Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-37180

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-10 Aug, 2021 | 10:35
Updated At-04 Aug, 2024 | 01:16
Rejected At-
Credits

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:10 Aug, 2021 | 10:35
Updated At:04 Aug, 2024 | 01:16
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

Affected Products
Vendor
Siemens AGSiemens
Product
Solid Edge SE2021
Versions
Affected
  • All Versions < SE2021MP7
Problem Types
TypeCWE IDDescription
CWECWE-824CWE-824: Access of Uninitialized Pointer
Type: CWE
CWE ID: CWE-824
Description: CWE-824: Access of Uninitialized Pointer
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf
x_refsource_MISC
https://www.zerodayinitiative.com/advisories/ZDI-21-1113/
x_refsource_MISC
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf
Resource:
x_refsource_MISC
Hyperlink: https://www.zerodayinitiative.com/advisories/ZDI-21-1113/
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf
x_refsource_MISC
x_transferred
https://www.zerodayinitiative.com/advisories/ZDI-21-1113/
x_refsource_MISC
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://www.zerodayinitiative.com/advisories/ZDI-21-1113/
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:10 Aug, 2021 | 11:15
Updated At:16 Dec, 2021 | 18:20

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>solid_edge_se2021_firmware>>Versions before se2021mp7(exclusive)
cpe:2.3:o:siemens:solid_edge_se2021_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>solid_edge_se2021>>-
cpe:2.3:h:siemens:solid_edge_se2021:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-824Primaryproductcert@siemens.com
CWE-824Secondarynvd@nist.gov
CWE ID: CWE-824
Type: Primary
Source: productcert@siemens.com
CWE ID: CWE-824
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdfproductcert@siemens.com
Patch
Vendor Advisory
https://www.zerodayinitiative.com/advisories/ZDI-21-1113/productcert@siemens.com
Third Party Advisory
VDB Entry
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf
Source: productcert@siemens.com
Resource:
Patch
Vendor Advisory
Hyperlink: https://www.zerodayinitiative.com/advisories/ZDI-21-1113/
Source: productcert@siemens.com
Resource:
Third Party Advisory
VDB Entry

Change History

0
Information is not available yet

Similar CVEs

582Records found

CVE-2022-47936
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 31.14%
||
7 Day CHG~0.00%
Published-14 Feb, 2023 | 10:36
Updated-20 Mar, 2025 | 20:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt_utilitiesjt_open_toolkitparasolidParasolid V34.0JT UtilitiesJT OpenParasolid V34.1Parasolid V35.1Parasolid V35.0
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-40438
Matching Score-8
Assigner-Apache Software Foundation
ShareView Details
Matching Score-8
Assigner-Apache Software Foundation
CVSS Score-9||CRITICAL
EPSS-94.44% / 99.99%
||
7 Day CHG~0.00%
Published-16 Sep, 2021 | 14:40
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2021-12-15||Apply updates per vendor instructions.
mod_proxy SSRF

A crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier.

