Improper physical access control and use of hard-coded credentials in /etc/passwd permits an attacker with physical access to obtain a root shell via an unprotected UART port on the device. The same port exposes an unauthenticated Das U-Boot BIOS shell.
Phicomm K2G v22.6.3.20 was discovered to contain a command injection vulnerability via the autoUpTime parameter in the automatic upgrade function.
Phicomm K2 v22.6.534.263 was discovered to contain a command injection vulnerability via the autoUpTime parameter in the automatic upgrade function.
IBM Storage Defender - Resiliency Service 2.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 278749.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary code and commands on the device due to insufficient UART protections.
Brocade SANnav versions before v2.0 use a hard-coded password, which could allow local authenticated attackers to access a back-end database and gain privileges.
NMIS/BioDose software V22.02 and previous versions contain executable binaries with plain text hard-coded passwords. These hard-coded passwords could allow unauthorized access to both the application and database.
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege escalation when logged in as a non-administrative user.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. Hard-coded API Keys exist.
The Zyxel Multy X (AC3000 Tri-Band WiFi System) device doesn't use a suitable mechanism to protect the UART. After an attacker dismantles the device and uses a USB-to-UART cable to connect the device, he can use the 1234 password for the root account to login to the system. Furthermore, an attacker can start the device's TELNET service as a backdoor.
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.
An issue was discovered on TK-Star Q90 Junior GPS horloge 3.1042.9.8656 devices. When using the device at initial setup, a default password is used (123456) for administrative purposes. There is no prompt to change this password. Note that this password can be used in combination with CVE-2019-20470.
Dell ECS versions 3.8.1.0 through 3.8.1.7 and Dell ObjectScale versions prior to 4.3.0.0, contains a use of hard-coded credentials vulnerability. An unauthenticated attacker with local access could potentially exploit this vulnerability, leading to filesystem access for attacker.
A vulnerability in the Cisco FindIT Network Management Software virtual machine (VM) images could allow an unauthenticated, local attacker who has access to the VM console to log in to the device with a static account that has root privileges. The vulnerability is due to the presence of an account with static credentials in the underlying Linux operating system. An attacker could exploit this vulnerability by logging in to the command line of the affected VM with the static account. A successful exploit could allow the attacker to log in with root-level privileges. This vulnerability affects only Cisco FindIT Network Manager and Cisco FindIT Network Probe Release 1.1.4 if these products are using Cisco-supplied VM images. No other releases or deployment models are known to be vulnerable.
This vulnerability enables ssh access to minikube container using a default password.
Precor touchscreen console P62, P80, and P82 could allow a remote attacker (within the local network) to bypass security restrictions, and access the service menu, because there is a hard-coded service code.
The /root/anaconda-ks.cfg installation configuration file in International Datacasting Corporation (IDC) SFX Series(SFX2100) SuperFlex Satellite Receiver insecurely stores the hardcoded root password hash. The password itself is highly insecure and susceptible to offline dictionary attacks using the rockyou.txt wordlist. Because direct root SSH login is disabled, an attacker must first obtain low-privileged access to the system (e.g., via other vulnerabilities) to be able to log in as the root user. The password is hardcoded and so allows for an actor with local access on effected versions to escalate to root
ISOS firmwares from versions 1.81 to 2.00 contain hardcoded credentials from embedded StreamX installer that integrators are not forced to change.
An exposed Telnet Service on the Billion Smart Energy Router SG600R2 with firmware v3.02.rc6 allows a local network attacker to authenticate via hardcoded credentials into a shell, gaining root execution privileges over the device.
Calero VeraSMART versions prior to 2026 R1 contain hardcoded static AES encryption keys within Veramark.Framework.dll (Veramark.Core.Config class). These keys are used to encrypt the password of the service account stored in C:\\VeraSMART Data\\app.settings. An attacker with local access to the system can extract the hardcoded keys from the Veramark.Framework.dll module and decrypt the stored credentials. The recovered credentials can then be used to authenticate to the Windows host, potentially resulting in local privilege escalation depending on the privileges of the configured service account.
