gk1411-1ac006gk1411-5ac00SIMATIC Cloud Connect 7 CC716SIMATIC Cloud Connect 7 CC712
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7082
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-2.40% / 85.09%
||
7 Day CHG+0.47%
Published-10 May, 2019 | 16:49
Updated-05 Aug, 2024 | 06:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that would not be logged. Workaround: None. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dAruba Instant (IAP)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-36753
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-1.73% / 82.46%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-02 Dec, 2024 | 18:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512ruggedcom_rox_mx5000reruggedcom_rox_rx1524ruggedcom_rox_rx1400ruggedcom_rox_rx1501ruggedcom_rox_rx1500ruggedcom_rox_rx1511ruggedcom_rox_rx5000ruggedcom_rox_rx1512ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1510
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-36755
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-1.10% / 78.07%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-19 Nov, 2024 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1400ruggedcom_rox_rx1500ruggedcom_rox_rx5000ruggedcom_rox_rx1512ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41547
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-0.82% / 74.47%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.11), Teamcenter Active Workspace V5.0 (All versions < V5.0.10), Teamcenter Active Workspace V5.1 (All versions < V5.1.6), Teamcenter Active Workspace V5.2 (All versions < V5.2.3). The application contains an unsafe unzipping pattern that could lead to a zip path traversal attack. This could allow and attacker to execute a remote shell with admin rights.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V4.3Teamcenter Active Workspace V5.0Teamcenter Active Workspace V5.2Teamcenter Active Workspace V5.1
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-37721
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-4.74% / 89.43%
||
7 Day CHG+1.19%
Published-07 Sep, 2021 | 12:35
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba SD-WAN Software and Gateways; Aruba Operating System Software version(s): Prior to 8.6.0.4-2.2.0.4; Prior to 8.7.1.4, 8.6.0.9, 8.5.0.13, 8.3.0.16, 6.5.4.20, 6.4.4.25. Aruba has released patches for Aruba SD-WAN Software and Gateways and ArubaOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaossd-wanscalance_w1750d_firmwarescalance_w1750dAruba SD-WAN Software and Gateways; Aruba Operating System Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-25753
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-3.35% / 87.35%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecscalance_x308-2lh\+SCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-44165
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-2.26% / 84.62%
||
7 Day CHG~0.00%
Published-14 Dec, 2021 | 12:06
Updated-04 Aug, 2024 | 04:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.

Action-Not Available
Vendor-Siemens AG
Product-7kg9501-0aa01-2aa17kg9501-0aa01-2aa1_firmware7kg9501-0aa31-0aa1_firmware7kg9501-0aa01-0aa17kg9501-0aa31-0aa17kg9501-0aa31-2aa17kg9501-0aa01-0aa1_firmware7kg9501-0aa31-2aa1_firmwarePOWER METER SICAM Q100
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-37727
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-8
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.40% / 87.44%
||
7 Day CHG+0.70%
Published-12 Oct, 2021 | 14:08
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in HPE Aruba Instant (IAP) version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.20 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-33728
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-1.99% / 83.66%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to upload JSON objects that are deserialized to JAVA objects. Due to insecure deserialization of user-supplied content by the affected software, a privileged attacker could exploit this vulnerability by sending a crafted serialized Java object. An exploit could allow the attacker to execute arbitrary code on the device with root privileges.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2025-30032
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.94% / 76.32%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30003
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.94% / 76.32%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30030
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.94% / 76.32%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30002
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.94% / 76.32%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-27539
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.72% / 72.54%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-10916
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.83%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7simatic_wincc_runtime_professionalsimatic_wincc_\(tia_portal\)SIMATIC WinCC Runtime Professional V13SIMATIC WinCC (TIA Portal) V14SIMATIC WinCC (TIA Portal) V13SIMATIC WinCC Runtime Professional V14SIMATIC PCS 7 V8.2SIMATIC WinCC V7.3SIMATIC PCS 7 V9.0SIMATIC WinCC (TIA Portal) V15SIMATIC PCS 7 V8.1SIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC PCS 7 V8.0 and earlierSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2016-8564
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.23% / 45.88%
||
7 Day CHG~0.00%
Published-13 Oct, 2016 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

SQL injection vulnerability in Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to execute arbitrary SQL commands via crafted traffic to TCP port 4410.

Action-Not Available
Vendor-n/aSiemens AG
Product-automation_license_managern/a
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-26390
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.34% / 56.74%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 09:38
Updated-03 Oct, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

Action-Not Available
Vendor-Siemens AG
Product-ozw772ozw672ozw672_firmwareozw772_firmwareOZW772OZW672
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2020-7577
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.80% / 74.06%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Camstar Enterprise Platform (All versions), Opcenter Execution Core (All versions < V8.2). Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to the back-end server. The exploit of this vulnerability could be used to read, and potentially modify application data to which the user has access to.

Action-Not Available
Vendor-Siemens AG
Product-opcenter_execution_coreCamstar Enterprise PlatformOpcenter Execution Core
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-52335
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.86% / 75.13%
||
7 Day CHG~0.00%
Published-06 Dec, 2024 | 13:14
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-syngo.plaza VB30Esyngo_plaza_vb30e
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 87
  • 88
  • Next
Details not found