Action-Not Available
Vendor-resfF5, Inc.The Apache Software FoundationOracle CorporationFedora ProjectSiemens AGBroadcom Inc.Tenable, Inc.NetApp, Inc.Red Hat, Inc.Debian GNU/Linux
Product-enterprise_linux_for_power_big_endianenterprise_linux_server_workstationenterprise_linux_workstationsinec_nmsenterprise_linux_server_ausbrocade_fabric_operating_system_firmwaresoftware_collectionsenterprise_linux_update_services_for_sap_solutionsclustered_data_ontapenterprise_linux_serverzfs_storage_appliance_kitsecure_global_desktopenterprise_linux_for_power_little_endiansinema_serverenterprise_linux_for_arm_64storagegridf5osenterprise_linux_server_for_power_little_endian_update_services_for_sap_solutionsenterprise_linux_eusenterprise_linux_server_tusenterprise_linux_server_update_services_for_sap_solutionsenterprise_linuxhttp_serverinstantis_enterprisetrackcloud_backuptenable.scrocky_linuxenterprise_manager_ops_centerruggedcom_nmsenterprise_linux_for_scientific_computingenterprise_linux_for_ibm_z_systemsenterprise_linux_for_power_little_endian_eussinema_remote_connect_serverfedorajboss_core_servicesdebian_linuxenterprise_linux_for_ibm_z_systems_eus_s390xenterprise_linux_for_ibm_z_systems_eusenterprise_linux_for_arm_64_eusApache HTTP ServerApache
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2023-49122
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.15% / 36.15%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-27 Aug, 2025 | 20:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-29878
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-0.44% / 62.29%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a valid challenge-response pair generated by a legitimate user, and request the webpage repeatedly to wait for the same challenge to reappear for which the correct response is known. This could allow the attacker to access the management interface of the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg8501-0aa11-2aa0_firmware7kg8551-0aa01-2aa07kg8501-0aa11-0aa07kg8500-0aa10-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8551-0aa02-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-0aa07kg8550-0aa00-0aa0_firmware7kg8501-0aa01-0aa07kg8551-0aa02-0aa07kg8500-0aa30-0aa07kg8551-0aa32-0aa0_firmware7kg8551-0aa02-2aa07kg8550-0aa30-0aa0_firmware7kg8501-0aa32-0aa07kg8500-0aa30-2aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa12-2aa07kg8500-0aa00-0aa07kg8551-0aa01-0aa0_firmware7kg8501-0aa11-2aa07kg8501-0aa31-0aa07kg8501-0aa12-2aa0_firmware7kg8501-0aa32-2aa07kg8550-0aa00-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa31-0aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa12-0aa0_firmware7kg8551-0aa12-0aa07kg8500-0aa30-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8500-0aa00-2aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8501-0aa02-0aa0_firmware7kg8500-0aa10-0aa07kg8551-0aa12-0aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa32-2aa07kg8501-0aa11-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa02-2aa0_firmware7kg8551-0aa32-0aa07kg8501-0aa32-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8501-0aa01-2aa07kg8550-0aa00-2aa07kg8551-0aa31-2aa0_firmware7kg8551-0aa11-2aa07kg8501-0aa12-0aa07kg8551-0aa31-0aa0_firmware7kg8551-0aa11-0aa07kg8500-0aa00-2aa07kg8551-0aa01-2aa0_firmware7kg8550-0aa10-2aa0_firmware7kg8550-0aa10-0aa07kg8551-0aa31-0aa07kg8551-0aa11-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8551-0aa01-0aa07kg8501-0aa02-2aa07kg8500-0aa10-2aa07kg8551-0aa31-2aa07kg8501-0aa31-2aa07kg8501-0aa12-2aa07kg8500-0aa00-0aa0_firmwareSICAM P850SICAM P855
CWE ID-CWE-294
Authentication Bypass by Capture-replay
CVE-2023-49124
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.17%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-27 Aug, 2025 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-32946
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.30% / 52.91%
||
7 Day CHG~0.00%
Published-17 Jun, 2021 | 11:56
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_sdkteamcenter_visualizationDrawings SDK
CWE ID-CWE-754
Improper Check for Unusual or Exceptional Conditions
CVE-2015-1597
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.40% / 60.05%
||
7 Day CHG~0.00%
Published-07 Mar, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.

Action-Not Available
Vendor-n/aSiemens AG
Product-spcanywheren/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2023-49129
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.15% / 36.15%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 10:00
Updated-17 Jun, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain a stack overflow vulnerability while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-31784
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.32% / 54.49%
||
7 Day CHG~0.00%
Published-26 Apr, 2021 | 18:03
Updated-03 Aug, 2024 | 23:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6 on all supported by ODA platforms in static configuration. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution.

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-comosdrawings_sdkn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49127
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.17%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-27 Aug, 2025 | 20:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-31342
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.58% / 67.85%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-n/aSiemens AG
Product-solid_edge_se2020_firmwaresolid_edge_se2021_firmwaresolid_edge_se2020solid_edge_se2021Siemens Solid Edge
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-49126
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.17%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-27 Aug, 2025 | 20:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-125
Out-of-bounds Read
CVE-2015-1049
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.54% / 66.52%
||
7 Day CHG~0.00%
Published-02 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors.

Action-Not Available
Vendor-n/aSiemens AG
Product-scalance_x204irtscalance_x202-2p_irtscalance_x202-2irtscalance_x202-4p_irtscalance_xf204irtscalance_x202-2p_irt_proscalance_x-200_series_firmwarescalance_x204irt_proscalance_x201-3pirtscalance_x201-3p_irt_pron/a
CWE ID-CWE-20
Improper Input Validation
CVE-2023-49123
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.15% / 36.15%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 09:59
Updated-27 Aug, 2025 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2023Solid Edge SE2023
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-37374
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.08% / 25.23%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-08 Nov, 2024 | 16:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-37179
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.53% / 66.36%
||
7 Day CHG~0.00%
Published-10 Aug, 2021 | 10:35
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2021_firmwareSolid Edge SE2021
CWE ID-CWE-416
Use After Free
CVE-2020-12762
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.66%
||
7 Day CHG-0.01%
Published-09 May, 2020 | 00:00
Updated-30 May, 2025 | 20:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_memappend.