The SSH service is enabled on the Zingbox Inspector versions 1.294 and earlier, exposing SSH to the local network. When combined with PAN-SA-2019-0027, this can allow an attacker to authenticate to the service using hardcoded credentials.
In the Zingbox Inspector, versions 1.294 and earlier, hardcoded credentials for root and inspector user accounts are present in the system software, which can result in unauthorized users gaining access to the system.
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
In PCTechSoft PCSecure V5.0.8.xw, use of Hard-coded Credentials in configuration files leads to admin panel access.
Ingenico Telium 2 POS terminals have hardcoded FTP credentials. This is fixed in Telium 2 SDK v9.32.03 patch N.
BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information (ePHI), protected health information (PHI) and personally identifiable information (PII). Customers using BD Totalys MultiProcessor version 1.70 with Microsoft Windows 10 have additional operating system hardening configurations which increase the attack complexity required to exploit this vulnerability.
TOTOLINK A3000RU V4.1.2cu.5185_B20201128 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Patterson Dental Eaglesoft 21 has AES-256 encryption but there are two ways to obtain a keyfile: (1) keybackup.data > License > Encryption Key or (2) Eaglesoft.Server.Configuration.data > DbEncryptKeyPrimary > Encryption Key. Applicable files are encrypted with keys and salt that are hardcoded into a DLL or EXE file.
TOTOLINK A950RG V4.1.2cu.5204_B20210112 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
TOTOLINK N600R V4.3.0cu.7647_B20210106 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Zoom Rooms for macOS clients before version 5.11.4 contain an insecure key generation mechanism. The encryption key used for IPC between the Zoom Rooms daemon service and the Zoom Rooms client was generated using parameters that could be obtained by a local low-privileged application. That key can then be used to interact with the daemon service to execute privileged functions and cause a local denial of service.
TOTOLINK A720R V4.1.5cu.532_B20210610 was discovered to contain a hardcoded password for root at /etc/shadow.sample.
Ingenico Telium 2 POS terminals have hardcoded PPP credentials. This is fixed in Telium 2 SDK v9.32.03 patch N.
A security flaw has been discovered in Tenda AC20 16.03.08.12. Affected by this vulnerability is an unknown functionality of the file /etc_ro/shadow. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, has been found in D-Link DIR-890L up to 111b04. This issue affects some unknown processing of the file rgbin of the component UART Port. The manipulation leads to hard-coded credentials. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC3600 1.0.22. Affected by this issue is some unknown functionality of the file /etc/shadow. The manipulation with the input root:blinkadmin leads to hard-coded credentials. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A use of hard-coded credentials vulnerability [CWE-798] in FortiTester 2.3.0 through 7.2.3 may allow an attacker who managed to get a shell on the device to access the database via shell commands.
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.
The root password of the Loxone Miniserver Go Gen.2 before 14.2 is calculated using hard-coded secrets and the MAC address. This allows a local user to calculate the root password and escalate privileges.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a Hard-coded Password Vulnerability. An attacker, with the knowledge of the hard-coded credentials, could potentially exploit this vulnerability to login to the system to gain admin privileges.
Penta Security Systems Inc WAPPLES v6.0 r3 4.10-hotfix1 allows attackers to escalate privileges via overwriting files using SUID flagged executables.
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
A improper authentication vulnerability in Fortinet FortiSIEM before 6.5.0 allows a local attacker with CLI access to perform operations on the Glassfish server directly via a hardcoded password.
An issue was discovered on Momentum Axel 720P 5.1.8 devices. A password of EHLGVG is hard-coded for the root and admin accounts, which makes it easier for physically proximate attackers to login at the console.
TOTOLINK A800R V4.1.2cu.5137_B20200730 was discovered to contain a hardcoded password for root at /etc/shadow.sample.