Action-Not Available
Vendor-json-cn/aDebian GNU/LinuxFedora ProjectSiemens AGCanonical Ltd.
Product-fedoradebian_linuxubuntu_linuxsinec_insjson-cn/a
CWE ID-CWE-190
Integer Overflow or Wraparound
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34296
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13057)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation
CVE-2021-27397
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.67%
||
7 Day CHG~0.00%
Published-12 May, 2021 | 13:18
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTecnomatix Plant Simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27494
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.62% / 69.04%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 15:26
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-luxiondatakitn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2021-34328
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.45% / 62.66%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13424)

Action-Not Available
Vendor-Siemens AG
Product-jt2gosolid_edgeteamcenter_visualizationJT2GoSolid Edge SE2021Teamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34330
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13430)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-416
Use After Free
CWE ID-CWE-20
Improper Input Validation
CVE-2021-34313
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-34309
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13350)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-20
Improper Input Validation
CVE-2021-27490
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.30% / 52.62%
||
7 Day CHG~0.00%
Published-27 May, 2021 | 16:08
Updated-03 Aug, 2024 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxiondatakitn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020crosscadwareDatakit Software libraries embedded in Luxion KeyShot software
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27380
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.36% / 57.24%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-27381
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge SE2021Solid Edge SE2020
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-27399
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 20:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap 2020.2Simcenter Femap 2021.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25678
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.38% / 58.67%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2021solid_edge_se2020Solid Edge SE2021Solid Edge SE2020
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25670
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.37% / 57.90%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-03 Aug, 2024 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_robotexpertTecnomatix RobotExpert
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25174
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.40% / 59.60%
||
7 Day CHG~0.00%
Published-18 Jan, 2021 | 07:14
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart).

Action-Not Available
Vendor-opendesignn/aSiemens AG
Product-jt2gocomosdrawings_software_development_kitteamcenter_visualizationn/a
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-25216
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
ShareView Details
Matching Score-8
Assigner-Internet Systems Consortium (ISC)
CVSS Score-8.1||HIGH
EPSS-24.73% / 95.93%
||
7 Day CHG~0.00%
Published-29 Apr, 2021 | 00:55
Updated-16 Sep, 2024 | 22:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
A second vulnerability in BIND's GSSAPI security policy negotiation can be targeted by a buffer overflow attack

In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security.

Action-Not Available
Vendor-NetApp, Inc.Debian GNU/LinuxSiemens AGInternet Systems Consortium, Inc.
Product-aff_500f_firmwareh300eh500scloud_backuph300s_firmwareactive_iq_unified_managerh410sh300ssinec_infrastructure_network_servicesh300e_firmwaredebian_linuxh500eh410s_firmwareh700s_firmwareh500s_firmwareh500e_firmwareaff_a250aff_500fh700ebindh700e_firmwareh700saff_a250_firmwareBIND9
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-46345
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.82%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-03 Aug, 2024 | 14:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2022parasolidsolid_edge_se2023Parasolid V34.0Solid Edge SE2023Parasolid V35.0Parasolid V33.1Parasolid V34.1Solid Edge SE2022parasolidsolid_edge
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-22901
Matching Score-8
Assigner-HackerOne
ShareView Details
Matching Score-8
Assigner-HackerOne
CVSS Score-8.1||HIGH
EPSS-0.37% / 57.98%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:49
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.75.0 through 7.76.1 suffers from a use-after-free vulnerability resulting in already freed memory being used when a TLS 1.3 session ticket arrives over a connection. A malicious server can use this in rare unfortunate circumstances to potentially reach remote code execution in the client. When libcurl at run-time sets up support for TLS 1.3 session tickets on a connection using OpenSSL, it stores pointers to the transfer in-memory object for later retrieval when a session ticket arrives. If the connection is used by multiple transfers (like with a reused HTTP/1.1 connection or multiplexed HTTP/2 connection) that first transfer object might be freed before the new session is established on that connection and then the function will access a memory buffer that might be freed. When using that memory, libcurl might even call a function pointer in the object, making it possible for a remote code execution if the server could somehow manage to get crafted memory content into the correct place in memory.

Action-Not Available
Vendor-n/aNetApp, Inc.Oracle CorporationSplunk LLC (Cisco Systems, Inc.)CURLSiemens AG
Product-communications_cloud_native_core_network_function_cloud_native_environmentcloud_backupsolidfire_\&_hci_management_nodeh300s_firmwareh410scurlhci_compute_nodeh300ssnapcenterh300e_firmwaresinec_infrastructure_network_servicesessbaseh500eh500s_firmwareh500e_firmwarecommunications_cloud_native_core_binding_support_functionh700ehci_compute_node_firmwareoncommand_insightcommunications_cloud_native_core_service_communication_proxyh300ecommunications_cloud_native_core_network_slice_selection_functionh500scommunications_cloud_native_core_network_repository_functionactive_iq_unified_manageroncommand_workflow_automationuniversal_forwarderh410s_firmwareh700s_firmwaresolidfire\,_enterprise_sds_\&_hci_storage_nodeh700e_firmwaresolidfire_baseboard_management_controller_firmwareh700smysql_serverhttps://github.com/curl/curl
CWE ID-CWE-416
Use After Free
CVE-2014-4686
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.23% / 45.84%
||
7 Day CHG~0.00%
Published-24 Jul, 2014 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_pcs7winccn/a
CVE-2021-22645
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.25% / 48.33%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:02
Updated-03 Aug, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to an attack because the .bip documents display a “load” command, which can be pointed to a .dll from a remote network share. As a result, the .dll entry point can be executed without sufficient UI warning.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-357
Insufficient UI Warning of Dangerous Operations
CVE-2023-45204
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.17% / 38.14%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-18 Sep, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21268)

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2201Tecnomatix Plant Simulation V2302
CWE ID-CWE-704
Incorrect Type Conversion or Cast
CVE-2023-44086
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.29%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
CVE-2021-22663
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.41% / 60.28%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 16:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cscape (All versions prior to 9.90 SP3.5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-hornerautomationn/aSiemens AG
Product-cscapeCscape
CWE ID-CWE-125
Out-of-bounds Read
CVE-2019-10939
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.8||CRITICAL
EPSS-0.44% / 62.49%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 19:50
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.3). The affected versions contain an open debug port that is available under certain specific conditions. The vulnerability is only available if the IP address is configured to 192.168.1.2. If available, the debug port could be exploited by an attacker with network access to the device. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.

Action-Not Available
Vendor-Siemens AG
Product-tim_4r-ie_dnp3tim_4r-ietim_4r-ie_firmwaretim_3v-ie_dnp3_firmwaretim_3v-ie_advancedtim_3v-ie_advanced_firmwaretim_3v-ie_firmwaretim_3v-ietim_3v-ie_dnp3tim_4r-ie_dnp3_firmwareTIM 3V-IE DNP3 (incl. SIPLUS NET variants)TIM 4R-IE (incl. SIPLUS NET variants)TIM 4R-IE DNP3 (incl. SIPLUS NET variants)TIM 3V-IE (incl. SIPLUS NET variants)TIM 3V-IE Advanced (incl. SIPLUS NET variants)
CWE ID-CWE-489
Active Debug Code
CVE-2021-22649
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.72%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 03:02
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyShotLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot Viewer
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22651
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-1.71% / 81.59%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 17:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

When loading a specially crafted file, Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are, while processing the extraction of temporary files, suffering from a directory traversal vulnerability, which allows an attacker to store arbitrary scripts into automatic startup folders.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot ViewerLuxion KeyShot versions
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2023-45601
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.15% / 36.15%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-19 Sep, 2024 | 14:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)

Action-Not Available
Vendor-Siemens AG
Product-parasolidtecnomatixTecnomatix Plant Simulation V2201Parasolid V35.1Parasolid V35.0Parasolid V36.0Tecnomatix Plant Simulation V2302
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-27653
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 60.98%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 05:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15594)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-45147
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.05% / 16.65%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:04
Updated-27 Aug, 2025 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC STEP 7 V17SIMATIC STEP 7 V18SIMATIC STEP 7 V16SIMATIC PCS neo V4.0simatic_pcs_neosimatic_step_7
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2023-44081
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 40.31%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-44087
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.29%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-44085
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.29%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
CVE-2023-44083
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.18% / 40.31%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-787
Out-of-bounds Write
CVE-2023-44084
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.29%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatixTecnomatix Plant Simulation V2302Tecnomatix Plant Simulation V2201
CWE ID-CWE-125
Out-of-bounds Read
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • ...
  • 11
  • 12
  • Next
Details not found